CORIO CP-BC4 Heating circulator
Laboratory circulators with an expanded working temperature range up to +200 °C
CORIO circulators offer professional technology for high demands. With these devices, temperature control is optionally possible in the internal bath or in a connected external application.
Order No. | 9 013 504 |
---|---|
Working temperature range | +20 ... +200 °C |
Temperature stability | ±0.02 °C |
Heating capacity | 1 kW |
Pump capacity flow pressure | 8 ... 27 l/min |
Circulation capacity pressure | 1.5 ... 10.2 psi |
Usable bath opening (W x L / D) |
5.1 x 5.9 / 5.9 in. |
Filling volume | 3 ... 4.5 l |
Dimensions
(W × L × H) |
9.1 x 16.1 x 16.5 in. |
Product Features
- Models for internal and external applications
- Bright, white, easy to read display
- Very quiet
- easy switching between internal and external circulation
- powerful and infinitely adjustable pressure pump
- USB connection
- RS232 interface for online communication
- High-quality bath tanks made of stainless steel with bath lid and drain tap
- Integrated pump connection M16×1
- Integrated cooling coil for counter-cooling
- Easy operation
Technical data for CORIO CP-BC4
Dimensions (W × L × H) |
9.1 x 16.1 x 16.5 in. |
---|---|
Filling volume | 3 ... 4.5 l |
Weight | 18.7 lbs |
Pump connections | M16x1 male |
Barbed fittings inner diameter | 8/12 mm |
Working temperature range | +20 ... +200 °C |
---|---|
Temperature stability | ±0.02 °C |
Setting the resolution of the temperature display | 0.1 °C |
Temperature display resolution | 0.01 ... 0.1 °C |
Ambient temperature 1 | +5 ... +40 °C |
1 For applications near or below ambient temperature: use a cooling coil or JULABO immersion cooler. |
Heating capacity | 1 kW |
---|---|
Pump capacity flow pressure | 8 ... 27 l/min |
Circulation capacity pressure | 1.5 ... 10.2 psi |
Viscosity max. | 50 cSt |
Power consumption | 10 A |
Bath tank | Stainless steel |
---|---|
Bath cover | integrated |
Usable bath opening (W x L / D) |
5.1 x 5.9 / 5.9 in. |
Classification according to DIN12876-1 |
Classification III (FL) |
---|---|
Pump function | Pressure Pump |
Pump type | Immersion Pump |
Interfaces | RS232 / USB |
---|---|
Temperature control | PID1 |
Absolute temperature calibration | 3 Point Calibration |
Temperature display | LED |
Temperature setting | Keypad |
Electronic Timer h:min |
0 ... 999 |
9013504.33 | 200-230V/50-60Hz (Schuko Plug - CEE 7/4 Plug Type F) |
---|---|
9013504.33.chn | 200-230V/50-60Hz (CN Plug) |
9013504.04 | 200-230V/50-60Hz (UK Plug Type BS1363A) |
9013504.05 | 200-230V/50-60Hz (CH Plug Type SEV 1011) |
9013504.22 | 100-115V/50-60Hz (Nema N5-15 Plug) |
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male) |
Accessory for CORIO CP-BC4
Downloads for CORIO CP-BC4
We would also be happy to send you our printed catalogs and brochures by post.
Request brochureCORIO CP-BC4 Benefits
Brilliant.
Very bright display makes it easy to read even from a distance.
Switch on. And off you go.
Intelligent operating concept. Ready for operation with just a few quick and easy steps.
Timer. Integrated.
CORIO circulators include an integrated timer function. When the set time has elapsed, a signal sounds and the device switches off. Setting range: 0 ... 999 minutes.
Everything at the front.
All operating controls and safety functions are accessed easily and comfortably from the front.
Related Products
Products with similar properties