PRESTO W50 Process system
Water-cooled process system down to -50 °C
The rapid compensation of reactions even at higher ambient temperatures is the domain of the water-cooled W50 units. High heating and cooling capacity paired with powerful pumps.
The highly dynamic temperature control systems PRESTO are designed for high-precision temperature control for a wide range of applications such as reactor vessels or material stress tests. Moreover, by using efficient components, the process systems can compensate exothermic and endothermic reactions exceptionally fast. Permanent internal monitoring and self-lubricating pumps ensure a long life-time. In addition, numerous interfaces offer many remote control possibilities across networks or for integration into higher-level control systems.
Performance data depends on the mains voltage in the country of use. Please select:
| Order number including voltage version | see refrigerant variants |
|---|---|
| Working temperature range | -50 ... +250 °C |
| Temperature stability | ±0.05 ... ±0.1 °C |
| Heating capacity | 6 kW |
| Pump capacity flow rate | 0 ... 80 l/min |
| Pump capacity pressure | 0.1 ... 3 bar |
|
Total dimensions
(W × L × H) |
53 x 66.5 x 126 cm |
Product Features
- Cooling capacity up to 7.5 kW
- Temperature stability ±0.05 °C ... ±0.1 °C
- External Pt100 sensor connection
- Analog connections, RS485, Profibus DP (accessory)
- Second external Pt100 sensor connection (accessory)
- Built-in 5.7’’ industrial color touchscreen
- Alarm output
- Heating capacity 12 kW
- Pump pressure up to 3 bar, max. flow rate 80 l/min
- Heating capacity 6 kW
Technical data for PRESTO W50
|
Total dimensions (W × L × H) |
53 x 66.5 x 126 cm |
|---|---|
| Internal usable expansion volume | 7.5 l |
| Minimal process volume | 7.5 l |
| Active heat exchanger volume | 3.5 l |
| Weight | 210 kg |
| Pump connections | M30x1.5 male |
| Cooling Water Connection | G¾ in |
| Working temperature range | -50 ... +250 °C |
|---|---|
| Temperature stability | ±0.05 ... ±0.1 °C |
| Setting the resolution of the temperature display | 0.01 °C |
| Temperature display resolution | 0.01 °C |
| Ambient temperature | +5 ... +40 °C |
Performance data depends on the mains voltage in the country of use. Please select:
| Heating capacity | 6 kW | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Pump capacity flow rate | 0 ... 80 l/min | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Pump capacity pressure | 0.1 ... 3 bar | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Viscosity max. | 50 cSt | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Power consumption | 16 A | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Cooling of compressor | 1-stage Water |
|---|---|
| Cooling water pressure max. | 6 bar |
| Max. heat dissipated by unit into cooling water | 13 kW |
| to provide full cooling capacity according to catalog values | |
| Cooling water temperature range | 10 ... 15 °C |
|---|---|
| Cooling water difference pressure | 1.5 ... 6 bar |
| Cooling water consumption 1 | 8 ... 12 l/min |
|
1 Cooling water consumption may vary outside recommended cooling water properties. |
|
| Cooling water temperature range | 5 ... 35 °C |
|---|---|
| Cooling water difference pressure 2 | 0.5 ... 6 bar |
|
2 At cooling water temperatures of 25 °C and higher, the minimum differential pressure is 1 bar. |
|
| Sound pressure level | 65 dB(A) |
|---|---|
| Classification according to DIN12876-1 |
Classification III (FL) |
| IP Code according to IEC 60529 |
IP 20 |
| Pump type | Centrifugal Pump |
| Interfaces | Alarm output / Ethernet / Modbus TCP/IP / Profibus optional / REG/EPROG optional / RS232 / RS485 optional / SD memory card / Standby-Input optional / USB |
|---|---|
| External pt100 sensor connection | integrated |
| 2nd external Pt100 sensor connection | accessory |
| Integrated programmer | 8x60 steps |
| Temperature control | ICC |
| Absolute temperature calibration | 3 Point Calibration |
| Temperature display | 5.7" TFT Touchscreen |
| Temperature setting | Touchscreen |
| 9421502.07 | 400V 3PNPE 50Hz (Plug 16A CEE) (R452A) |
|---|---|
| 9421502.S1.07 | 400V 3PNPE 50Hz (Plug 16A CEE) (R449A) |
| 9421502.06 | 230V 3PPE 50Hz (Plug 32A CEE) (R452A) |
| 9421502.16 | 208-220V 3PPE 60Hz (Without Plug) (R507) |
| 9421502.S1.16 | 208-220V 3PPE 60Hz (Without Plug) (R449A) |
Accessory for PRESTO W50
Downloads for PRESTO W50
We would also be happy to send you our printed catalogs and brochures by post.
Request brochurePRESTO W50 Benefits
Touch display. Perfect operation.
With the touch display, the user always has an overview of all values and functions. The intuitive and multilingual menu structure enables perfect control.
Convenience for several users
Administrator level for customizing instrument settings, user levels with limited permissions for fast and safe defined access, password protection, all levels adjustable
100 % Cooling capacity
‘Active Cooling Control’ for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures
Intelligent temperature control.
Intelligent cascade control - automatic and self-optimizing adaptation of the PID control parameters with external stability of +/- 0.05 °C.
Related Products
Products with similar properties