Forte HT High Temperature Circulators
for working temperatures from +70 °C to +400 °C
High temperature circulators of the FORTE HT series are designed for temperature control in closed external systems. These compact units have a closed design that prevents the escape of oil vapors especially at high temperatures.
Product Features
- Integrated programmer for 6 x 60 program steps
- Strong pumping capacity 18 l/min - 1.2 bar max
- Automatic air-purge allows easy filling
- Electronic level indication
- Self-optimizing ICC temperature controller
Product Overview
Forte HT high temperature circulators
2-zone technique for working temperatures up to 400 °C
JULABO High Temperature Circulators can be used for temperature applications up to +400 °C. The units provide powerful heating capacities for shortest heat-up times and rapid compensation of exothermic and endothermic reactions. The closed construction prevents oil fumes even at high temperatures. The units provide automatic heat-up and cracking protection to ensure long life-time of the bath fluid. The filling system automatically purges the fluid system of air. Units with model designation ‚C.U.‘ are equipped with a powerful cooling unit for tap water connection. This allows for temperature applications already at +20 °C and for rapid cooling. Typical applications: Reactors, autoclaves, distillation columns, miniplant installations, pilot plants and production facilities.
| Model | Add to compare HT30-M1 |
Add to compare HT60-M2 |
Add to compare HT60-M3 |
|---|---|---|---|
| Working temperature range (°C) | 70 ... 400 | 70 ... 400 | 70 ... 400 |
| Temperature stability (°C) | ±0.01 ... ±0.1 | ±0.01 ... ±0.1 | ±0.01 ... ±0.1 |
| Heating capacity (kW) | 3 | 6 | |
| Pump capacity flow rate (l/min) | 14 ... 18 | 14 ... 18 | |
| Pump capacity pressure (psi) | 11.6 ... 17.4 | 11.6 ... 17.4 |
Forte HT with cooling unit
2-zone technique for working temperatures up to 400 °C
JULABO high-temperature circulators make temperature applications up to +400 °C possible. Models with the type suffix “C.U.” have a powerful cooling unit for connection of tap water. This makes temperature applications from +20 °C and quick cooling phases possible. Typical applications are reactors, autoclaves, distillation columns and mini-plant, technical or production facilities.
| Model | Add to compare HT30-M1-C.U. |
Add to compare HT60-M2-C.U. |
Add to compare HT60-M3-C.U. |
|---|---|---|---|
| Working temperature range (°C) | 40 ... 400 | 40 ... 400 | 40 ... 400 |
| Temperature stability (°C) | ±0.01 ... ±0.1 | ±0.01 ... ±0.1 | ±0.01 ... ±0.1 |
| Heating capacity (kW) | 3 | 6 | |
| Pump capacity flow rate (l/min) | 14 ... 18 | 14 ... 18 | |
| Pump capacity pressure (psi) | 11.6 ... 17.4 | 11.6 ... 17.4 |