F25-HE Refrigerated / Heating Circulator
for working temperatures to +200°C
The HighTech Series features refrigerated heating /circulators with innovative technology for sophisticated applications. The instruments provide powerful, electronically adjustable pressure and suction pumps.
The instruments can be used for internal as well as external temperature control applications of closed and open systems.
Request a quoteOrder No. | 9 212 625 | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -28 ... +200 °C | |||||||||
Temperature stability | ±0.01 °C | |||||||||
Heating capacity | 0.8 kW | |||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||
|
||||||||||
Pump capacity flow rate | 22 ... 26 l/min | |||||||||
Pump capacity flow pressure | 5.8 ... 10.2 psi | |||||||||
Usable bath opening (W x L / D) |
4.7 x 5.5 / 5.5 in. | |||||||||
Filling volume | 3 ... 4.5 l | |||||||||
Dimensions (W × L × H) |
9.1 x 16.5 x 25.2 in. |
Order No. | 9 212 625 | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -28 ... +200 °C | |||||||||
Temperature stability | ±0.01 °C | |||||||||
Heating capacity | 0.8 kW | |||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||
|
||||||||||
Pump capacity flow rate | 22 ... 26 l/min | |||||||||
Pump capacity flow pressure | 5.8 ... 10.2 psi | |||||||||
Usable bath opening (W x L / D) |
4.7 x 5.5 / 5.5 in. | |||||||||
Filling volume | 3 ... 4.5 l | |||||||||
Dimensions (W × L × H) |
9.1 x 16.5 x 25.2 in. |
Order No. | 9 212 625 | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -28 ... +200 °C | |||||||||
Temperature stability | ±0.01 °C | |||||||||
Heating capacity | 1 kW | |||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||
|
||||||||||
Pump capacity flow rate | 22 ... 26 l/min | |||||||||
Pump capacity flow pressure | 5.8 ... 10.2 psi | |||||||||
Usable bath opening (W x L / D) |
4.7 x 5.5 / 5.5 in. | |||||||||
Filling volume | 3 ... 4.5 l | |||||||||
Dimensions (W × L × H) |
9.1 x 16.5 x 25.2 in. |
Order No. | 9 212 625 | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -28 ... +200 °C | |||||||||
Temperature stability | ±0.01 °C | |||||||||
Heating capacity | 2 kW | |||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||
|
||||||||||
Pump capacity flow rate | 22 ... 26 l/min | |||||||||
Pump capacity flow pressure | 5.8 ... 10.2 psi | |||||||||
Usable bath opening (W x L / D) |
4.7 x 5.5 / 5.5 in. | |||||||||
Filling volume | 3 ... 4.5 l | |||||||||
Dimensions (W × L × H) |
9.1 x 16.5 x 25.2 in. |
Order No. | 9 212 625 | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -28 ... +200 °C | |||||||||
Temperature stability | ±0.01 °C | |||||||||
Heating capacity | 2 kW | |||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||
|
||||||||||
Pump capacity flow rate | 22 ... 26 l/min | |||||||||
Pump capacity flow pressure | 5.8 ... 10.2 psi | |||||||||
Usable bath opening (W x L / D) |
4.7 x 5.5 / 5.5 in. | |||||||||
Filling volume | 3 ... 4.5 l | |||||||||
Dimensions (W × L × H) |
9.1 x 16.5 x 25.2 in. |
Order No. | 9 212 625 | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -28 ... +200 °C | |||||||||
Temperature stability | ±0.01 °C | |||||||||
Heating capacity | 2 kW | |||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||
|
||||||||||
Pump capacity flow rate | 22 ... 26 l/min | |||||||||
Pump capacity flow pressure | 5.8 ... 10.2 psi | |||||||||
Usable bath opening (W x L / D) |
4.7 x 5.5 / 5.5 in. | |||||||||
Filling volume | 3 ... 4.5 l | |||||||||
Dimensions (W × L × H) |
9.1 x 16.5 x 25.2 in. |
Order No. | 9 212 625 | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -28 ... +200 °C | |||||||||
Temperature stability | ±0.01 °C | |||||||||
