CORIO CD-1001F Refrigerated / Heating Circulator
The new generation of laboratory circulators for routine work and standard tasks
Refrigerated / Heating Circulators of the new CORIO series distinguish themselves with a great price-to-performance ratio. They are ideal for all standard tasks and routine work in laboratories and industry.
Request a quoteOrder No. | 9 012 708.03 | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +100 °C | |||||||||||||||
Temperature stability | ±0.03 °C | |||||||||||||||
Heating capacity | 2 kW | |||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||
|
||||||||||||||||
Pump capacity flow rate | 15 l/min | |||||||||||||||
Pump capacity flow pressure | 5.1 psi | |||||||||||||||
Usable bath opening (W x L / D) |
13.8 x 16.1 / 11.8 in. | |||||||||||||||
Filling volume | 42 ... 56 l | |||||||||||||||
Dimensions (W × L × H) |
17.7 x 25.2 x 37.4 in. |
Order No. | 9 012 708.03.chn | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +100 °C | |||||||||||||||
Temperature stability | ±0.03 °C | |||||||||||||||
Heating capacity | 2 kW | |||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||
|
||||||||||||||||
Pump capacity flow rate | 15 l/min | |||||||||||||||
Pump capacity flow pressure | 5.1 psi | |||||||||||||||
Usable bath opening (W x L / D) |
13.8 x 16.1 / 11.8 in. | |||||||||||||||
Filling volume | 42 ... 56 l | |||||||||||||||
Dimensions (W × L × H) |
17.7 x 25.2 x 37.4 in. |
Order No. | 9 012 708.04 | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +100 °C | |||||||||||||||
Temperature stability | ±0.03 °C | |||||||||||||||
Heating capacity | 2 kW | |||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||
|
||||||||||||||||
Pump capacity flow rate | 15 l/min | |||||||||||||||
Pump capacity flow pressure | 5.1 psi | |||||||||||||||
Usable bath opening (W x L / D) |
13.8 x 16.1 / 11.8 in. | |||||||||||||||
Filling volume | 42 ... 56 l | |||||||||||||||
Dimensions (W × L × H) |
17.7 x 25.2 x 37.4 in. |
Order No. | 9 012 708.05 | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +100 °C | |||||||||||||||
Temperature stability | ±0.03 °C | |||||||||||||||
Heating capacity | 2 kW | |||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||
|
||||||||||||||||
Pump capacity flow rate | 15 l/min | |||||||||||||||
Pump capacity flow pressure | 5.1 psi | |||||||||||||||
Usable bath opening (W x L / D) |
13.8 x 16.1 / 11.8 in. | |||||||||||||||
Filling volume | 42 ... 56 l | |||||||||||||||
Dimensions (W × L × H) |
17.7 x 25.2 x 37.4 in. |
Order No. | 9 012 708.13 | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +100 °C | |||||||||||||||
Temperature stability | ±0.03 °C | |||||||||||||||
Heating capacity | 2 kW | |||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||
|
||||||||||||||||
Pump capacity flow rate | 17 l/min | |||||||||||||||
Pump capacity flow pressure | 6.2 psi | |||||||||||||||
Usable bath opening (W x L / D) |
13.8 x 16.1 / 11.8 in. | |||||||||||||||
Filling volume | 42 ... 56 l | |||||||||||||||
Dimensions (W × L × H) |
17.7 x 25.2 x 37.4 in. |
Order No. | 9 012 708.12 | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +100 °C | |||||||||||||||
Temperature stability | ±0.03 °C | |||||||||||||||
Heating capacity | 1.5 kW | |||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||
|
||||||||||||||||
Pump capacity flow rate | 12 l/min | |||||||||||||||
Pump capacity flow pressure | 4.4 psi | |||||||||||||||
Usable bath opening (W x L / D) |
13.8 x 16.1 / 11.8 in. | |||||||||||||||
Filling volume | 42 ... 56 l | |||||||||||||||
Dimensions (W × L × H) |
17.7 x 25.2 x 37.4 in. |
Order No. | 9 012 708.12 | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +100 °C | |||||||||||||||
Temperature stability | ±0.03 °C | |||||||||||||||
Heating capacity | 1.5 kW | |||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||
|
||||||||||||||||
Pump capacity flow rate | 14 l/min | |||||||||||||||
Pump capacity flow pressure | 4.8 psi | |||||||||||||||
Usable bath opening (W x L / D) |
13.8 x 16.1 / 11.8 in. | |||||||||||||||
Filling volume | 42 ... 56 l | |||||||||||||||
Dimensions (W × L × H) |
17.7 x 25.2 x 37.4 in. |
Product Features
- Models for internal and external applications
- Bright, white, easy to read display
- Very quiet
- Easy pump change-over between internal and external circulation
- External pump connections
- USB connection
- Space-saving cooling coil design provides more usable space in the bath tank
- Bath lid and drain tap included
- Removable ventilation grid
