FW95-SL Ultra-Low Refrigerated / Heating Circulator

for working temperatures below -50 °C to +150 °C with filling port upgradeable with additional heating and pump capacity for external control only

Ultra-Low Refrigerated Circulators with SL circulator impress with their high heating, cooling and pump capacities for external temperature control applications.

Data at mains voltage / frequency:
400V/3PNPE/50Hz (Plug 32A CEE)
FW95-SL
Order No. 9 352 796N
Working temperature range -95 °C
Temperature stability ±0.05 °C
Heating capacity 3 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
0 -20 -40 -60 -80
1.7 1.5 1.3 1.1 0.36
Cooling capacity
(Medium: Ethanol)
°C 0 -20 -40 -60 -80
kW 1.7 1.5 1.3 1.1 0.36
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 0.4 ... 0.7 bar
Filling volume 22 l
Dimensions
(W × L × H)
59 x 76 x 116 cm
FW95-SL
Order No. 9 352 796N
Working temperature range -95 °C
Temperature stability ±0.05 °C
Heating capacity 3 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
0 -20 -40 -60 -80
1.7 1.5 1.3 1.1 0.36
Cooling capacity
(Medium: Ethanol)
°C 0 -20 -40 -60 -80
kW 1.7 1.5 1.3 1.1 0.36
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 0.4 ... 0.7 bar
Filling volume 22 l
Dimensions
(W × L × H)
59 x 76 x 116 cm
FW95-SL
Order No. 9 352 796N
Working temperature range -95 °C
Temperature stability ±0.05 °C
Heating capacity 3 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
0 -20 -40 -60 -80
1.7 1.5 1.3 1.1 0.36
Cooling capacity
(Medium: Ethanol)
°C 0 -20 -40 -60 -80
kW 1.7 1.5 1.3 1.1 0.36
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 0.4 ... 0.7 bar
Filling volume 22 l
Dimensions
(W × L × H)
59 x 76 x 116 cm
Arrange callback Accessory

Product Features

  • VFD COMFORT DISPLAY
  • LCD DIALOG DISPLAY backlit for convenient interactive operation
  • Keypad for setpoints, warning/safety values and menu functions
  • ICC (Intelligent Cascade Control), self-optimizing temperature control
  • TCF Temperature Control Features to optimize the control behavior
  • ATC3 3-Point-Calibration
  • Pt100 External sensor connection for measurement and control
  • SMART PUMP, electronically adjustable pump stages
  • Adjustable high temperature cut-out, visible via display
  • RS232/RS485 interface for online communication
  • Integrated programmer for 6 x 60 program steps
  • Connections for solenoid valve and HSP booster pump
  • Proportional cooling control
Dimensions and volumes
Dimensions
(W × L × H)
59 x 76 x 116 cm
Filling volume 22 l
Weight 198 kg
Pump connections M16x1 male
Cooling Water Connection G¾ in
Temperature values
Working temperature range -95 °C
Temperature stability ±0.05 °C
Setting the resolution of the temperature display 0.01 °C
Temperature display resolution 0.01 °C
Ambient temperature +5.0 ... +40.0 °C
Data at mains voltage / frequency:
400V/3PNPE/50Hz (Plug 32A CEE)
Performance values
Heating capacity 3 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
0 -20 -40 -60 -80
1.7 1.5 1.3 1.1 0.36
Cooling capacity
(Medium: Ethanol)
°C 0 -20 -40 -60 -80
kW 1.7 1.5 1.3 1.1 0.36
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 0.4 ... 0.7 bar
Maximum suction 0.2 ... 0.4 bar
Viscosity max. 70 cST
Refrigerant stage 1
Refrigerant R404A
Global Warming Potential for R404A 3922
Filling volume 800 g
Carbon dioxide equivalent 3.138 t
Refrigerant stage 2
Refrigerant R23
Global Warming Potential for R23 14800
Filling volume 380 g
Carbon dioxide equivalent 5.624 t
Power 24 A
Performance values
Heating capacity 3 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
0 -20 -40 -60 -80
1.7 1.5 1.3 1.1 0.36
Cooling capacity
(Medium: Ethanol)
°C 0 -20 -40 -60 -80
kW 1.7 1.5 1.3 1.1 0.36
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 0.4 ... 0.7 bar
Maximum suction 0.2 ... 0.4 bar
Viscosity max. 70 cST
Refrigerant stage 1
Refrigerant R404A
Global Warming Potential for R404A 3922
Filling volume 800 g
Carbon dioxide equivalent 3.138 t
Refrigerant stage 2
Refrigerant R23
Global Warming Potential for R23 14800
Filling volume 380 g
Carbon dioxide equivalent 5.624 t
Power 28 A
Performance values
Heating capacity 3 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
0 -20 -40 -60 -80
1.7 1.5 1.3 1.1 0.36
Cooling capacity
(Medium: Ethanol)
°C 0 -20 -40 -60 -80
kW 1.7 1.5 1.3 1.1 0.36
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 0.4 ... 0.7 bar
Maximum suction 0.2 ... 0.4 bar
Viscosity max. 70 cST
Refrigerant stage 1
Refrigerant R404A
Global Warming Potential for R404A 3922
Filling volume 800 g
Carbon dioxide equivalent 3.138 t
Refrigerant stage 2
Refrigerant R23
Global Warming Potential for R23 14800
Filling volume 380 g
Carbon dioxide equivalent 5.624 t
Power 28 A
Bath
Bath cover integrated
Cooling
Cooling of compressor 2-stage Water
Cooling water pressure max. 6 bar
Cooling water difference pressure 3.5 ... 6 bar
Cooling water temperature max. 20 °C
Other
Classification
according to DIN12876-1
Classification III (FL)
IP Code
according to IEC 60529
IP 21
Electronics
Digital interface Profibus optional
External pt100 sensor connection integrated
Integrated programmer 6x60 steps
Temperature control ICC
Absolute temperature calibration 3 Point Calibration
Temperature display VFD
Temperature setting Keypad
Available voltage versions
400V/3PNPE/50Hz Plug 32A CEE 9352796N.07
208V/3PPE/60Hz Without Plug 9352796N.16
Included in delivery
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male)

Accessory for FW95-SL

Contact expert

We would also be happy to send you our printed catalogs and brochures by post.


Request brochure

Benefits

  • 100% geprüft
    100% Checked.
    100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.
  • Blatt wächst in einer Glühbirne
    Green technology.
    Development consistently applied environmentally friendly materials and technologies.
  • Made in Germany
    JULABO. Quality.
    Highest standards of quality for a long product life.
  • Quickstart
    Quick start.
    Individual JULABO consultation and comprehensive manuals at your disposal.