Breadcrumb

SW23 Shaking Water Bath

2 models with shaking function and up to 20 liters filling volume

JULABO Shaking Water Baths provide numerous state-of-the-art features for common day-to-day laboratory tasks. For example: sloped edges keep water in the stainless steel bath tank even when bath lid is open.

Request a quote
Data at mains voltage / frequency:
230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F)
SW23
Order No. 9 550 323
Working temperature range +20 ... +99.9 °C
Temperature stability ±0.02 °C
Heating capacity 1 kW
Usable bath opening
(W x L / D)
50 x 30 / 18 cm
Filling volume 8 ... 20 l
Dimensions
(W × L × H)
70 x 35 x 26 cm
SW23
Order No. 9 550 323
Working temperature range +20 ... +99.9 °C
Temperature stability ±0.02 °C
Heating capacity 2 kW
Usable bath opening
(W x L / D)
50 x 30 / 18 cm
Filling volume 8 ... 20 l
Dimensions
(W × L × H)
70 x 35 x 26 cm
SW23
Order No. 9 550 323
Working temperature range +20 ... +99.9 °C
Temperature stability ±0.02 °C
Heating capacity 2 kW
Usable bath opening
(W x L / D)
50 x 30 / 18 cm
Filling volume 8 ... 20 l
Dimensions
(W × L × H)
70 x 35 x 26 cm
SW23
Order No. 9 550 323
Working temperature range +20 ... +99.9 °C
Temperature stability ±0.02 °C
Heating capacity 2 kW
Usable bath opening
(W x L / D)
50 x 30 / 18 cm
Filling volume 8 ... 20 l
Dimensions
(W × L × H)
70 x 35 x 26 cm
SW23
Order No. 9 550 323
Working temperature range +20 ... +99.9 °C
Temperature stability ±0.02 °C
Heating capacity 2 kW
Usable bath opening
(W x L / D)
50 x 30 / 18 cm
Filling volume 8 ... 20 l
Dimensions
(W × L × H)
70 x 35 x 26 cm
SW23
Order No. 9 550 323
Working temperature range +20 ... +99.9 °C
Temperature stability ±0.02 °C
Heating capacity 2 kW
Usable bath opening
(W x L / D)
50 x 30 / 18 cm
Filling volume 8 ... 20 l
Dimensions
(W × L × H)
70 x 35 x 26 cm
SW23
Order No. 9 550 323
Working temperature range +20 ... +99.9 °C
Temperature stability ±0.02 °C
Heating capacity 2 kW
Usable bath opening
(W x L / D)
50 x 30 / 18 cm
Filling volume 8 ... 20 l
Dimensions
(W × L × H)
70 x 35 x 26 cm

Product Features

  • Working temperature range from +20 to+99.9 °C
  • User-friendly operation via keypad
  • Bright LED-Display
  • Splash-proof design
  • Power switch integrated in keypad (patented)
  • High temperature stability of ±0.2 °C or ±0.02 °C
  • Dry-running protection with audible and optical alarm
  • Warning and cut-off protection for high/low temperature
  • Adjustable shaking frequencies from 20 to 200 RPM‘s in SW models
  • Convenient bath drains
  • Removable bottom plate and shaking insert
  • Lift-up bath cover (optional)
  • Wide selection of accessories for temperature control of samples
  • All wetted parts are made of stainless steel or high grade plastics
Dimensions and volumes
Dimensions
(W × L × H)
70 x 35 x 26 cm
Filling volume 8 ... 20 l
Usable immersion depth 18 cm
Weight 20.7 kg
Temperature values
Working temperature range +20 ... +99.9 °C
Temperature stability ±0.02 °C
Setting the resolution of the temperature display 0.1 °C
Ambient temperature 5 ... 40 °C
Data at mains voltage / frequency:
230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F)
Performance values
Heating capacity 1 kW
Power 9 A
Performance values
Heating capacity 2 kW
Power 9 A
Performance values
Heating capacity 2 kW
Power 9 A
Performance values
Heating capacity 2 kW
Power 9 A
Performance values
Heating capacity 2 kW
Power 9 A
Performance values
Heating capacity 2 kW
Power 9 A
Performance values
Heating capacity 2 kW
Power 9 A
Bath
Bath tank Stainless steel
Bath cover accessory
Usable bath opening
(W x L / D)
50 x 30 / 18 cm
Waterbath
Dimension with bathcover
(W x L x H)
70 x 35 x 43 cm
Shaking frequency / adjustable Shaking frequency 20 ... 200 rpm
Shaking stroke / adjustable shaking stroke 15 mm
Other
Classification
according to DIN12876-1
Classification I (NFL)
IP Code
according to IEC 60529
IP 21
Electronics
Temperature control PID1
Temperature display LED
Temperature setting Keypad
Available voltage versions
115V/60Hz Nema N5-15 Plug 9550323.02
230V/50-60Hz Schuko Plug - CEE 7/4 Plug Type F 9550323.03
230V/50-60Hz UK Plug Type BS1363A 9550323.04
230V/50-60Hz CH Plug Type SEV 1011 9550323.05

Accessory for SW23

We would also be happy to send you our printed catalogs and brochures by post.


Request brochure

Benefits

  • PID2
    Precise
    PID Temperature control with set control parameters, temperature stability ±0.02...±0.2 °C
  • TCF
    Automatic control of operating time
    Electronic countdown-timer function for timer-programmed unit shut-down, standby mode after programmed time expires
  • Made in Germany
    JULABO. Quality.
    Highest standards of quality for a long product life.
  • Blatt wächst in einer Glühbirne
    Green technology.
    Development consistently applied environmentally friendly materials and technologies.