- Refrigeration unit without side vents
- Class III (FL) according to DIN 12876-1
- Very quiet
- High-quality bath tanks made of stainless steel with bath lid and drain tap
Dimensions (W × L × H) |
17.7 x 25.2 x 37.4 in. |
---|---|
Filling volume | 42 ... 56 l |
Weight | 163.1 lbs |
Pump connections | M16x1 male |
Pump connections | M16x1 male |
Barbed fittings inner diameter | 8/12 mm |
Working temperature range | -38 ... +100 °C |
---|---|
Temperature stability | ±0.03 °C |
Setting the resolution of the temperature display | 0.1 °C |
Temperature display resolution | 0.01 ... 0.1 °C |
Ambient temperature | +5 ... +40 °C |
Heating capacity | 2 kW | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||
|
|||||||||||||||||
Pump capacity flow rate | 15 l/min | ||||||||||||||||
Pump capacity flow pressure | 5.1 psi | ||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||
Filling volume | 170 g | ||||||||||||||||
Carbon dioxide equivalent | 0.237 t | ||||||||||||||||
Power | 14 A |
Heating capacity | 2 kW | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||
|
|||||||||||||||||
Pump capacity flow rate | 15 l/min | ||||||||||||||||
Pump capacity flow pressure | 5.1 psi | ||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||
Filling volume | 170 g | ||||||||||||||||
Carbon dioxide equivalent | 0.237 t | ||||||||||||||||
Power | 14 A |
Heating capacity | 2 kW | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||
|
|||||||||||||||||
Pump capacity flow rate | 15 l/min | ||||||||||||||||
Pump capacity flow pressure | 5.1 psi | ||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||
Filling volume | 170 g | ||||||||||||||||
Carbon dioxide equivalent | 0.237 t | ||||||||||||||||
Power | 13 A |
Heating capacity | 2 kW | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||
|
|||||||||||||||||
Pump capacity flow rate | 15 l/min | ||||||||||||||||
Pump capacity flow pressure | 5.1 psi | ||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||
Filling volume | 170 g | ||||||||||||||||
Carbon dioxide equivalent | 0.237 t | ||||||||||||||||
Power | 10 A |
Heating capacity | 2 kW | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||
|
|||||||||||||||||
Pump capacity flow rate | 17 l/min | ||||||||||||||||
Pump capacity flow pressure | 6.2 psi | ||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||
Filling volume | 170 g | ||||||||||||||||
Carbon dioxide equivalent | 0.237 t | ||||||||||||||||
Power | 14 A |
Heating capacity | 1.5 kW | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||
|
|||||||||||||||||
Pump capacity flow rate | 12 l/min | ||||||||||||||||
Pump capacity flow pressure | 4.4 psi | ||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||
Filling volume | 170 g | ||||||||||||||||
Carbon dioxide equivalent | 0.237 t | ||||||||||||||||
Power | 11 A |
Heating capacity | 1.5 kW | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||
|
|||||||||||||||||
Pump capacity flow rate | 14 l/min | ||||||||||||||||
Pump capacity flow pressure | 4.8 psi | ||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||
Filling volume | 170 g | ||||||||||||||||
Carbon dioxide equivalent | 0.237 t | ||||||||||||||||
Power | 11 A |
Bath tank | Stainless steel |
---|---|
Bath cover | integrated |
Usable bath opening (W x L / D) |
13.8 x 16.1 / 11.8 in. |
Cooling of compressor | 1-stage Air |
---|
Classification according to DIN12876-1 |
Classification III (FL) |
---|---|
IP Code according to IEC 60529 |
IP 21 |
Pump function | Pressure Pump |
Pump type | Immersion Pump |
Temperature control | PID1 |
---|---|
Absolute temperature calibration | 1 Point Calibration |
Temperature displayTemperature display | LED |
Temperature settingTemperature setting | Keypad |
230V/50Hz Schuko Plug - CEE 7/4 Plug Type F | 9012708.03 |
---|---|
230V/50Hz CN Plug | 9012708.03.chn |
230V/50Hz UK Plug Type BS1363A | 9012708.04 |
230V/50Hz CH Plug Type SEV 1011 | 9012708.05 |
230V/60Hz Schuko Plug - CEE 7/4 Plug Type F | 9012708.13 |
200V/50-60Hz Nema N6-20 Plug | 9012708.12 |
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male) |
Accessory for CORIO CD-1001F
Benefits
-
100% Checked.
100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory. -
ATC.
Absolute Temperature Calibration, 1-point calibration (CD). -
Handle with ease.
Makes day-to-day work easy. Comfortably move your CORIO around by using the ergonomic handles (front and rear). -
Mobile.
Extra easy handling. Integrated castors for easy repositioning of refrigerated circulators.