Skip to main content
Logo JULABO USA, Inc.
  • Products
    Products by category
    Refrigerated circulators
    • Refrigerated / Heating Circulators
    • Ultra-Low Refrigerated-Heating Circulators
    Heating Circulators
    • Heating Immersion Circulators
    • Open heating bath circulators
    • Heating Circulators
    • Heating circulators with open bath
    • Bridge mounted circulators
    Highly Dynamic Temperature Control Systems
    • PRESTO process systems
    • Forte HT High Temperature Circulators
    Recirculating Coolers
    • VALEGRO Recirculating Coolers
    • VIGORO recirculating cooler
    • FL Recirculating coolers
    • Recirculating coolers without refrigerant
    Water Baths
    Shaking Water Baths
    Products for Special Applications
    Accessories
    Calibration baths
    Used equipment
    Customized special solutions
    Product filter
    Product brands
    MAGIO MS-Z JULABO MAGIO Brand Logo
    DYNEO DD Immersion Circulator JULABO DYNEO Brand Logo
    CORIO Immersion Circulator CORIO Product Family
    PRESTO W56 JULABO PRESTO Brand Logo
    PURA 14 Watherbath JULABO PURA Brand Logo
    VALEGRO Chiller VALEGRO Chiller
  • Applications
    Applications & Markets
    Industries and markets
    • Automotive industry
    • Chemical process technology
    • Cannabis extraction
    • Temperature Control Systems in the Food Industry
    • Temperature Control Solutions in the Semiconductor Industry
    • Test of satellite components
    Case stories and applications
    • Material & component tests
    • Basic research
    • Quality test of separating clutches
    Case studies
    Highlights
    Automotive industry
    Semiconductor and electrical industry
  • Service
    Our services
    Consulting & project planning
    • Professional consultation
    • Comparison of refrigerants
    Sales & initial operation
    After-sales service
    • Repair & Service
    • Maintenance
    • Leak test
    • Warranty
    • Service training
    • On-site service
    Downloads
    • Catalogs and brochures
    • Safety data sheets
    • Software
    • Service manuals
    • Operating Manuals
    Highlights
    On-site service
    Maintenance
  • Know-How
  • Company
    News Sustainability & responsibility History Locations Quality Vision and values
  • Contact
    Contact form
  • Search
    Search for terms, products, order numbers, etc.
  • Select language
    Select region
    Europe
    • United Kingdom English
    • Deutschland Deutsch
    • France Français
    • Nederland Nederlands
    • Italia Italiano
    • Switzerland Deutsch  |  Français  |  Italiano
    Asia / Oceania
    • 日本 日本語
    • 中国 简体中文
    • 대한민국 한국어
    • Singapore English
    • Australia English
    • India English
    America
    • United States Englisch
    • Canada English  |  Français
    • Latin America Español  |  Português
    Language selection (all other countries)
    • Deutsch
    • English
    • Español
    • Français
    • Italiano
    • Nederlands
    • Português
    • Русский
JULABO refrigerated thermostat is operated in a laboratory by a laboratory technician
  •  
  • Home
  • Product Overview
  • Accessories
  • Adapters and Valves
  • Shut-off valve M16x1 in/out

Shut-off valve M16x1 in/out

Shut-off valves Shut-off valve M16x1 in/out view 1

Technical Data:

  • Shut-off valve with handle
  • Temperature range: -30°C...+200°C
  • Max. pressure: PN 56 bar
  • Material:
    • Body: 1.4408
    • Ball: 1.4401/316
    • Connection: 1.4408
    • Seal: PTFE glassfiber reinforced
    • Handle: stanlaiss steel plastic coated
  • Shut-off valve can be opened and closed over the entire temperature range
Order number 8970457
Shut-off valves Shut-off valve M16x1 in/out view 1
This accessory is suitable for:
  • DYNEO DD
  • DYNEO DD-1200F
  • DYNEO DD-1200FW
  • DYNEO DD-1201F
  • DYNEO DD-1201F-BF
  • DYNEO DD-200F
  • DYNEO DD-201F
  • DYNEO DD-310F
  • DYNEO DD-449F
  • DYNEO DD-450F
  • DYNEO DD-650F
  • DYNEO DD-800F
  • DYNEO DD-BC12
  • DYNEO DD-BC26
  • DYNEO DD-BC4
  • DYNEO DD-BC6
  • MAGIO MS-1000FF
  • MAGIO MS-1200F
  • MAGIO MS-1200FW
  • MAGIO MS-310F
  • MAGIO MS-449F
  • MAGIO MS-450F
  • MAGIO MS-650F
  • MAGIO MS-800F
  • MAGIO MS-BC4
  • MAGIO MS-Z
  • MAGIO MX-1800F
  • MAGIO MX-2500F
  • MAGIO MX-BC12
  • MAGIO MX-BC26
  • MAGIO MX-BC6
  • MAGIO MX-Z
  • CORIO CD
  • CORIO CD-1200F
  • CORIO CD-1200FW
  • CORIO CD-1201F
  • CORIO CD-200F
  • CORIO CD-201F
  • CORIO CD-310F
  • CORIO CD-449F
  • CORIO CD-450F
  • CORIO CD-650F
  • CORIO CD-800F
  • CORIO CD-B13
  • CORIO CD-B17
  • CORIO CD-B19
  • CORIO CD-B27
  • CORIO CD-B33
  • CORIO CD-B39
  • CORIO CD-B5
  • CORIO CD-BC12
  • CORIO CD-BC26
  • CORIO CD-BC4
  • CORIO CD-BC6
  • CORIO CD-BT19
  • CORIO CD-BT27
  • CORIO CD-BT5
  • CORIO CP
  • CORIO CP-1200F
  • CORIO CP-1200FW
  • CORIO CP-1201F
  • CORIO CP-200F
  • CORIO CP-201F
  • CORIO CP-310F
  • CORIO CP-449F
  • CORIO CP-450F
  • CORIO CP-650F
  • CORIO CP-800F
  • CORIO CP-BC12
  • CORIO CP-BC26
  • CORIO CP-BC4
  • CORIO CP-BC6
North America
Headquarters

JULABO USA, Inc.
884 Marcon Boulevard
Allentown, PA 18109
North America

+1 610-231-0250

Write an e-mail
https://julabo.us/

JULABO GmbH
Gerhard-Juchheim-Strasse 1
77960 Seelbach
Germany

+49 7823 51-0

Write an e-mail
www.julabo.com

  • Products
  • Applications
  • Service
  • News
  • Company
  • Contact
  • Trade fairs & exhibitions
  • Newsletter subscription
  • Press
  • Legal
  • Supplier information
  • Terms
  • Privacy Policy
Copyright © 2026 JULABO GmbH. All rights reserved.
  • Instagram
  • Facebook
  • LinkedIn
  • Xing
  • Youtube
  • Products
    • Refrigerated circulators
      • Refrigerated / Heating Circulators
      • Ultra-Low Refrigerated-Heating Circulators
    • Heating Circulators
      • Heating Immersion Circulators
      • Open heating bath circulators
      • Heating Circulators
      • Heating circulators with open bath
      • Bridge mounted circulators
    • Highly Dynamic Temperature Control Systems
      • PRESTO process systems
      • Forte HT High Temperature Circulators
    • Recirculating Coolers
      • VALEGRO Recirculating Coolers
      • VIGORO recirculating cooler
      • FL Recirculating coolers
      • Recirculating coolers without refrigerant
    • Water Baths
      • PURA water baths
    • Shaking Water Baths
      • SW Shaking Water Baths
    • Products for Special Applications
      • Immersion Coolers
      • Laboratory Temperature Controllers
      • Beer Forcing Test Refrigerated / Heating Circulating Baths
    • Accessories
    • Calibration baths
    • Used equipment
    • Customized special solutions
    • Product filter
  • Applications
    • Industries and markets
      • Automotive industry
      • Chemical process technology
      • Cannabis extraction
      • Temperature Control Systems in the Food Industry
      • Temperature Control Solutions in the Semiconductor Industry
      • Test of satellite components
    • Case stories and applications
      • Material & component tests
      • Basic research
      • Quality test of separating clutches
    • Case studies
  • Service
    • Consulting & project planning
      • Professional consultation
      • Comparison of refrigerants
    • Sales & initial operation
    • After-sales service
      • Repair & Service
      • Maintenance
      • Leak test
      • Warranty
      • Service training
      • On-site service
    • Downloads
      • Catalogs and brochures
      • Safety data sheets
      • Software
      • Service manuals
      • Operating Manuals
  • Know-How
  • Company
    • News
    • Sustainability & responsibility
    • History
    • Locations
    • Quality
    • Vision and values
  • Contact
    • Contact form
  • Select region
    • Europe
      • United Kingdom Englisch
      • Deutschland Deutsch
      • France Français
      • Nederland Nederlands
      • Italia Italiano
    • Asia / Oceania
      • 日本 日本語
      • 中国 简体中文
      • 대한민국 한국어
      • Singapore English
      • Australia English
      • India English
    • America
      • United States Englisch
      • Canada English Français
      • Latin America Español Português
    • Language selection (all other countries)
      • Deutsch
      • English
      • Espanol
      • Francais
      • Italiano
      • Nederlands
      • Portugues
      • Русский