Tubing and insulation

Flexible connection of the application to the temperature control instrument for optimal use in the respective temperature range.

CR tubing (8 mm lD)

Technical Data:

  • Working temperature range: -30 °C to +120 °C
  • Maximum pressure: 1.2 bar
  • Material: Chloroprene
  • Connection: No closure, open tube end
  • Length: Variable
  • External diameter: 10mm
  • Internal …

Order number: 8930008

Details
Metal tubing (M16x1), -100 °C to +350 °C, 1 m

Technical Data:

  • Working temperature range: -100 °C to +350 °C
  • Material: Stainless steel 1.4404
  • Insulation: Special triple insulation. The ends are covered with silicon caps.
  • Connection: M16x1 …

Order number: 8930210

Details
Metal tubing (M16x1), -100 °C to +350 °C, 1.5 m

Technical Data:

  • Working temperature range: -100 °C to +350 °C
  • Material: Stainless steel 1.4404
  • Insulation: Special triple insulation. The ends are covered with silicon caps.
  • Connection: M16x1 …

Order number: 8930211

Details
Metal tubing (M16x1), -100 °C to +350 °C, 3 m

Technical Data:

  • Working temperature range: -100 °C to +350 °C
  • Material: Stainless steel 1.4404
  • Insulation: Special triple insulation. The ends are covered with silicon caps.
  • Connection: M16x1 …

Order number: 8930214

Details
Metal tubing (M16x1), -100 °C to +350 °C, 2 m

Technical Data:

  • Working temperature range: -100 °C to +350 °C
  • Material: Stainless steel 1.4404
  • Insulation: Special triple insulation. The ends are covered with silicon caps.
  • Connection: M16x1 …

Order number: 8930216

Details
Metal tubing (M16x1), -50 °C to +200 °C, 0.5 m

Technical Data:

  • Working temperature range: -50 °C to +200 °C
  • Material: Stainless steel 1.4404
  • Insulation: Special single insulation. The ends are covered with silicon caps.
  • Connection: M16x1 thread …

Order number: 8930220

Details
Metal tubing (M16x1), -50 °C to +200 °C, 1 m

Technical Data:

  • Working temperature range: -50 °C to +200 °C
  • Material: Stainless steel 1.4404
  • Insulation: Special single insulation. The ends are covered with silicon caps.
  • Connection: M16x1 thread …

Order number: 8930221

Details
Metal tubing (M16x1), -50 °C to +200 °C, 1.5 m

Technical Data:

  • Working temperature range: -50 °C to +200 °C
  • Material: Stainless steel 1.4404
  • Insulation: Special single insulation. The ends are covered with silicon caps.
  • Connection: M16x1 thread …

Order number: 8930222

Details
Metal tubing (M16x1), -50 °C to +200 °C, 3 m

Technical Data:

  • Working temperature range: -50 °C to +200 °C
  • Material: Stainless steel 1.4404
  • Insulation: Special single insulation. The ends are covered with silicon caps.
  • Connection: M16x1 thread …

Order number: 8930223

Details
Metal tubing (M16x1), -50 °C to +200 °C, 2 m

Technical Data:

  • Working temperature range: -50 °C to +200 °C
  • Material: Stainless steel 1.4404
  • Insulation: Special single insulation. The ends are covered with silicon caps.
  • Connection: M16x1 thread …

Order number: 8930224

Details
Metal tubing (M24x1,5), -100°C...+350°C, 1m

Technical Data:

  • Working temperature range: -100 °C to +350 °C
  • Material: Stainless steel 1.4404
  • Insulation: Special triple insulation. The ends are covered with silicon caps.
  • Connection: M24x1.5 …

Order number: 8930261

Details
Metal tubing (M24x1,5), -100°C...+350°C, 1,5 m

Technical Data:

  • Working temperature range: -100 °C to +350 °C
  • Material: Stainless steel 1.4404
  • Insulation: Special triple insulation. The ends are covered with silicon caps.
  • Connection: M24x1.5 …

Order number: 8930262

Details
Metal tubing (M24x1,5), -100°C...+350°C, 2m

Technical Data:

  • Working temperature range: -100 °C to +350 °C
  • Material: Stainless steel 1.4404
  • Insulation: Special triple insulation. The ends are covered with silicon caps.
  • Connection: M24x1.5 …

