SL-14K HighTech SL Calibration Bath

for working temperatures from +50 °C to +200 °C

JULABO calibration baths are ideal for high precision calibration of sensors, measuring instruments, thermometers, etc. The instruments are certified for application in DKD laboratories and according to the requirements specified by DIN EN ISO 9001:2000.

Request a quote
Data at mains voltage / frequency:
230V/60Hz (Schuko Plug - CEE 7/4 Plug Type F)
SL-14K
Order No. 9 352 514
Working temperature range +50 ... +300 °C
Temperature stability ±0.005 °C
Heating capacity 3 kW
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 5.8 ... 10.2 psi
Usable bath opening
(W x L / D)
4.7 x 12.2 / in.
Filling volume 14 l
Dimensions
(W × L × H)
8.7 x 18.1 x 24 in.
SL-14K
Order No. 9 352 514
Working temperature range +50 ... +300 °C
Temperature stability ±0.005 °C
Heating capacity 3 kW
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 5.8 ... 10.2 psi
Usable bath opening
(W x L / D)
4.7 x 12.2 / in.
Filling volume 14 l
Dimensions
(W × L × H)
8.7 x 18.1 x 24 in.
SL-14K
Order No. 9 352 514
Working temperature range +50 ... +300 °C
Temperature stability ±0.005 °C
Heating capacity 3 kW
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 5.8 ... 10.2 psi
Usable bath opening
(W x L / D)
4.7 x 12.2 / in.
Filling volume 14 l
Dimensions
(W × L × H)
8.7 x 18.1 x 24 in.
SL-14K
Order No. 9 352 514
Working temperature range +50 ... +300 °C
Temperature stability ±0.005 °C
Heating capacity 3 kW
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 5.8 ... 10.2 psi
Usable bath opening
(W x L / D)
4.7 x 12.2 / in.
Filling volume 14 l
Dimensions
(W × L × H)
8.7 x 18.1 x 24 in.

Product Features

  • VFD COMFORT DISPLAY
  • LCD DIALOG DISPLAY backlit for convenient interactive operation
  • Keypad for setpoints, warning/safety values and menu functions
  • ICC (Intelligent Cascade Control), self-optimizing temperature control
  • TCF Temperature Control Features to optimize the control behavior
  • ATC3 3-Point-Calibration
  • Pt100 External sensor connection for measurement and control
  • SMART PUMP, electronically adjustable pump stages
  • Adjustable high temperature cut-out, visible via display
  • Integrated programmer for 6 x 60 program steps
  • Highest temperature stability to ±0.005 °C (±0.02 °C at +200 °C)
  • Temperature uniformity better than ±0.01 °C
  • Optional Pt100 sensor for reference temperature measurements
  • Temperature chamber with overflow at maximum liquid level
Dimensions and volumes
Dimensions
(W × L × H)
8.7 x 18.1 x 24 in.
Filling volume 14 l
Usable immersion depth 12.2 in.
Weight 44.1 lbs
Temperature values
Working temperature range +50 ... +300 °C
Temperature stability ±0.005 °C
Temperature display resolution 0.01 °C
Ambient temperature 5 ... 40 °C
Data at mains voltage / frequency:
230V/60Hz (Schuko Plug - CEE 7/4 Plug Type F)
Performance values
Heating capacity 3 kW
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 5.8 ... 10.2 psi
Maximum suction 2.9 ... 5.8 psi
Viscosity max. 70 cST
Power 13 A
Performance values
Heating capacity 3 kW
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 5.8 ... 10.2 psi
Maximum suction 2.9 ... 5.8 psi
Viscosity max. 70 cST
Power 13 A
Performance values
Heating capacity 3 kW
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 5.8 ... 10.2 psi
Maximum suction 2.9 ... 5.8 psi
Viscosity max. 70 cST
Power 14 A
Performance values
Heating capacity 3 kW
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 5.8 ... 10.2 psi
Maximum suction 2.9 ... 5.8 psi
Viscosity max. 70 cST
Power 14 A
Bath
Bath tank Stainless steel
Bath cover integrated
Usable bath opening
(W x L / D)
4.7 x 12.2 / in.
Cooling
Cooling coil integrated
Other
Classification
according to DIN12876-1
Classification III (FL)
IP Code
according to IEC 60529
IP 21
Pump type Immersion Pump
Electronics
Digital interface Profibus optional
External pt100 sensor connection integrated
Integrated programmer 6x60 steps
Temperature control ICC
Absolute temperature calibration 3 Point Calibration
Temperature displayTemperature display VFD
Temperature settingTemperature setting Keypad
Available voltage versions
230V/50-60Hz Schuko Plug - CEE 7/4 Plug Type F 9352514.33
Included in delivery
Including bath cover with 7 openings.

Accessory for SL-14K

We would also be happy to send you our printed catalogs and brochures by post.


Request brochure

Benefits

  • Made in Germany
    JULABO. Quality.
    Highest standards of quality for a long product life.
  • Blatt wächst in einer Glühbirne
    Green technology.
    Development consistently applied environmentally friendly materials and technologies.
  • network
    Satisfied customers.
    11 subsidiaries and more than 100 partners worldwide guarantee fast and qualified JULABO support.
  • 100% geprüft
    100% Checked.
    100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.