FCW600S Chiller

with increased pump capacity

Recirculating coolers of the FC series with an increased pump capacity are available for applications with large volumes. Thanks to their integrated heating, they have an increased working temperature range and operate very precisely with a temperature stability of ±0.2 °C.

Data at mains voltage / frequency:
230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F)
FCW600S
Order No. 9 601 063
Working temperature range -10 ... +80 °C
Temperature stability ±0.2 °C
Heating capacity 1.2 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 10 5 0 -10
0.5 0.37 0.3 0.24 0.1
Cooling capacity
(Medium: Ethanol)
°C 20 10 5 0 -10
kW 0.5 0.37 0.3 0.24 0.1
Pump capacity flow rate 22 l/min
Pump capacity flow pressure 1.2 bar
Filling volume 6 ... 8 l
Dimensions
(W × L × H)
35 x 54 x 49 cm
FCW600S
Order No. 9 601 063
Working temperature range -10 ... +80 °C
Temperature stability ±0.2 °C
Heating capacity 1.2 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 10 5 0 -10
0.5 0.37 0.3 0.24 0.1
Cooling capacity
(Medium: Ethanol)
°C 20 10 5 0 -10
kW 0.5 0.37 0.3 0.24 0.1
Pump capacity flow rate 22 l/min
Pump capacity flow pressure 1.2 bar
Filling volume 6 ... 8 l
Dimensions
(W × L × H)
35 x 54 x 49 cm
Arrange callback Accessory

Product Features

  • Adjustable ratio for feed/return temperatures
  • Easy filling system located at the front
  • Activation of pump for filling
  • Bright MULTI-DISPLAY (LED)
  • Upper and lower temperature warning functions with interval tone
  • Integrated freezing protection and dry-running protection
  • Rapid and easy operation via seamless, splash-proof keypad
  • Liquid level indication on the front
  • Self-test, reciprocal sensor monitoring, pump motor and compressor overload protection
  • Complete shut-down with audible signal in case of an alarm
  • Removable venting grid for simplified removal of dust
  • RS232 interface for PC connection
  • High temperature stability
  • Integrated heater with 1.2 kW capacity
Dimensions and volumes
Dimensions
(W × L × H)
35 x 54 x 49 cm
Filling volume 6 ... 8 l
Weight 45 kg
Pump connections M16x1
Cooling Water Connection G¾ in
Barbed fittings inner diameter 8/12 mm
Temperature values
Working temperature range -10 ... +80 °C
Temperature stability ±0.2 °C
Temperature display resolution 0.1 °C
Ambient temperature 5 ... 40 °C
Data at mains voltage / frequency:
230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F)
Performance values
Heating capacity 1.2 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 10 5 0 -10
0.5 0.37 0.3 0.24 0.1
Cooling capacity
(Medium: Ethanol)
°C 20 10 5 0 -10
kW 0.5 0.37 0.3 0.24 0.1
Pump capacity flow rate 22 l/min
Pump capacity flow pressure 1.2 bar
Refrigerant stage 1
Refrigerant R134a
Global Warming Potential for R134a 1430
Filling volume 340 g
Carbon dioxide equivalent 0.486 t
Power 8 A
Performance values
Heating capacity 1.2 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 10 5 0 -10
0.5 0.37 0.3 0.24 0.1
Cooling capacity
(Medium: Ethanol)
°C 20 10 5 0 -10
kW 0.5 0.37 0.3 0.24 0.1
Pump capacity flow rate 22 l/min
Pump capacity flow pressure 1.2 bar
Refrigerant stage 1
Refrigerant R134a
Global Warming Potential for R134a 1430
Filling volume 340 g
Carbon dioxide equivalent 0.486 t
Power 8 A
Bath
Bath tank Stainless steel
Cooling
Cooling of compressor 1-stage Water
Cooling water pressure max. 6 bar
Cooling water difference pressure 3.5 ... 6 bar
Cooling water temperature max. 20 °C
Other
Sound pressure level 54 dbA
Classification
according to DIN12876-1
Classification III (FL)
IP Code
according to IEC 60529
IP 21
Pump type Immersion Pump
Electronics
Digital interface RS232 / Profibus optional / Alarm output / Standby-Input
External pt100 sensor connection not available
Temperature control PID1
Temperature display 2x LED
Temperature setting Keypad
Available voltage versions
230V/60Hz Nema N6-20 Plug 9601063.13
230V/50Hz Schuko Plug - CEE 7/4 Plug Type F 9601063.03
Included in delivery
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male)

Accessory for FCW600S

Contact expert

We would also be happy to send you our printed catalogs and brochures by post.


Request brochure

Benefits

  • 100% geprüft
    100% Checked.
    100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.
  • Blatt wächst in einer Glühbirne
    Green technology.
    Development consistently applied environmentally friendly materials and technologies.
  • ACC
    100 % Cooling capacity
    ‘Active Cooling Control’ for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures
  • S3
    For flammable bath fluid
    Classification III (FL) according to DIN 12876-1