Heating capacity | 2 kW | |||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||
|
||||||||||
Pump capacity flow rate | 22 ... 26 l/min | |||||||||
Pump capacity flow pressure | 5.8 ... 10.2 psi | |||||||||
Usable bath opening (W x L / D) |
4.7 x 5.5 / 5.5 in. | |||||||||
Filling volume | 3 ... 4.5 l | |||||||||
Dimensions (W × L × H) |
9.1 x 16.5 x 25.2 in. |
Order No. | 9 212 625 | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -28 ... +200 °C | |||||||||
Temperature stability | ±0.01 °C | |||||||||
Heating capacity | 2 kW | |||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||
|
||||||||||
Pump capacity flow rate | 22 ... 26 l/min | |||||||||
Pump capacity flow pressure | 5.8 ... 10.2 psi | |||||||||
Usable bath opening (W x L / D) |
4.7 x 5.5 / 5.5 in. | |||||||||
Filling volume | 3 ... 4.5 l | |||||||||
Dimensions (W × L × H) |
9.1 x 16.5 x 25.2 in. |
Product Features
- VFD COMFORT DISPLAY
- Keypad for setpoints, warning/safety values and menu functions
- ICC (Intelligent Cascade Control), self-optimizing temperature control
- ATC3 3-Point-Calibration
- Pt100 External sensor connection for measurement and control
- SMART PUMP, electronically adjustable pump stages
- Adjustable pressure and suction pump
- Adjustable high temperature cut-out, visible via display
- RS232 interface for online communication
- Optional: analogue interfaces
- Integrated programmer for 10 program steps
- Active Cooling Control
Dimensions (W × L × H) |
9.1 x 16.5 x 25.2 in. |
---|---|
Filling volume | 3 ... 4.5 l |
Weight | 70.5 lbs |
Pump connections | M16x1 male |
Barbed fittings inner diameter | 8/12 mm |
Working temperature range | -28 ... +200 °C |
---|---|
Temperature stability | ±0.01 °C |
Temperature stability external | ±0.01 ... ±0.2 °C |
Setting the resolution of the temperature display | 0.01 °C |
Temperature display resolution | 0.01 °C |
Ambient temperature | +5.0 ... +40.0 °C |
Heating capacity | 0.8 kW | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||
|
|||||||||||
Pump capacity flow rate | 22 ... 26 l/min | ||||||||||
Pump capacity flow pressure | 5.8 ... 10.2 psi | ||||||||||
Maximum suction | 2.9 ... 5.8 psi | ||||||||||
Viscosity max. | 70 cST | ||||||||||
Refrigerant stage 1 |
Refrigerant | R134a | |||||||||
Global Warming Potential for R134a | 1430 | ||||||||||
Filling volume | 84 g | ||||||||||
Carbon dioxide equivalent | 0.12 t | ||||||||||
Power | 13 A |
Heating capacity | 0.8 kW | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||
|
|||||||||||
Pump capacity flow rate | 22 ... 26 l/min | ||||||||||
Pump capacity flow pressure | 5.8 ... 10.2 psi | ||||||||||
Maximum suction | 2.9 ... 5.8 psi | ||||||||||
Viscosity max. | 70 cST | ||||||||||
Refrigerant stage 1 |
Refrigerant | R134a | |||||||||
Global Warming Potential for R134a | 1430 | ||||||||||
Filling volume | 84 g | ||||||||||
Carbon dioxide equivalent | 0.12 t | ||||||||||
Power | 13 A |
Heating capacity | 1 kW | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||
|
|||||||||||
Pump capacity flow rate | 22 ... 26 l/min | ||||||||||
Pump capacity flow pressure | 5.8 ... 10.2 psi | ||||||||||
Maximum suction | 2.9 ... 5.8 psi | ||||||||||
Viscosity max. | 70 cST | ||||||||||
Refrigerant stage 1 |
Refrigerant | R134a | |||||||||
Global Warming Potential for R134a | 1430 | ||||||||||
Filling volume | 84 g | ||||||||||
Carbon dioxide equivalent | 0.12 t | ||||||||||
Power | 13 A |
Heating capacity | 2 kW | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||
|
|||||||||||
Pump capacity flow rate | 22 ... 26 l/min | ||||||||||
Pump capacity flow pressure | 5.8 ... 10.2 psi | ||||||||||
