CORIO CP-900F Refrigerated / heating circulator with an enhanced pump performance and a temperature range up to +200 °C
Performance data depends on the mains voltage in the country of use. Please select:
Country of use | Mains voltage | Plug | JULABO voltage version code
Order No. | 9013706.04 | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +200 °C | |||||||||||||||||||||||||
Temperature stability | ±0.03 °C | |||||||||||||||||||||||||
Heating capacity | 1.8 kW | |||||||||||||||||||||||||
Cooling capacity
* Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.
|
||||||||||||||||||||||||||
Pump capacity flow rate | 8 ... 27 l/min | |||||||||||||||||||||||||
Pump capacity flow pressure | 0.1 ... 0.7 bar | |||||||||||||||||||||||||
Usable bath opening (W x L / D) |
26 x 35 / 20 cm | |||||||||||||||||||||||||
Filling volume | 21 ... 30 l | |||||||||||||||||||||||||
Dimensions (W × L × H) |
39 x 62 x 75 cm |
Product Features
- Models for internal and external applications
- Bright, white, easy to read display
- Very quiet
- Easy pump change-over between internal and external circulation
- External pump connections
- Powerful and infinitely adjustable pressure pump
- USB connection
- RS232 interface for online communication
- Bath lid and drain tap included
- Removable ventilation grid
- Refrigeration unit without side vents
- Unique early warning system for low liquid level
- Class III (FL) according to DIN 12876-1
- Space-saving cooling coil design yields more usable space in the bath tank
Dimensions (W × L × H) |
39 x 62 x 75 cm |
---|---|
Filling volume | 21 ... 30 l |
Weight | 52 kg |
Pump connections | M16x1 male |
Barbed fittings inner diameter | 8/12 mm |
Working temperature range | -38 ... +200 °C |
---|---|
Temperature stability | ±0.03 °C |
Temperature display resolution | 0.01 ... 0.1 °C |
Ambient temperature | +5 ... +40 °C |
Performance data depends on the mains voltage in the country of use. Please select:
Country of use | Mains voltage | Plug | JULABO voltage version code
Heating capacity | 1.8 kW | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
* Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.
|
|||||||||||||||||||||||||||
Pump capacity flow rate | 8 ... 27 l/min | ||||||||||||||||||||||||||
Pump capacity flow pressure | 0.1 ... 0.7 bar | ||||||||||||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||||||||||||
Power | 13 A |
Bath tank | Stainless steel |
---|---|
Bath cover | integrated |
Usable bath opening (W x L / D) |
26 x 35 / 20 cm |
Cooling of compressor | 1-stage Air |
---|
Classification according to DIN12876-1 |
Classification III (FL) |
---|---|
IP Code according to IEC 60529 |
IP 21 |
Pump function | Pressure Pump |
Pump type | Immersion Pump |
Interfaces | RS232 / USB |
---|---|
Temperature control | PID1 |
Absolute temperature calibration | 3 Point Calibration |
Temperature display | LED |
Temperature setting | Keypad |
Electronic Timer hr:min |
0 ... 999 |
9013706.02 | 115V/60Hz (Nema N5-20 Plug) (R449A) |
---|---|
9013706.04 | 200-230V/50-60Hz (UK Plug Type BS1363A) (R449A) |
9013706.05 | 200-230V/50-60Hz (CH Plug Type SEV 1011) (R449A) |
9013706.33 | 200-230V/50-60Hz (Schuko Plug - CEE 7/4 Plug Type F) (R449A) |
9013706.33.chn | 200-230V/50-60Hz (CN Plug) (R449A) |
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male) |
Overview
Contact expertAccessory for CORIO CP-900F
Benefits
-
Condensation protection.
Superb design solution. Integrated ventilation directs air over the bath lid and minimizes condensation. -
Handle with ease.
Makes day-to-day work easy. Comfortably move your JULABO Circulator around by using the ergonomic handles (front and rear). -
Internal. External.
The pump is controlled via a lever located directly below the display. Easily change between internal and external circulation. -
Mobile.
Extra easy handling. Integrated castors for easy repositioning of refrigerated circulators.