Order number: 8930263

Details
Metal tubing (M24x1,5), -100°C...+350°C, 3 m

Technical Data:

  • Working temperature range: -100 °C to +350 °C
  • Material: Stainless steel 1.4404
  • Insulation: Special triple insulation. The ends are covered with silicon caps.
  • Connection: M24x1.5 …

Order number: 8930264

Details
Metal tubing (M30x1.5), -100°C...+350°C, 1 m

Technical Data:

  • Working temperature range: -100 °C to +350 °C
  • Material: Stainless steel 1.4404
  • Insulation: Special triple insulation. The ends are covered with silicon caps.
  • Connection: M30x1.5 …

Order number: 8930271

Details
This accessory is suitable for:
PRESTO W55
Metal tubing (M30x1,5), -100°C...+350°C, 1.5 m

Technical Data:

  • Working temperature range: -100 °C to +350 °C
  • Material: Stainless steel 1.4404
  • Insulation: Special triple insulation. The ends are covered with silicon caps.
  • Connection: M30x1.5 …

Order number: 8930272

Details
This accessory is suitable for:
PRESTO W55
Metal tubing (M30x1.5), -100°C...+350°C, 2 m

Technical Data:

  • Working temperature range: -100 °C to +350 °C
  • Material: Stainless steel 1.4404
  • Insulation: Special triple insulation. The ends are covered with silicon caps.
  • Connection: M30x1.5 …

Order number: 8930273

Details
This accessory is suitable for:
PRESTO W55
Metal tubing (M30x1.5), -100°C...+350°C, 3 m

Technical Data:

  • Working temperature range: -100 °C to +350 °C
  • Material: Stainless steel 1.4404
  • Insulation: Special triple insulation. The ends are covered with silicon caps.
  • Connection: M30x1.5 …

Order number: 8930274

Details
This accessory is suitable for:
PRESTO W55
Metal tubing (M30x1.5), -100°C...+350°C, 5 m

Technical Data:

  • Working temperature range: -100 °C to +350 °C
  • Material: Stainless steel 1.4404
  • Insulation: Special triple insulation. The ends are covered with silicon caps.
  • Connection: M30x1.5 …

Order number: 8930275

Details
This accessory is suitable for:
PRESTO W55
Metal tubing (M38x1.5), -100°C...+350°C, 1.5 m

Technical Data:

  • Working temperature range: -100 °C to +350 °C
  • Material: Stainless steel 1.4404
  • Insulation: Special triple insulation. The ends are covered with silicon caps.
  • Connection: M38x1.5 …

Order number: 8930282

Details
Additional products
Metal tubing (M38x1.5), -100°C...+350°C, 2 m

Technical Data:

  • Working temperature range: -100 °C to +350 °C
  • Material: Stainless steel 1.4404
  • Insulation: Special triple insulation. The ends are covered with silicon caps.
  • Connection: M38x1.5 …

Order number: 8930283

Details
Additional products
Metal tubing (M38x1.5), -100°C...+350°C, 3 m

Technical Data:

  • Working temperature range: -100 °C to +350 °C
  • Material: Stainless steel 1.4404
  • Insulation: Special triple insulation. The ends are covered with silicon caps.
  • Connection: M38x1.5 …

Order number: 8930284

Details
Additional products
Metal tubing (M38x1.5), -100°C...+350°C, 5 m

Technical Data:

  • Working temperature range: -100 °C to +350 °C
  • Material: Stainless steel 1.4404
  • Insulation: Special triple insulation. The ends are covered with silicon caps.
  • Connection: M38x1.5 …

Order number: 8930285

Details
Additional products
Reinforced tubing (8 mm ID)

Technical Data:

  • Working temperature range: -40°C … +120 °C
  • Material: EDPM
  • Connection: Cable end open
  • Length: variable
  • External Diameter: 13 mm
  • Inner Diameter: 8 mm
  • Thickness: 5 mm
  • Bending …

Order number: 8930308

Details
Reinforced tubing (12 mm ID)

Technical Data:

  • Working temperature range: -40°C … +120 °C
  • Material: EDPM
  • Connector: Cable end open
  • Length: variable
  • Outer Diameter: 19 mm
  • Inner Diameter: 13 mm
  • Thickness: 3 mm
  • Bending radius: …

