SL-14K HighTech SL calibration bath

for working temperatures from +50 °C to +300 °C

JULABO calibration baths are ideal for high precision calibration of sensors, measuring instruments, thermometers, etc. The instruments are certified for application in DKD laboratories and according to the requirements specified by DIN EN ISO 9001:2000.

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
SL-14K
Order No. 9352514.33
Working temperature range +50 ... +300 °C
Temperature stability ±0.005 °C
Heating capacity 3 kW
Pump capacity flow pressure 22 ... 26 l/min
Circulation capacity pressure 0.4 ... 0.7 bar
Usable bath opening
(W x L / D)
12 cm
Filling volume 14 l
Dimensions
(W × L × H)
22 x 46 x 61 cm
Arrange callback

Product Features

  • LCD DIALOG DISPLAY backlit for convenient interactive operation
  • ICC (Intelligent Cascade Control), self-optimizing temperature control
  • TCF Temperature Control Features to optimize the control behavior
  • Integrated programmer for 6 x 60 program steps
  • Highest temperature stability to ±0.005 °C (±0.02 °C at +200 °C)
  • Temperature uniformity better than ±0.01 °C
  • Optional Pt100 sensor for reference temperature measurements
  • Temperature chamber with overflow at maximum liquid level

Technical data for SL-14K

Dimensions and volumes
Dimensions
(W × L × H)
22 x 46 x 61 cm
Filling volume 14 l
Usable immersion depth 31 cm
Weight 20 kg
Temperature values
Working temperature range +50 ... +300 °C
Temperature stability ±0.005 °C
Temperature display resolution 0.01 °C
Ambient temperature 1 +5 ... +40 °C

1 Depending on the ambient temperature and the bath fluid used, it may be necessary to use the cooling coil for temperature applications around +50 °C.

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Heating capacity 3 kW
Pump capacity flow pressure 22 ... 26 l/min
Circulation capacity pressure 0.4 ... 0.7 bar
Maximum suction 0.2 ... 0.4 bar
Viscosity max. 70 cSt
Power consumption 14 A
Bath
Bath tank Stainless steel
Bath cover integrated
Usable bath opening
(W x L / D)
12 cm
Cooling
Cooling coil integrated
Other
Classification
according to DIN12876-1
Classification III (FL)
IP Code
according to IEC 60529
IP 21
Pump type Immersion Pump
Electronics
Interfaces Profibus optional
External pt100 sensor connection integrated
Integrated programmer 6x60 steps
Temperature control ICC
Absolute temperature calibration 3 Point Calibration
Temperature display VFD
Temperature setting Keypad
Available voltage versions
9352514.33 230V/50-60Hz (Schuko Plug - CEE 7/4 Plug Type F)
Included in delivery
Including bath cover with seven openings

Accessory for SL-14K

Downloads for SL-14K

We would also be happy to send you our printed catalogs and brochures by post.

Request brochure

SL-14K Benefits

For flammable bath fluid

Classification III (FL) according to DIN 12876-1

ATC3. Calibration.

‘Absolute Temperature Calibration’ for compensating a physically caused temperature difference, 3-point calibration.

Process. Under control.

Full regulation of the dynamics control, access to all important control parameters for individual process optimization.

100 % Cooling capacity

‘Active Cooling Control’ for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures

Show all 16 benefits