AWC100 Air-to-Water Recirculating Cooler
Extremely compact Recirculating Cooler to remove small heat loads.
JULABO's Air to Water Recirculating Cooler AWC100 is an extremely compact solution, designed to remove small heat loads from external systems such as from Peltier-elements. The highly competitively priced AWC100 features a compact footprint and is designed specifically for applications where cooling water can be above ambient and where temperature control is secondary.
Request a quoteThe ventilator speed can be increased by changing the switch for booster cooling on the rear of the unit. Stage 0: normal cooling capacity, virtually noiseless. Stage 1: higher cooling capacity, higher ventilator speed.

Order No. | 9 630 100.99 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | +20 ... +40 °C | |||||||||||
Cooling capacity 1
(Medium: Ethanol) |
|
|
||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||
|
||||||||||||
Cooling capacity 2
(Medium: Ethanol) |
|
|
||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||
|
||||||||||||
Pump capacity flow rate | 3.5 l/min | |||||||||||
Pump capacity flow pressure | 7.1 psi | |||||||||||
Filling volume | 0.9 l | |||||||||||
Dimensions (W × L × H) |
7.9 x 13.4 x 11.8 in. |
Order No. | 9 630 100.99 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | +20 ... +40 °C | |||||||||||
Cooling capacity 1
(Medium: Ethanol) |
|
|
||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||
|
||||||||||||
Cooling capacity 2
(Medium: Ethanol) |
|
|
||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||
|
||||||||||||
Pump capacity flow rate | 3.5 l/min | |||||||||||
Pump capacity flow pressure | 7.1 psi | |||||||||||
Filling volume | 0.9 l | |||||||||||
Dimensions (W × L × H) |
7.9 x 13.4 x 11.8 in. |
Order No. | 9 630 100.99 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | +20 ... +40 °C | |||||||||||
Cooling capacity 1
(Medium: Ethanol) |
|
|
||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||
|
||||||||||||
Cooling capacity 2
(Medium: Ethanol) |
|
|
||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||
|
||||||||||||
Pump capacity flow rate | 3.5 l/min | |||||||||||
Pump capacity flow pressure | 7.1 psi | |||||||||||
Filling volume | 0.9 l | |||||||||||
Dimensions (W × L × H) |
7.9 x 13.4 x 11.8 in. |
Product Features
- Hassle-free operation
- Connect, switch on and get started
- Small footprint
- Virtually noiseless
- Economical
Dimensions (W × L × H) |
7.9 x 13.4 x 11.8 in. |
---|---|
Filling volume | 0.9 l |
Weight | 21.4 lbs |
Pump connections | M10x1 |
Pump connections | M10x1 |
Barbed fittings inner diameter | 8/10 mm |
Working temperature range | +20 ... +40 °C |
---|---|
Ambient temperature | 5 ... 35 °C |
Cooling capacity 1
(Medium: Ethanol) |
|
|
|||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
(Medium: Ethanol) |
|||||||||||||
|
|||||||||||||
Cooling capacity 2
(Medium: Ethanol) |
|
|
|||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||
|
|||||||||||||
Pump capacity flow rate | 3.5 l/min | ||||||||||||
Pump capacity flow pressure | 7.1 psi | ||||||||||||
Power | 0.4 A |
Cooling capacity 1
(Medium: Ethanol) |
|
|
|||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
(Medium: Ethanol) |
|||||||||||||
|
|||||||||||||
Cooling capacity 2
(Medium: Ethanol) |
|
|
|||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||
|
|||||||||||||
Pump capacity flow rate | 3.5 l/min | ||||||||||||
Pump capacity flow pressure | 7.1 psi | ||||||||||||
Power | 0.3 A |
Cooling capacity 1
(Medium: Ethanol) |
|
|
|||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
(Medium: Ethanol) |
|||||||||||||
|
|||||||||||||
Cooling capacity 2
(Medium: Ethanol) |
|
|
|||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||
|
|||||||||||||
Pump capacity flow rate | 3.5 l/min | ||||||||||||
Pump capacity flow pressure | 7.1 psi | ||||||||||||
Power | 0.3 A |
Cooling of compressor | Air |
---|
Sound pressure level | 55 dbA |
---|---|
IP Code according to IEC 60529 |
IP 21 |
Pump type | Centrifugal Pump |
100-230V/50-60Hz Multiple Plugs (EU / US / GB / CH - Plug) | 9630100.99 |
---|
2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) |
Accessory for AWC100
Benefits
-
100% Checked.
100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory. -
Green technology.
Development consistently applied environmentally friendly materials and technologies. -
JULABO. Quality.
Highest standards of quality for a long product life. -
Quick start.
Individual JULABO consultation and comprehensive manuals at your disposal.