FC1200 Chiller

Chiller for heating and cooling tasks

The recirculating coolers of the FC series are characterized by an increased working temperature range thanks to their integrated heating. They operate very precisely with a temperature stability of ±0.2 °C.

Request a quote
Data at mains voltage / frequency:
230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F)
FC1200
Order No. 9 600 120
Working temperature range -20 ... +80 °C
Temperature stability ±0.2 °C
Heating capacity 1.2 kW
Cooling capacity
°C
kW
20 10 5 0 -10
1.3 0.95 0.75 0.66 0.37
Cooling capacity
°C 20 10 5 0 -10
kW 1.3 0.95 0.75 0.66 0.37
Pump capacity flow rate 20 l/min
Pump capacity flow pressure 0.5 bar
Filling volume 8 ... 11 l
Dimensions
(W × L × H)
46 x 61 x 49 cm
FC1200
Order No. 9 600 120
Working temperature range -20 ... +80 °C
Temperature stability ±0.2 °C
Heating capacity 1.2 kW
Cooling capacity
°C
kW
20 10 5 0 -10
1.3 0.95 0.75 0.66 0.37
Cooling capacity
°C 20 10 5 0 -10
kW 1.3 0.95 0.75 0.66 0.37
Pump capacity flow rate 20 l/min
Pump capacity flow pressure 0.5 bar
Filling volume 8 ... 11 l
Dimensions
(W × L × H)
46 x 61 x 49 cm
FC1200
Order No. 9 600 120
Working temperature range -20 ... +80 °C
Temperature stability ±0.2 °C
Heating capacity 1.2 kW
Cooling capacity
°C
kW
20 10 5 0 -10
1.3 0.95 0.75 0.66 0.37
Cooling capacity
°C 20 10 5 0 -10
kW 1.3 0.95 0.75 0.66 0.37
Pump capacity flow rate 20 l/min
Pump capacity flow pressure 0.5 bar
Filling volume 8 ... 11 l
Dimensions
(W × L × H)
46 x 61 x 49 cm

Product Features

  • Adjustable ratio for feed/return temperatures
  • Easy filling system located at the front
  • Activation of pump for filling
  • Bright MULTI-DISPLAY (LED)
  • Upper and lower temperature warning functions with interval tone
  • Integrated freezing protection and dry-running protection
  • Rapid and easy operation via seamless, splash-proof keypad
  • Liquid level indication on the front
  • Self-test, reciprocal sensor monitoring, pump motor and compressor overload protection
  • Complete shut-down with audible signal in case of an alarm
  • Removable venting grid for simplified removal of dust
  • RS232 interface for PC connection
  • High temperature stability
  • Integrated heater with 1.2 kW capacity
  • Pressure Indicator
Dimensions and volumes
Dimensions
(W × L × H)
46 x 61 x 49 cm
Filling volume 8 ... 11 l
Weight 65 kg
Pump connections M16x1 male
Barbed fittings inner diameter 8/12 mm
Temperature values
Working temperature range -20 ... +80 °C
Temperature stability ±0.2 °C
Temperature display resolution 0.1 °C
Ambient temperature 5 ... 40 °C
Data at mains voltage / frequency:
230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F)
Performance values
Heating capacity 1.2 kW
Cooling capacity
°C
kW
20 10 5 0 -10
1.3 0.95 0.75 0.66 0.37
Cooling capacity
°C 20 10 5 0 -10
kW 1.3 0.95 0.75 0.66 0.37
Pump capacity flow rate 20 l/min
Pump capacity flow pressure 0.5 bar
Refrigerant stage 1
Refrigerant R134a
Global Warming Potential for R134a 1430
Filling volume 450 g
Carbon dioxide equivalent 0.644 t
Power 7 A
Performance values
Heating capacity 1.2 kW
Cooling capacity
°C
kW
20 10 5 0 -10
1.3 0.95 0.75 0.66 0.37
Cooling capacity
°C 20 10 5 0 -10
kW 1.3 0.95 0.75 0.66 0.37
Pump capacity flow rate 20 l/min
Pump capacity flow pressure 0.5 bar
Refrigerant stage 1
Refrigerant R134a
Global Warming Potential for R134a 1430
Filling volume 450 g
Carbon dioxide equivalent 0.644 t
Power 7 A
Performance values
Heating capacity 1.2 kW
Cooling capacity
°C
kW
20 10 5 0 -10
1.3 0.95 0.75 0.66 0.37
Cooling capacity
°C 20 10 5 0 -10
kW 1.3 0.95 0.75 0.66 0.37
Pump capacity flow rate 20 l/min
Pump capacity flow pressure 0.5 bar
Refrigerant stage 1
Refrigerant R134a
Global Warming Potential for R134a 1430
Filling volume 450 g
Carbon dioxide equivalent 0.644 t
Power 7 A
Bath
Bath tank Stainless steel
Cooling
Cooling of compressor 1-stage Air
Other
Sound pressure level 53 dbA
Classification
according to DIN12876-1
Classification III (FL)
IP Code
according to IEC 60529
IP 21
Pump type Immersion Pump
Electronics
Digital interface RS232 / Profibus optional / Alarm output / Standby-Input
External pt100 sensor connection not available
Temperature control PID1
Temperature display 2x LED
Temperature setting Keypad
Available voltage versions
230V/50Hz Schuko Plug - CEE 7/4 Plug Type F 9600120.03
230V/50Hz UK Plug Type BS1363A 9600120.04
230V/50Hz CH Plug Type SEV 1011 9600120.05
Included in delivery
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male)

Accessory for FC1200

We would also be happy to send you our printed catalogs and brochures by post.


Request brochure

Benefits

  • PID2
    Precise
    PID Temperature control with set control parameters, temperature stability ±0.02...±0.2 °C
  • Made in Germany
    JULABO. Quality.
    Highest standards of quality for a long product life.
  • Blatt wächst in einer Glühbirne
    Green technology.
    Development consistently applied environmentally friendly materials and technologies.
  • network
    Satisfied customers.
    11 subsidiaries and more than 100 partners worldwide guarantee fast and qualified JULABO support.