Cryo-Compact Circulators

for working temperatures from -40 °C to +200 °C

The new CF series offers compact refrigerated/heating circulators. With small overall dimensions the units can even be placed on a very small surface or within a complex installation. All models offer a heating capacity of 2 kW and safety class III according to DIN12876-1. The maximum ambient temperature of +40°C as well as a ventilation air cooling allow installing the units very closely side by side with other units or directly under a fume hood.

Furthermore all the models feature pump connections for external temperature applications and a bath opening for temperature control of small objects directly in the circulator bath. Wetted parts are made of high quality stainless steel or plastic. The instruments provide a reliable Microprocessor electronics with high temperature stability as well as warning and safety functions.

Product Features

  • Ergonomic design and easy operation
  • Small overall dimensions for lowest space requirement
  • Splash-proof keypad
  • Extra bright displays, easy to read from a distance
  • Pump connections for external temperature applications
  • Bath opening for temperature control of small objects in the bath
  • Front drain

Product Overview

Economy Cryo-Compact Circulators

The basis for routine work and standard tasks in the laboratory

The Cryo-Compact Circulators of the CF Series provide powerful cooling and heating capabilities in a space-saving, compact design. The instru-ments feature 2 kW heating capacity and classification III according to DIN 12876-1. The Cryo-Compact Circulators have pump connections for external temperature control applications and a bath opening for tem-perature control of small objects.

Model
Add to compare
CF30
Add to compare
CF40
Working temperature range (°C) -30 ... 150 -40 ... 150
Temperature stability (°C) ±0.03 ±0.03
Cooling capacity (kW) 0.32 0.47
Heating capacity (kW) 2 2
Pump capacity flow rate (l/min) 15 15
Pump capacity pressure (psi) 5.1 5.1

HighTech Cryo-Compact Circulators

The top class for demanding tasks in any environment

The Cryo-Compact Circulators of the CF Series provide powerful cooling and heating capabilities in a space-saving, compact design. The instruments feature 2 kW heating capacity and classification III according to DIN 12876-1. The Cryo-Compact Circulators have pump connections for external temperature control applications and a bath opening for tem-perature control of small objects.

Model
Add to compare
CF31
Add to compare
CF41
Working temperature range (°C) -30 ... 200 -40 ... 200
Temperature stability (°C) ±0.02 ±0.02
Cooling capacity (kW) 0.32 0.47
Heating capacity (kW) 2 2
Pump capacity flow rate (l/min) 22 ... 26 22 ... 26
Pump capacity pressure (psi) 5.8 ... 10.2 5.8 ... 10.2