Order number: 8930312

Details
Reinforced tubing (3/4" ID)

Technical Data:

  • Working temperature range: -40°C … +120 °C
  • Material: EDPM
  • Connector: Cable end open
  • Length: variable
  • Outer Diameter: 27 mm
  • Inner Diameter: 3/4"
  • Thickness: 4 mm
  • Bending radius: 65 …

Order number: 8930319

Details
Reinforced tubing (1" ID)

Technical Data:

  • Working temperature range: -40°C … +120 °C
  • Material: EDPM
  • Connector: Cable end open
  • Length: variable
  • Outer Diameter: 34 mm
  • Inner Diameter: 25 mm
  • Thickness: 4,5 mm
  • Bending radius: …

Order number: 8930325

Details
This accessory is suitable for:
FLW4006 FL4006 VIGORO 5000 VIGORO 7500 VIGORO 10000
Additional products
Reinforced tubing

Reinforced tubing, 1 1/2“ inner dia. (-40 … +120 °C), per meter.

Order number: 8930326

Braided tubing G 3/4“ , 1.5 m

Technical Data:

  • Working temperature range: -30 °C to +100 °C
  • Material: EPDM tubing with stainless steel braiding
  • Connection: 3/4" female thread with cap nut x female thread with cap nut
  • Length: 1.5 …

Order number: 8930331

Details
Braided tubing G 3/4“ , 2 m

Technical Data:

  • Working temperature range: -30 °C to +100 °C
  • Material: EPDM tubing with stainless steel braiding
  • Connection: 3/4" female thread with cap nut x female thread with cap nut
  • Length: 2 m
  • …

Order number: 8930332

Details
Braided tubing G 3/4“, 90°C elbow fitting, 1.5 m

Technical Data:

  • Working temperature range: -30 °C to +100 °C
  • Material: EPDM tubing with stainless steel braiding
  • Connection: 3/4" female thread with cap nut x female thread with cap nut
  • Length: 1.5 …

Order number: 8930341

Details
Braided tubing G 3/4“, 90°C elbow fitting, 2 m

Technical Data:

  • Working temperature range: -30 °C to +100 °C
  • Material: EPDM tubing with stainless steel braiding
  • Connection: 3/4" female thread with cap nut x female thread with cap nut
  • Length: 2 m …

Order number: 8930342

Details
Insulation (14 mm ID)

Technical Data:

  • Temperature range: -50...+100°C
  • Insulation for CR tubing 8 to 10 mm ID
  • Length: variable
  • Insulation thickness: 8 mm
  • Color: Black
…

Order number: 8930410

Details
Tubing insulation (23 mm ID)

Technical Data:

  • Temperature range: -50...+100°C
  • Insulation for reinforced tubing 12 mm ID or 1/2" ID
  • Length: variable
  • Insulation thickness: 12 mm
  • Color: Black
…

Order number: 8930413

Details
Tubing insulation (29 mm ID)

Technical Data:

  • Temperature range: -50...+100°C
  • Insulation for reinforced tubing with 3/4" ID
  • Length: variable
  • Insulation thickness: 12mm
  • Color: Black
…

Order number: 8930419

Details
Tubing insulation (35 mm ID)

Technical Data:

  • Temperature range: -50...+100°C
  • Tubing insulation for reinforced tubing with 1" ID
  • Length: Variable
  • Insulation thickness: 13 mm
  • Color: Black
…

Order number: 8930425

Details
This accessory is suitable for:
FLW4006 FL4006 VIGORO 5000 VIGORO 7500 VIGORO 10000
Additional products
Insulation

Insulation with 48 mm inner dia., for reinforced tubing 1 1/2“ ID, per meter.

Order number: 8930448

Tube clamps

2 Tube clamps, size 2, for CR tubing 10-12 mm and Reinforced tubing 8 mm ID

Order number: 8970481

Tube clamps

2 Tube clamps, size 3, for Reinforced tubing 12 mm or 1/2“ ID

Order number: 8970482

Tube clamps

2 Tube clamps, size 4, for Reinforced tubing 3/4“ ID

Order number: 8970483

Tube clamps

2 Tube clamps, size 5, for Reinforced tubing 1“ ID

Order number: 8970484

This accessory is suitable for:
VIGORO 5000 VIGORO 7500 VIGORO 10000