FP55-SL
Order No. see refrigerant options
Working temperature range -60 ... +150 °C
Temperature stability ±0.05 °C
Heating capacity 3 kW
Cooling capacity
Refrigerant variant
Order No. 9352755.07.N150
Cooling capacity Medium: Ethanol
°C 20 0 -20 -40 -50 -60
kW* 5.2
4.1
2.2
0.7
0.3
0.13
Refrigerant R452A
Global Warming Potential 2140
Filling volume 2000 g
Carbon dioxide equivalent 4.28 t
* All performance specifications measured in accordance with DIN12876 with ethanol, specifications over 20 °C measured with thermal oil unless otherwise specified.
Refrigerant variant .S1
Order No. 9352755.S1.07.N150
Cooling capacity Medium: Ethanol
°C 20 0 -20 -40 -50
kW* 5.4
4
2
0.7
0.3
Refrigerant R449A
Global Warming Potential 1397
Filling volume 2000 g
Carbon dioxide equivalent 2.794 t
* All performance specifications measured in accordance with DIN12876 with ethanol, specifications over 20 °C measured with thermal oil unless otherwise specified.
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 0.4 ... 0.7 bar
Filling volume 27 l
Dimensions
(W × L × H)
85 x 76 x 116 cm
Arrange callback Accessory

Product Features

  • VFD COMFORT DISPLAY
  • LCD DIALOG DISPLAY backlit for convenient interactive operation
  • Keypad for setpoints, warning/safety values and menu functions
  • ICC (Intelligent Cascade Control), self-optimizing temperature control
  • TCF Temperature Control Features to optimize the control behavior
  • ATC3 3-Point-Calibration
  • Pt100 External sensor connection for measurement and control
  • SMART PUMP, electronically adjustable pump stages
  • Adjustable high temperature cut-out, visible via display
  • RS232/RS485 interface for online communication
  • Integrated programmer for 6 x 60 program steps
  • Connections for solenoid valve and HSP booster pump
  • Proportional cooling control
Dimensions and volumes
Dimensions
(W × L × H)
85 x 76 x 116 cm
Filling volume 27 l
Weight 180 kg
Pump connections M16x1 male
Temperature values
Working temperature range -60 ... +150 °C
Temperature stability ±0.05 °C
Setting the resolution of the temperature display 0.01 °C
Temperature display resolution 0.01 °C
Ambient temperature +5.0 ... +40.0 °C

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Heating capacity 3 kW
Cooling capacity
Refrigerant variant
Order No. 9352755.07.N150
Cooling capacity Medium: Ethanol
°C 20 0 -20 -40 -50 -60
kW* 5.2
4.1
2.2
0.7
0.3
0.13
Refrigerant R452A
Global Warming Potential 2140
Filling volume 2000 g
Carbon dioxide equivalent 4.28 t
* All performance specifications measured in accordance with DIN12876 with ethanol, specifications over 20 °C measured with thermal oil unless otherwise specified.
Refrigerant variant .S1
Order No. 9352755.S1.07.N150
Cooling capacity Medium: Ethanol
°C 20 0 -20 -40 -50
kW* 5.4
4
2
0.7
0.3
Refrigerant R449A
Global Warming Potential 1397
Filling volume 2000 g
Carbon dioxide equivalent 2.794 t
* All performance specifications measured in accordance with DIN12876 with ethanol, specifications over 20 °C measured with thermal oil unless otherwise specified.
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 0.4 ... 0.7 bar
Maximum suction 0.2 ... 0.4 bar
Viscosity max. 70 cST
Power 20 A
Bath
Bath cover integrated
Cooling
Cooling of compressor Air
Other
Classification
according to DIN12876-1
Classification III (FL)
IP Code
according to IEC 60529
IP 21
Electronics
Digital interface Profibus optional
External pt100 sensor connection integrated
Integrated programmer 6x60 steps
Temperature control ICC
Absolute temperature calibration 3 Point Calibration
Temperature display VFD
Temperature setting Keypad
Available voltage versions
9352755.07.N150 400V/3PNPE/50Hz (Plug 32A CEE) (R452A)
9352755.S1.07.N150 400V/3PNPE/50Hz (Plug 32A CEE) (R449A)
9352755.16.N150 208V/3PPE/60Hz (Without Plug) (R452A)
Included in delivery
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male)

Accessory for FP55-SL

Contact expert

We would also be happy to send you our printed catalogs and brochures by post.


Request brochure

Benefits

  • 100% geprüft
    100% Checked.
    100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.
  • Blatt wächst in einer Glühbirne
    Green technology.
    Development consistently applied environmentally friendly materials and technologies.
  • Made in Germany
    JULABO. Quality.
    Highest standards of quality for a long product life.
  • Quickstart
    Quick start.
    Individual JULABO consultation and comprehensive manuals at your disposal.