FL300 Recirculating Coolers for installation below a lab bench
compact models with up to 1.7 kW of cooling capacity for installation below a lab bench
The compact FL models are suited for a wide variety of cooling tasks. Installation under a lab bench saves valuable space. 2 variants: Air-cooled (FL) and water-cooled (FLW).
Order No. | 9660003.02 | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -20 ... +40 °C | |||||||||||||||||||||
Temperature stability | ±0.5 °C | |||||||||||||||||||||
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
||||||||||||||||||||||
Pump capacity flow pressure | 15 l/min | |||||||||||||||||||||
Circulation capacity pressure | 5.1 psi | |||||||||||||||||||||
Filling volume | 3 ... 4.5 l | |||||||||||||||||||||
Dimensions
(W × L × H) |
9.8 x 19.7 x 23.6 in. |
Product Features
- Ergonomic design and easy operation
- Splash-proof keypad
- Large, bright LED display
- Reliable Microprocessor PID temperature control
- Powerful immersion pumps, suitable for continuous operation
- Permissible temperature in return line +80°C
- Easy filling and Drain tap easily accessible
- Low liquid level protection with optical and audible alarm signal
- Integrated stainless steel bath tanks
- Front drain
- No side vents, instruments can be placed right next to other equipment
- RS232 interface for PC connection
- IP class according to IEC 60529: 21
- Alarm output, potential-free change-over contact (max. 30 VA)
Technical data for FL300
Dimensions (W × L × H) |
9.8 x 19.7 x 23.6 in. |
---|---|
Filling volume | 3 ... 4.5 l |
Weight | 77.2 lbs |
Pump connections | M16x1 male |
Barbed fittings inner diameter | 8/12 mm |
Working temperature range | -20 ... +40 °C |
---|---|
Temperature stability | ±0.5 °C |
Setting the resolution of the temperature display | 0.1 °C |
Temperature display resolution | 0.1 °C |
Ambient temperature | +5 ... +40 °C |
Return flow temperature max. | 80 °C |
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
||||||||||||||||||||||
Pump capacity flow pressure | 15 l/min | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Circulation capacity pressure | 5.1 psi | |||||||||||||||||||||
Power consumption | 6 A |
Bath tank | Stainless steel |
---|
Cooling of compressor | 1-stage Air |
---|
Sound pressure level | 55 dbA |
---|---|
Classification according to DIN12876-1 |
Classification I (NFL) |
IP Code according to IEC 60529 |
IP 21 |
Pump type | Centrifugal Pump |
Interfaces | RS232 |
---|---|
Temperature control | PID1 |
Temperature display | LED |
Temperature setting | Keypad |
9660003.01 | 100V/50-60Hz (Nema N5-15 Plug) (R134a) |
---|---|
9660003.13 | 230V/60Hz (Schuko Plug - CEE 7/4 Plug Type F) (R134a) |
9660003.02 | 115V/60Hz (Nema N5-15 Plug) (R134a) |
9660003.03 | 230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F) (R134a) |
9660003.04 | 230V/50Hz (UK Plug Type BS1363A) (R134a) |
9660003.05 | 230V/50Hz (CH Plug Type SEV 1011) (R134a) |
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male) |
Accessory for FL300
Downloads for FL300
We would also be happy to send you our printed catalogs and brochures by post.
Request brochureFL300 Benefits
100% Checked.
100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.
Green technology.
Development consistently applied environmentally friendly materials and technologies.
JULABO. Quality.
Highest standards of quality for a long product life.
Quick start.
Individual JULABO consultation and comprehensive manuals at your disposal.
Related Products
Products with similar properties