FP52-SL Ultra-Low Refrigerated / Heating Circulator

low temperatures below -50 °C for internal and external applications

The Ultra-Low Refrigerated Circulators of the HighTech Series with HL or SL circulator feature powerful pressure and suction pumps. The instruments provide the entire variety of functions of the professional HighTech Series of circulators.

Request a quote
Data at mains voltage / frequency:
208V/3PPE/60Hz (Without Plug)
FP52-SL
Order No. 9 352 752
Working temperature range -60 ... +100 °C
Temperature stability ±0.05 °C
Heating capacity 3 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -20 -40 -60
3 2.8 1.6 0.65 0.1
Cooling capacity
(Medium: Ethanol)
°C 20 0 -20 -40 -60
kW 3 2.8 1.6 0.65 0.1
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 5.8 ... 10.2 psi
Usable bath opening
(W x L / D)
11 x 9.1 / 8.7 in.
Filling volume 24 l
Dimensions
(W × L × H)
23.2 x 29.9 x 45.7 in.
FP52-SL
Order No. 9 352 752
Working temperature range -60 ... +100 °C
Temperature stability ±0.05 °C
Heating capacity 3 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -20 -40 -60
3 2.8 1.6 0.65 0.1
Cooling capacity
(Medium: Ethanol)
°C 20 0 -20 -40 -60
kW 3 2.8 1.6 0.65 0.1
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 5.8 ... 10.2 psi
Usable bath opening
(W x L / D)
11 x 9.1 / 8.7 in.
Filling volume 24 l
Dimensions
(W × L × H)
23.2 x 29.9 x 45.7 in.

Product Features

  • VFD COMFORT DISPLAY
  • LCD DIALOG DISPLAY backlit for convenient interactive operation
  • ICC (Intelligent Cascade Control), self-optimizing temperature control
  • TCF Temperature Control Features to optimize the control behavior
  • ATC3 3-Point-Calibration
  • SMART PUMP, electronically adjustable pump stages
  • Adjustable high temperature cut-out, visible via display
  • RS232/RS485 interface for online communication
  • Integrated programmer for 6 x 60 program steps
  • Connections for solenoid valve and HSP booster pump
  • Proportional cooling control
Dimensions and volumes
Dimensions
(W × L × H)
23.2 x 29.9 x 45.7 in.
Filling volume 24 l
Weight 343.9 lbs
Pump connections M16x1 male
Temperature values
Working temperature range -60 ... +100 °C
Temperature stability ±0.05 °C
Setting the resolution of the temperature display 0.01 °C
Temperature display resolution 0.01 °C
Ambient temperature +5.0 ... +40.0 °C
Data at mains voltage / frequency:
208V/3PPE/60Hz (Without Plug)
Performance values
Heating capacity 3 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -20 -40 -60
3 2.8 1.6 0.65 0.1
Cooling capacity
(Medium: Ethanol)
°C 20 0 -20 -40 -60
kW 3 2.8 1.6 0.65 0.1
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 5.8 ... 10.2 psi
Maximum suction 2.9 ... 5.8 psi
Viscosity max. 70 cST
Refrigerant stage 1
Refrigerant R452A
Global Warming Potential for R452A 2140
Filling volume 1000 g
Carbon dioxide equivalent 2.14 t
Power 21 A
Performance values
Heating capacity 3 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -20 -40 -60
3 2.8 1.6 0.65 0.1
Cooling capacity
(Medium: Ethanol)
°C 20 0 -20 -40 -60
kW 3 2.8 1.6 0.65 0.1
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 5.8 ... 10.2 psi
Maximum suction 2.9 ... 5.8 psi
Viscosity max. 70 cST
Refrigerant stage 1
Refrigerant R452A
Global Warming Potential for R452A 2140
Filling volume 1000 g
Carbon dioxide equivalent 2.14 t
Power 25 A
Bath
Bath cover integrated
Usable bath opening
(W x L / D)
11 x 9.1 / 8.7 in.
Cooling
Cooling of compressor Air
Other
Classification
according to DIN12876-1
Classification III (FL)
IP Code
according to IEC 60529
IP 21
Electronics
Digital interface Profibus optional
External pt100 sensor connection integrated
Integrated programmer 6x60 steps
Temperature control ICC
Absolute temperature calibration 3 Point Calibration
Temperature displayTemperature display VFD
Temperature settingTemperature setting Keypad
Available voltage versions
400V/3PNPE/50Hz Plug 32A CEE 9352752.07
208V/3PPE/60Hz Without Plug 9352752.16
Included in delivery
2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 female).
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male)

Accessory for FP52-SL

We would also be happy to send you our printed catalogs and brochures by post.


Request brochure

Benefits

  • 100% geprüft
    100% Checked.
    100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.
  • Blatt wächst in einer Glühbirne
    Green technology.
    Development consistently applied environmentally friendly materials and technologies.
  • Made in Germany
    JULABO. Quality.
    Highest standards of quality for a long product life.
  • Quickstart
    Quick start.
    Individual JULABO consultation and comprehensive manuals at your disposal.