SE-Z SE-Z Bridge Mounted Circulator
with extendable bridge for bath tanks up to 100 liters filling volume
JULABO bridge mounted circulator with extendable bridge made of stainless steel for any bath tanks. For internal and external temperature applications. The model offers high pump and heating capacities for temperature control of large baths up to 100 liters. Including a built-in cooling coil for counter-cooling with tap water.
Request a quoteOrder No. | 9 252 218.33 | |
---|---|---|
Working temperature range | +20 ... +300 °C | |
Temperature stability | +/-0.01 °C | |
Heating capacity | 2.5 kW | |
Pump capacity flow rate | 22 ... 26 l/min | |
Pump capacity flow pressure | 5.8 ... 10.2 psi | |
Dimensions (W × L × H) |
12.6 x 6.7 x 16.1 in. |
Order No. | 9 252 218.33 | |
---|---|---|
Working temperature range | +20 ... +300 °C | |
Temperature stability | +/-0.01 °C | |
Heating capacity | 3 kW | |
Pump capacity flow rate | 22 ... 26 l/min | |
Pump capacity flow pressure | 5.8 ... 10.2 psi | |
Dimensions (W × L × H) |
12.6 x 6.7 x 16.1 in. |
Order No. | 9 252 218.33 | |
---|---|---|
Working temperature range | +20 ... +300 °C | |
Temperature stability | +/-0.01 °C | |
Heating capacity | 3 kW | |
Pump capacity flow rate | 22 ... 26 l/min | |
Pump capacity flow pressure | 5.8 ... 10.2 psi | |
Dimensions (W × L × H) |
12.6 x 6.7 x 16.1 in. |
Product Features
- Integrated cooling coil for counter-cooling
- Unique early warning system for low liquid level
- VFD COMFORT DISPLAY
- Keypad for setpoints, warning/safety values and menu functions
- ATC3 3-Point-Calibration
- Pt100 External sensor connection for measurement and control
- SMART PUMP, electronically adjustable pump stages
- Adjustable high temperature cut-out, visible via display
- ICC (Intelligent Cascade Control), self-optimizing temperature control
- Expandable bridge from 31 to 66 cm
Dimensions (W × L × H) |
12.6 x 6.7 x 16.1 in. |
---|---|
Weight | 17.6 lbs |
Pump connections | M16x1 male |
Pump connections | M16x1 male |
Working temperature range | +20 ... +300 °C |
---|---|
Temperature stability | +/-0.01 °C |
Setting the resolution of the temperature display | 0.01 °C |
Temperature display resolution | 0.01 °C |
Ambient temperature | +5 ... +40.0 °C |
Heating capacity | 2.5 kW | ||
---|---|---|---|
Pump capacity flow rate | 22 ... 26 l/min | ||
Pump capacity flow pressure | 5.8 ... 10.2 psi | ||
Maximum suction | 2.9 ... 5.8 psi | ||
Viscosity max. | 50 cST | ||
Power | 13 A |
Heating capacity | 3 kW | ||
---|---|---|---|
Pump capacity flow rate | 22 ... 26 l/min | ||
Pump capacity flow pressure | 5.8 ... 10.2 psi | ||
Maximum suction | 2.9 ... 5.8 psi | ||
Viscosity max. | 50 cST | ||
Power | 14 A |
Heating capacity | 3 kW | ||
---|---|---|---|
Pump capacity flow rate | 22 ... 26 l/min | ||
Pump capacity flow pressure | 5.8 ... 10.2 psi | ||
Maximum suction | 2.9 ... 10.2 psi | ||
Viscosity max. | 50 cST | ||
Power | 14 A |
Cooling coil | integrated |
---|
Classification according to DIN12876-1 |
Classification III (FL) |
---|---|
IP Code according to IEC 60529 |
IP 21 |
External pt100 sensor connection | integrated |
---|---|
Integrated programmer | 6x60 steps |
Temperature control | ICC |
Absolute temperature calibration | 3 Point Calibration |
Temperature displayTemperature display | VFD |
Temperature settingTemperature setting | Keypad |
230V/50-60Hz Schuko Plug - CEE 7/4 Plug Type F | 9252218.33 |
---|
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male) |
Accessory for SE-Z
Benefits
-
JULABO. Quality.
Highest standards of quality for a long product life. -
Green technology.
Development consistently applied environmentally friendly materials and technologies. -
Satisfied customers.
11 subsidiaries and more than 100 partners worldwide guarantee fast and qualified JULABO support. -
100% Checked.
100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.