SL-14K HighTech SL calibration bath

for working temperatures from +50 °C to +300 °C

JULABO calibration baths are ideal for high precision calibration of sensors, measuring instruments, thermometers, etc. The instruments are certified for application in DKD laboratories and according to the requirements specified by DIN EN ISO 9001:2000.

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
SL-14K
Order number including voltage version 9352514.33
Working temperature range +50 ... +300 °C
Temperature stability ±0.005 °C
Heating capacity 3 kW
Pump capacity flow pressure 22 ... 26 l/min
Pump capacity pressure 0.4 ... 0.7 bar
Usable bath opening
(W x L / D)
12 cm
Filling volume 14 l
Total dimensions
(W × L × H)
22 x 46 x 61 cm
Arrange callback

Product Features

  • LCD DIALOG DISPLAY backlit for convenient interactive operation
  • ICC (Intelligent Cascade Control), self-optimizing temperature control
  • TCF Temperature Control Features to optimize the control behavior
  • Integrated programmer for 6 x 60 program steps
  • Highest temperature stability to ±0.005 °C (±0.02 °C at +200 °C)
  • Temperature uniformity better than ±0.01 °C
  • Optional Pt100 sensor for reference temperature measurements
  • Temperature chamber with overflow at maximum liquid level

Technical data for SL-14K

Dimensions and volumes
Total dimensions
(W × L × H)
22 x 46 x 61 cm
Filling volume 14 l
Usable immersion depth 31 cm
Weight 20 kg
Temperature values
Working temperature range +50 ... +300 °C
Temperature stability ±0.005 °C
Temperature display resolution 0.01 °C
Ambient temperature 1 +5 ... +40 °C

1 Depending on the ambient temperature and the bath fluid used, it may be necessary to use the cooling coil for temperature applications around +50 °C.

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Heating capacity 3 kW
Pump capacity flow pressure 22 ... 26 l/min
Pump capacity pressure 0.4 ... 0.7 bar
Maximum suction 0.2 ... 0.4 bar
Viscosity max. 70 cSt
Power consumption 14 A
Bath
Bath tank Stainless steel
Bath cover integrated
Usable bath opening
(W x L / D)
12 cm
Cooling
Cooling coil integrated
Other
Classification
according to DIN12876-1
Classification III (FL)
IP Code
according to IEC 60529
IP 21
Pump type Immersion Pump
Electronics
Interfaces Profibus optional
External pt100 sensor connection integrated
Integrated programmer 6x60 steps
Temperature control ICC
Absolute temperature calibration 3 Point Calibration
Temperature display VFD
Temperature setting Keypad
Available voltage versions
9352514.33 230V/50-60Hz (Schuko Plug - CEE 7/4 Plug Type F)
Included in delivery
Including bath cover with seven openings

Accessory for SL-14K

Downloads for SL-14K

We would also be happy to send you our printed catalogs and brochures by post.

Request brochure

SL-14K Benefits

Connection of additional equipment

Stakei connections for solenoid valve, HSP booster pump and HST booster heater

Early warning system for high/low temperature limits

Maximum safety for applications, optical and audible alarm, convertible to automated cut-off function

Clever pump system

Reliable and consistent pump capacity, electronically adjustable pump stages

Control of the external application

External Pt100 sensor connection for precise measurement and control directly in the external application

Show all 16 benefits

JULABO customer survey

We appreciate if you take part and help us to further improve. The survey takes only 3 minutes and is anonymous. Thank you!