Maximum suction | 2.9 ... 5.8 psi | ||||||||||
Viscosity max. | 70 cST | ||||||||||
Refrigerant stage 1 |
Refrigerant | R134a | |||||||||
Global Warming Potential for R134a | 1430 | ||||||||||
Filling volume | 84 g | ||||||||||
Carbon dioxide equivalent | 0.12 t | ||||||||||
Power | 12 A |
Heating capacity | 2 kW | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||
|
|||||||||||
Pump capacity flow rate | 22 ... 26 l/min | ||||||||||
Pump capacity flow pressure | 5.8 ... 10.2 psi | ||||||||||
Maximum suction | 2.9 ... 5.8 psi | ||||||||||
Viscosity max. | 70 cST | ||||||||||
Refrigerant stage 1 |
Refrigerant | R134a | |||||||||
Global Warming Potential for R134a | 1430 | ||||||||||
Filling volume | 84 g | ||||||||||
Carbon dioxide equivalent | 0.12 t | ||||||||||
Power | 12 A |
Heating capacity | 2 kW | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||
|
|||||||||||
Pump capacity flow rate | 22 ... 26 l/min | ||||||||||
Pump capacity flow pressure | 5.8 ... 10.2 psi | ||||||||||
Maximum suction | 2.9 ... 5.8 psi | ||||||||||
Viscosity max. | 70 cST | ||||||||||
Refrigerant stage 1 |
Refrigerant | R134a | |||||||||
Global Warming Potential for R134a | 1430 | ||||||||||
Filling volume | 84 g | ||||||||||
Carbon dioxide equivalent | 0.12 t | ||||||||||
Power | 12 A |
Heating capacity | 2 kW | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||
|
|||||||||||
Pump capacity flow rate | 22 ... 26 l/min | ||||||||||
Pump capacity flow pressure | 5.8 ... 10.2 psi | ||||||||||
Maximum suction | 2.9 ... 5.8 psi | ||||||||||
Viscosity max. | 70 cST | ||||||||||
Refrigerant stage 1 |
Refrigerant | R134a | |||||||||
Global Warming Potential for R134a | 1430 | ||||||||||
Filling volume | 84 g | ||||||||||
Carbon dioxide equivalent | 0.12 t | ||||||||||
Power | 2 A |
Heating capacity | 2 kW | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||
|
|||||||||||
Pump capacity flow rate | 22 ... 26 l/min | ||||||||||
Pump capacity flow pressure | 5.8 ... 10.2 psi | ||||||||||
Maximum suction | 2.9 ... 5.8 psi | ||||||||||
Viscosity max. | 70 cST | ||||||||||
Refrigerant stage 1 |
Refrigerant | R134a | |||||||||
Global Warming Potential for R134a | 1430 | ||||||||||
Filling volume | 84 g | ||||||||||
Carbon dioxide equivalent | 0.12 t | ||||||||||
Power | 12 A |
Bath cover | integrated |
---|---|
Usable bath opening (W x L / D) |
4.7 x 5.5 / 5.5 in. |
Cooling of compressor | 1-stage Air |
---|
Sound pressure level | 49 dbA |
---|---|
Classification according to DIN12876-1 |
Classification III (FL) |
IP Code according to IEC 60529 |
IP 21 |
Pump type | Immersion Pump |
Digital interface | Profibus optional |
---|---|
External pt100 sensor connection | integrated |
Integrated programmer | 1x10 steps |
Temperature control | ICC |
Absolute temperature calibration | 3 Point Calibration |
Temperature displayTemperature display | VFD |
Temperature settingTemperature setting | Keypad |
100V/50-60Hz Nema N5-15 Plug | 9212625.01 |
---|---|
115V/60Hz Nema N5-15 Plug | 9212625.02 |
230V/50-60Hz Schuko Plug - CEE 7/4 Plug Type F | 9212625.33 |
230V/50Hz Schuko Plug - CEE 7/4 Plug Type F | 9212625.03 |
230V/50-60Hz CH Plug Type SEV 1011 | 9212625.05 |
230V/50Hz UK Plug Type BS1363A | 9212625.04 |
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male) |
Accessory for F25-HE
Benefits
-
100% Checked.
100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory. -
Green technology.
Development consistently applied environmentally friendly materials and technologies. -
JULABO. Quality.
Highest standards of quality for a long product life. -
Quick start.
Individual JULABO consultation and comprehensive manuals at your disposal.