FL Recirculating Coolers
Chill Environmentally Friendly and Economical
The FL series offers a new generation of chillers for routine cooling applications within the laboratory and industry. The temperature stability of the PID control is ±0.5°C.
All units can easily be cleaned and are provided with a splash water proof keypad with LED temperature indication. On the front of the units there is an RS232 interface as well as an alarm shutdown. The filling port is easily accessible placed on the top under a lift-up cover. Another hinged tray serves as a file for the operating manual or other documents concerning the installation. The removable venting grid allows an easy cleaning of the condenser, the drain tap is easily accessible behind the grid. All models include an easily visible level indication. Another advantage is the venting slots are on the front and rear and therefore the units can be placed directly one beside the other (space saving).
Your advantages
- Ergonomic design and easy operation
- Splash-proof keypad
- Large, bright LED display
- Reliable Microprocessor PID temperature control
- Powerful immersion pumps, suitable for continuous operation
- Permissible temperature in return line +80°C
- Easy filling and Drain tap easily accessible
- Low liquid level protection with optical and audible alarm signal
- Integrated stainless steel bath tanks
- Removable ventilation grid
- Front drain
- No side vents, instruments can be placed right next to other equipment
- RS232 interface for PC connection
- IP class according to IEC 60529: 21
- Alarm output, potential-free change-over contact (max. 30 VA)
- Pressure Indicator
- By-pass valve to adjust pump pressure
- Optical filling level indicator
Product Overview
FL Recirculating up to 1.7 KW Cooling Capacity
compact models with up to 1.7 kW of cooling capacity for installation below a lab bench
The compact FL models are suited for a wide variety of cooling tasks. Installation under a lab bench saves valuable space. 2 variants: Air-cooled (FL) and water-cooled (FLW).
| Model | FL300 | FL601 | FL1201 | FL1701 |
|---|---|---|---|---|
| Order No. | 9 660 003 | 9 661 006 | 9 661 012 | 9 661 017 |
| Working temperature range (°C) | -20 ... +40 | -20 ... +40 | -20 ... +40 | -20 ... +40 |
| Temperature stability (°C) | ±0.5 | ±0.5 | ±0.5 | ±0.5 |
| Cooling capacity (kW) | 0.3 | 0.6 | 1.2 | 1.7 |
| Pump capacity flow rate (l/min) | 15 | 23 | 23 | 23 |
| Pump capacity flow pressure (bar) | 5.1 | 14.5 | 14.5 | 14.5 |
| Model | FL1203 | FL1703 | FLW1701 | FLW1703 |
|---|---|---|---|---|
| Order No. | 9 663 012 | 9 663 017 | 9 671 017 | 9 673 017 |
| Working temperature range (°C) | -20 ... +40 | -20 ... +40 | -20 ... +40 | -20 ... +40 |
| Temperature stability (°C) | ±0.5 | ±0.5 | ±0.5 | ±0.5 |
| Cooling capacity (kW) | 1.2 | 1.7 | 1.7 | 1.7 |
| Pump capacity flow rate (l/min) | 40 | 40 | 23 | 40 |
| Pump capacity flow pressure (psi) | 7.3 ... 43.5 | 7.3 ... 43.5 | 14.5 | 7.3 ... 43.5 |
FL recirculating cooler with up to 4.3 kW of cooling capacity
The FL models shown here have higher cooling capacity, powerful circulating pumps, and internal bath volumes of up to 30 liters. 2 variants: Air-cooled (FL) and water-cooled (FLW).
| Model | FL2503 | FL4003 | FL2506 | FL4006 |
|---|---|---|---|---|
| Order No. | 9 663 025 | 9 663 040 | 9 666 025 | 9 666 040 |
| Working temperature range (°C) | -20 ... +40 | -20 ... +40 | -15 ... +40 | -20 ... +40 |
| Temperature stability (°C) | ±0.5 | ±0.5 | ±0.5 | ±0.5 |
| Cooling capacity (kW) | 2.5 | 4 | 2.5 | 4 |
| Pump capacity flow rate (l/min) | 40 | 40 | 60 | 60 |
| Pump capacity flow pressure (psi) | 7.3 ... 43.5 | 7.3 ... 43.5 | 7.3 ... 87 | 7.3 ... 87 |
| Model | FLW2503 | FLW4003 | FLW2506 | FLW4006 |
|---|---|---|---|---|
| Order No. | 9 673 025 | 9 673 040 | 9 676 025 | 9 676 040 |
| Working temperature range (°C) | -20 ... +40 | -20 ... +40 | -15 ... +40 | -15 ... +40 |
| Temperature stability (°C) | ±0.5 | ±0.5 | ±0.5 | ±0.5 |
| Cooling capacity (kW) | 2.7 | 4.3 | 2.5 | 4 |
| Pump capacity flow rate (l/min) | 40 | 60 | 60 | |
| Pump capacity flow pressure (psi) | 7.3 ... 43.5 | 7.3 ... 87 | 7.3 ... 87 |
FL recirculating cooler with up to 20 kW of cooling capacity
Models with particularly high power reserves
The powerful FL models are suitable for a wide range of cooling tasks in industrial environments, such as removal of large process heat. 2 variants: Air-cooled (FL) and water-cooled (FLW).
| Model | FL7006 | FL11006 | FL20006 | FLW7006 |
|---|---|---|---|---|
| Order No. | 9 666 070 | 9 666 110 | 9 666 200 | 9 676 070 |
| Working temperature range (°C) | -20 ... +40 | -20 ... +40 | -25 ... +40 | -20 ... +40 |
| Temperature stability (°C) | ±0.5 | ±0.5 | ±0.5 | ±0.5 |
| Cooling capacity (kW) | 7 | 10.3 | 20 | 7.4 |
| Pump capacity flow rate (l/min) | 60 | 60 | 80 | 60 |
| Pump capacity flow pressure (psi) | 7.3 ... 87 | 7.3 ... 87 | 11.6 ... 87 | 7.3 ... 87 |