FL4006 Powerful model in tower version

The FL models shown here have higher cooling capacity, powerful circulating pumps, and internal bath volumes of up to 30 liters. 2 variants: Air-cooled (FL) and water-cooled (FLW).

Request a quote
Data at mains voltage / frequency:
400V/3PNPE/50Hz (Plug 16A CEE)
FL4006
Order No. 9 666 040
Working temperature range -20 ... +40 °C
Temperature stability ±0.5 °C
Cooling capacity
°C
kW
20 10 0 -10 -20
4 2.9 1.9 0.9 0.05
Cooling capacity
°C 20 10 0 -10 -20
kW 4 2.9 1.9 0.9 0.05
Pump capacity flow rate 60 l/min
Pump capacity flow pressure 0.5 ... 6 bar
Filling volume 24 ... 30 l
Dimensions
(W × L × H)
60 x 76 x 115 cm
FL4006
Order No. 9 666 040
Working temperature range -20 ... +40 °C
Temperature stability ±0.5 °C
Cooling capacity
°C
kW
20 10 0 -10 -20
4 2.9 1.9 0.9 0.05
Cooling capacity
°C 20 10 0 -10 -20
kW 4 2.9 1.9 0.9 0.05
Pump capacity flow rate 60 l/min
Pump capacity flow pressure 0.5 ... 6 bar
Filling volume 24 ... 30 l
Dimensions
(W × L × H)
60 x 76 x 115 cm

Product Features

  • Ergonomic design and easy operation
  • Splash-proof keypad
  • Large, bright LED display
  • Reliable Microprocessor PID temperature control
  • Precise PID temperature control
  • Powerful immersion pumps, suitable for continuous operation
  • Permissible temperature in return line +80°C
  • Easy filling from the top with hinged protective lid
  • Low liquid level protection with optical and audible alarm signal
  • Integrated stainless steel bath tanks
  • Front drain
  • No side vents, instruments can be placed right next to other equipment
  • RS232 interface for PC connection
  • IP class according to IEC 60529: 21
  • Alarm output, potential-free change-over contact (max. 30 VA)
  • Pressure Indicator
Dimensions and volumes
Dimensions
(W × L × H)
60 x 76 x 115 cm
Filling volume 24 ... 30 l
Weight 157 kg
Pump connections G1¼" male
Barbed fittings inner diameter 1"
Temperature values
Working temperature range -20 ... +40 °C
Temperature stability ±0.5 °C
Setting the resolution of the temperature display 0.1 °C
Temperature display resolution 0.1 °C
Ambient temperature 5 ... 40 °C
Return flow temperature max. 80 °C
Data at mains voltage / frequency:
400V/3PNPE/50Hz (Plug 16A CEE)
Performance values
Cooling capacity
°C
kW
20 10 0 -10 -20
4 2.9 1.9 0.9 0.05
Cooling capacity
°C 20 10 0 -10 -20
kW 4 2.9 1.9 0.9 0.05
Pump capacity flow rate 60 l/min
Pump capacity flow pressure 0.5 ... 6 bar
Refrigerant stage 1
Refrigerant R449A
Global Warming Potential for R449A 1397
Filling volume 1800 g
Carbon dioxide equivalent 2.515 t
Power 16 A
Performance values
Cooling capacity
°C
kW
20 10 0 -10 -20
4 2.9 1.9 0.9 0.05
Cooling capacity
°C 20 10 0 -10 -20
kW 4 2.9 1.9 0.9 0.05
Pump capacity flow rate 60 l/min
Pump capacity flow pressure 0.5 ... 6 bar
Refrigerant stage 1
Refrigerant R452A
Global Warming Potential for R452A 2140
Filling volume 2220 g
Carbon dioxide equivalent 4.751 t
Power 12 A
Bath
Bath tank Stainless steel
Cooling
Cooling of compressor 1-stage Air
Other
Sound pressure level 67 dbA
Classification
according to DIN12876-1
Classification I (NFL)
IP Code
according to IEC 60529
IP 21
Pump type Immersion Pump
Electronics
Temperature control PID1
Temperature display LED
Temperature setting Keypad
Available voltage versions
230V/3PPE/60Hz Without Plug 9666040.16
400V/3PNPE/50Hz Plug 16A CEE 9666040.07
Included in delivery
2 each barbed fittings for tubing 1" inner dia (pumpconnections G1 1/4" male)

Accessory for FL4006

We would also be happy to send you our printed catalogs and brochures by post.


Request brochure

Benefits

  • 100% geprüft
    100% Checked.
    100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.
  • Blatt wächst in einer Glühbirne
    Green technology.
    Development consistently applied environmentally friendly materials and technologies.
  • Made in Germany
    JULABO. Quality.
    Highest standards of quality for a long product life.
  • Quickstart
    Quick start.
    Individual JULABO consultation and comprehensive manuals at your disposal.