FP51-SL Ultra-Low Refrigerated / Heating Circulator

low temperatures below -50 °C for internal and external applications

The Ultra-Low Refrigerated Circulators of the HighTech Series with HL or SL circulator feature powerful pressure and suction pumps. The instruments provide the entire variety of functions of the professional HighTech Series of circulators.

Request a quote
Data at mains voltage / frequency:
208V/3PPE/60Hz (Without Plug)
FP51-SL
Order No. 9 352 751.06
Working temperature range -51 ... +200 °C
Temperature stability ±0.05 °C
Heating capacity 3 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -20 -40
2 1.5 1 0.26
Cooling capacity
(Medium: Ethanol)
°C 20 0 -20 -40
kW 2 1.5 1 0.26
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 5.8 ... 10.2 psi
Usable bath opening
(W x L / D)
7.1 x 4.7 / 7.9 in.
Filling volume 7.5 ... 12 l
Dimensions
(W × L × H)
18.1 x 21.7 x 35 in.
FP51-SL
Order No. 9 352 751.07
Working temperature range -51 ... +200 °C
Temperature stability ±0.05 °C
Heating capacity 3 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -20 -40
2 1.5 1 0.26
Cooling capacity
(Medium: Ethanol)
°C 20 0 -20 -40
kW 2 1.5 1 0.26
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 5.8 ... 10.2 psi
Usable bath opening
(W x L / D)
7.1 x 4.7 / 7.9 in.
Filling volume 7.5 ... 12 l
Dimensions
(W × L × H)
18.1 x 21.7 x 35 in.
FP51-SL
Order No. 9 352 751.16
Working temperature range -51 ... +200 °C
Temperature stability ±0.05 °C
Heating capacity 3 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -20 -40
2 1.5 1 0.26
Cooling capacity
(Medium: Ethanol)
°C 20 0 -20 -40
kW 2 1.5 1 0.26
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 5.8 ... 10.2 psi
Usable bath opening
(W x L / D)
7.1 x 4.7 / 7.9 in.
Filling volume 7.5 ... 12 l
Dimensions
(W × L × H)
18.1 x 21.7 x 35 in.

Product Features

  • VFD COMFORT DISPLAY
  • ICC (Intelligent Cascade Control), self-optimizing temperature control
  • TCF Temperature Control Features to optimize the control behavior
  • ATC3 3-Point-Calibration
  • SMART PUMP, electronically adjustable pump stages
  • Adjustable high temperature cut-out, visible via display
  • RS232/RS485 interface for online communication
  • Integrated programmer for 6 x 60 program steps
  • Connections for solenoid valve and HSP booster pump
  • Proportional cooling control
Dimensions and volumes
Dimensions
(W × L × H)
18.1 x 21.7 x 35 in.
Filling volume 7.5 ... 12 l
Weight 198.4 lbs
Pump connections M16x1 male
Pump connections M16x1  male
Temperature values
Working temperature range -51 ... +200 °C
Temperature stability ±0.05 °C
Setting the resolution of the temperature display 0.01 °C
Temperature display resolution 0.01 °C
Ambient temperature +5.0 ... +40.0 °C
Data at mains voltage / frequency:
208V/3PPE/60Hz (Without Plug)
Performance values
Heating capacity 3 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -20 -40
2 1.5 1 0.26
Cooling capacity
(Medium: Ethanol)
°C 20 0 -20 -40
kW 2 1.5 1 0.26
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 5.8 ... 10.2 psi
Maximum suction 2.9 ... 5.8 psi
Viscosity max. 70 cST
Refrigerant stage 1
Refrigerant R507
Global Warming Potential for R507 3985
Filling volume 1030 g
Carbon dioxide equivalent 4.105 t
Performance values
Heating capacity 3 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -20 -40
2 1.5 1 0.26
Cooling capacity
(Medium: Ethanol)
°C 20 0 -20 -40
kW 2 1.5 1 0.26
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 5.8 ... 10.2 psi
Maximum suction 2.9 ... 5.8 psi
Viscosity max. 70 cST
Refrigerant stage 1
Refrigerant R507
Global Warming Potential for R507 3985
Filling volume 1030 g
Carbon dioxide equivalent 4.105 t
Performance values
Heating capacity 3 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -20 -40
2 1.5 1 0.26
Cooling capacity
(Medium: Ethanol)
°C 20 0 -20 -40
kW 2 1.5 1 0.26
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 5.8 ... 10.2 psi
Maximum suction 2.9 ... 5.8 psi
Viscosity max. 70 cST
Refrigerant stage 1
Refrigerant R507
Global Warming Potential for R507 3985
Filling volume 1030 g
Carbon dioxide equivalent 4.105 t
Bath
Bath cover integrated
Usable bath opening
(W x L / D)
7.1 x 4.7 / 7.9 in.
Cooling
Cooling of compressor Air
Other
Sound pressure level 63 dbA
Classification
according to DIN12876-1
Classification III (FL)
IP Code
according to IEC 60529
IP 21
Electronics
Digital interface Profibus optional
External pt100 sensor connection integrated
Integrated programmer 6x60 steps
Temperature control ICC
Absolute temperature calibration 3 Point Calibration
Temperature displayTemperature display VFD
Temperature settingTemperature setting Keypad
Available voltage versions
230V/3PPE/50Hz Without Plug 9352751.06
400V/3PNPE/50Hz Plug 16A CEE 9352751.07
208V/3PPE/60Hz Without Plug 9352751.16
Included in delivery
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male)

Accessory for FP51-SL

We would also be happy to send you our printed catalogs and brochures by post.


Request brochure

Benefits

  • 100% geprüft
    100% Checked.
    100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.
  • Blatt wächst in einer Glühbirne
    Green technology.
    Development consistently applied environmentally friendly materials and technologies.
  • ICC
    Intelligent temperature control.
    Intelligent cascade control - automatic and self-optimizing adaptation of the PID control parameters with external stability of +/- 0.05 °C.
  • Made in Germany
    JULABO. Quality.
    Highest standards of quality for a long product life.