FC Chiller
Chillers for heating and cooling tasks
FC models offer high temperature stability and also feature integrated heating. 2 variants: Air-cooled (FC) and water-cooled (FCW).
The JULABO FC recirculating coolers impress with their compact design that makes setup under a lab bench possible. The bright MULTI-DISPLAY (LED) is easy to read even at a distance and provides all the important information about actual and setpoint values. The automatic self-test at switch on, sensor operation monitoring, pump and compressor protection and a full unit shut-off in case of alarm provide more safety. High/low temperature warning features also ensure optimal protection, as does the freeze and dry running protection. For your application these advantages mean a consistent working temperature, uniform pressure in the circulating pump and no contamination in the cooling circuit.
Product Features
- RS232 interface for PC connection
- Adjustable ratio for feed/return temperatures
- Easy filling system located at the front
- Bright MULTI-DISPLAY (LED)
- Upper and lower temperature warning functions with interval tone
- Integrated freezing protection and dry-running protection
- Rapid and easy operation via seamless, splash-proof keypad
- Liquid level indication on the front
- Self-test, reciprocal sensor monitoring, pump motor and compressor overload protection
- Complete shut-down with audible signal in case of an alarm
- High temperature stability
- Integrated heater with 1.2 kW capacity
- Pressure Indicator
- Activation of pump for filling
- removable venting grid for simplified removal of dust
Product Overview
FC chiller
Chiller for heating and cooling tasks
The recirculating coolers of the FC series are characterized by an increased working temperature range thanks to their integrated heating. They operate very precisely with a temperature stability of ±0.2 °C.
| Model | Add to compare FC600 |
Add to compare FCW600 |
Add to compare FC1200 |
Add to compare FC1600 |
|---|---|---|---|---|
| Working temperature range (°C) | -20 ... 80 | -20 ... 80 | -20 ... 80 | -20 ... 80 |
| Temperature stability (°C) | ±0.2 | ±0.2 | ±0.2 | ±0.2 |
| Cooling capacity (kW) | 0.6 | 0.6 | 1.3 | 1.65 |
| Heating capacity (kW) | 1.2 | 1.2 | 1.2 | 1.2 |
| Pump capacity flow rate (l/min) | 20 | 20 | 20 | 20 |
| Pump capacity pressure (bar) | 0.5 | 0.5 | 0.5 | 0.5 |
FC-S chiller
with increased pump capacity
Recirculating coolers of the FC series with an increased pump capacity are available for applications with large volumes. Thanks to their integrated heating, they have an increased working temperature range and operate very precisely with a temperature stability of ±0.2 °C.
| Model | Add to compare FC600S |
Add to compare FCW600S |
Add to compare FC1200S |
Add to compare FC1600S |
|---|---|---|---|---|
| Working temperature range (°C) | -10 ... 80 | -10 ... 80 | -15 ... 80 | -15 ... 80 |
| Temperature stability (°C) | ±0.2 | ±0.2 | ±0.2 | ±0.2 |
| Cooling capacity (kW) | 0.5 | 0.5 | 1.2 | 1.55 |
| Heating capacity (kW) | 1.2 | 1.2 | 1.2 | 1.2 |
| Pump capacity flow rate (l/min) | 22 | 22 | 22 | 22 |
| Pump capacity pressure (bar) | 1.2 | 1.2 | 1.2 | 1.2 |
FC-T chiller
with highest pump capacity as well as Pt100 and analog connection
FC recirculating coolers with a particularly powerful pump and Pt100 connection are preferably used for precise temperature control of large-volume external applications. They can be integrated into process control systems via the permanently integrated analog connection.
| Model | Add to compare FCW2500T |
Add to compare FC1200T |
Add to compare FC1600T |
|---|---|---|---|
| Working temperature range (°C) | -25 ... 80 | -10 ... 80 | -15 ... 80 |
| Temperature stability (°C) | ±0.2 | ±0.2 | ±0.2 |
| Cooling capacity (kW) | 2.1 | 1.1 | 1.45 |
| Heating capacity (kW) | 1.2 | 1.2 | 1.2 |
| Pump capacity flow rate (l/min) | 28 | 28 | 28 |
| Pump capacity pressure (bar) | 3.5 | 3.5 | 3.5 |