Data at mains voltage / frequency:
230V/3PPE/60Hz (Without Plug)
FPW91-SL
Order No. 9 352 793N.07
Working temperature range -91 ... +100 °C
Temperature stability ±0.2 °C
Heating capacity 3 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -20 -40 -60 -80
4.5 4.1 3.7 3.1 2 0.75
Cooling capacity
(Medium: Ethanol)
°C 20 0 -20 -40 -60 -80
kW 4.5 4.1 3.7 3.1 2 0.75
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 5.8 ... 10.2 psi
Filling volume 22 l
Dimensions
(W × L × H)
33.5 x 29.9 x 45.7 in.
FPW91-SL
Order No. 9 352 793N.16
Working temperature range -91 ... +100 °C
Temperature stability ±0.2 °C
Heating capacity 3 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -20 -40 -60 -80
4.5 4.1 3.7 3.1 2 0.75
Cooling capacity
(Medium: Ethanol)
°C 20 0 -20 -40 -60 -80
kW 4.5 4.1 3.7 3.1 2 0.75
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 5.8 ... 10.2 psi
Filling volume 22 l
Dimensions
(W × L × H)
33.5 x 29.9 x 45.7 in.

Product Features

  • VFD COMFORT DISPLAY
  • Keypad for setpoints, warning/safety values and menu functions
  • ICC (Intelligent Cascade Control), self-optimizing temperature control
  • TCF Temperature Control Features to optimize the control behavior
  • ATC3 3-Point-Calibration
  • Pt100 External sensor connection for measurement and control
  • SMART PUMP, electronically adjustable pump stages
  • Adjustable high temperature cut-out, visible via display
  • RS232/RS485 interface for online communication
  • Integrated programmer for 6 x 60 program steps
  • Connections for solenoid valve and HSP booster pump
  • Proportional cooling control
Dimensions and volumes
Dimensions
(W × L × H)
33.5 x 29.9 x 45.7 in.
Filling volume 22 l
Weight 668 lbs
Pump connections M16x1 male
Pump connections M16x1  male
Cooling Water Connection G¾ in.
Temperature values
Working temperature range -91 ... +100 °C
Temperature stability ±0.2 °C
Setting the resolution of the temperature display 0.01 °C
Temperature display resolution 0.01 °C
Ambient temperature +5.0 ... +40.0 °C
Data at mains voltage / frequency:
230V/3PPE/60Hz (Without Plug)
Performance values
Heating capacity 3 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -20 -40 -60 -80
4.5 4.1 3.7 3.1 2 0.75
Cooling capacity
(Medium: Ethanol)
°C 20 0 -20 -40 -60 -80
kW 4.5 4.1 3.7 3.1 2 0.75
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 5.8 ... 10.2 psi
Maximum suction 2.9 ... 5.8 psi
Viscosity max. 70 cST
Refrigerant stage 1
Refrigerant R404A
Global Warming Potential for R404A 3922
Filling volume 900 g
Carbon dioxide equivalent 3.53 t
Refrigerant stage 2
Refrigerant R23
Global Warming Potential for R23 14800
Filling volume 1000 g
Carbon dioxide equivalent 14.8 t
Power 32 A
Performance values
Heating capacity 3 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -20 -40 -60 -80
4.5 4.1 3.7 3.1 2 0.75
Cooling capacity
(Medium: Ethanol)
°C 20 0 -20 -40 -60 -80
kW 4.5 4.1 3.7 3.1 2 0.75
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 5.8 ... 10.2 psi
Maximum suction 2.9 ... 5.8 psi
Viscosity max. 70 cST
Refrigerant stage 1
Refrigerant R404A
Global Warming Potential for R404A 3922
Filling volume 900 g
Carbon dioxide equivalent 3.53 t
Refrigerant stage 2
Refrigerant R23
Global Warming Potential for R23 14800
Filling volume 1000 g
Carbon dioxide equivalent 14.8 t
Power 32 A
Bath
Bath cover integrated
Cooling
Cooling of compressor 2-stage Water
Cooling water pressure max. 87 psi
Cooling water difference pressure 50.8 ... 87 psi
Cooling water temperature max. 20 °C
1.0Cooling water consumption 7.5 l/min
Other
Classification
according to DIN12876-1
Classification III (FL)
IP Code
according to IEC 60529
IP 21
Electronics
Digital interface Profibus optional
External pt100 sensor connection integrated
Integrated programmer 6x60 steps
Temperature control ICC
Absolute temperature calibration 3 Point Calibration
Temperature displayTemperature display VFD
Temperature settingTemperature setting Keypad
Available voltage versions
400V/3PNPE/50Hz Plug 63A CEE 9352793N.07
230V/3PPE/60Hz Without Plug 9352793N.16
Included in delivery
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male)
2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 female).

Accessory for FPW91-SL

We would also be happy to send you our printed catalogs and brochures by post.


Request brochure

Benefits

  • 100% geprüft
    100% Checked.
    100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.
  • Blatt wächst in einer Glühbirne
    Green technology.
    Development consistently applied environmentally friendly materials and technologies.
  • Made in Germany
    JULABO. Quality.
    Highest standards of quality for a long product life.
  • Quickstart
    Quick start.
    Individual JULABO consultation and comprehensive manuals at your disposal.