Refrigerated - Heating Circulators

for working temperatures from -50 °C to +200 °C

JULABO Refrigerated and Heating Circulators are suitable for temperature application to external systems with simultaneous operation in the bath tank. Models in different performance classes are available. The units provide high heating/cooling capacities to ensure rapid heat-up and cool-down times. With ‚Active Cooling Control' to +200 °C (not on ED models). ‚FP‘ models offer proportional cooling control to ensure energy-saving performance and to reduce heat generation to the environment. Convenient cleaning of dust by removable venting grid. Some models have a handle or castors to allow easy transport. All models provide a drain port on the front for conveniently draining the bath fluid. Typical applications: Temperature applications to external, closed systems, such as for example photometers, refractometers, viscometers, etc. For simultaneous application to small objects in the circulator bath.

Product overview


CORIO new
Order No. Model Working temperature
range (°C)
Temperature stability
(°C)
Cooling capacity at 20 °C Heating capacity (kW) Pump capacity flow rate (l/min) Pump pressure (psi) Comparison
9012701 CORIO CD-200F -20 ... +150 ±0.03 0.22 1 15 5.08
9012702 CORIO CD-201F -20 ... +150 ±0.03 0.22 1 15 5.08
9012703 CORIO CD-300F -25 ... +150 ±0.03 0.31 1 15 5.08
9012704 CORIO CD-600F -35 ... +150 ±0.03 0.6 1 15 5.08
9012705 CORIO CD-601F -40 ... +150 ±0.03 0.6 1 15 4.8
9012706 CORIO CD-900F -40 ... +150 ±0.03 0.9 1 15 4.8
9012707 CORIO CD-1000F -40 ... +150 ±0.03 1 1 15 5.08
9012708 CORIO CD-1001F -38 ... +100 ±0.03 1 1.5 15

TopTech
Order No. Model Working temperature
range (°C)
Temperature stability
(°C)
Cooling capacity at 20 °C Heating capacity (kW) Pump capacity flow rate (l/min) Pump pressure (psi) Comparison
9153612 F12-MA -20 ... +200 ±0.02 0.16 1 11-16 3.3-6.5
9153618 FP35-MA -35 ... +150 ±0.02 0.45 1 11-16 3.3-6.5
9153625 F25-MA -28 ... +200 ±0.02 0.26 1 11-16 3.3-6.5
9153632 F32-MA -35 ... +200 ±0.02 0.45 1 11-16 3.3-6.5
9153633 F33-MA -30 ... +200 ±0.02 0.5 1 11-16 3.3-6.5
9153634 F34-MA -30 ... +150 ±0.02 0.45 1 11-16 3.3-6.5
9153640 FP40-MA -40 ... +200 ±0.02 0.68 2 11-16 3.3-6.5
9153650 FP50-MA -50 ... +200 ±0.02 0.9 2 11-16 3.3-6.5
9153651 FPW50-MA -50 ... +200 ±0.02 0.9 2 11-16 3.3-6.5
9162625 F25-ME -28 ... +200 ±0.01 0.26 1 11-16 3.3-6.5
9162626 F26-ME -28 ... +200 ±0.01 0.26 1 11-16 3.3-6.5
9162632 F32-ME -35 ... +200 ±0.01 0.45 1 11-16 3.3-6.5
9162633 F33-ME -30 ... +200 ±0.01 0.5 1 11-16 3.3-6.5
9162634 F34-ME -30 ... +150 ±0.01 0.45 1 11-16 3.3-6.5
9162640 FP40-ME -40 ... +200 ±0.01 0.68 2 11-16 3.3-6.5
9162650 FP50-ME -50 ... +200 ±0.01 0.9 2 11-16 3.3-6.5
9162651 FPW50-ME -50 ... +200 ±0.01 0.9 2 11-16 3.3-6.5

HighTech
Order No. Model Working temperature
range (°C)
Temperature stability
(°C)
Cooling capacity at 20 °C Heating capacity (kW) Pump capacity flow rate (l/min) Pump pressure (psi) Comparison
9212625 F25-HE -28 ... +200 ±0.01 0.26 1 22-26 5.8-10.2
9212632 F32-HE -35 ... +200 ±0.01 0.45 1 22-26 5.8-10.2
9212634 F34-HE -30 ... +150 ±0.01 0.45 1 22-26 5.8-10.2
9212640 FP40-HE -40 ... +200 ±0.01 0.68 2 22-26 5.8-10.2
9212650 FP50-HE -50 ... +200 ±0.01 0.9 2 22-26 5.8-10.2
9212651 FPW50-HE -50 ... +200 ±0.01 0.9 1 22-26 5.8-10.2
9312618 FP35-HL -35 ... +150 ±0.01 0.45 1 22-26 5.8-10.2
9312625 F25-HL -28 ... +200 ±0.01 0.26 1 22-26 5.8-10.2
9312632 F32-HL -35 ... +200 ±0.01 0.45 1 22-26 5.8-10.2
9312633 F33-HL -30 ... +200 ±0.01 0.5 1 22-26 5.8-10.2
9312640 FP40-HL -40 ... +200 ±0.01 0.68 2 22-26 5.8-10.2
9312650 FP50-HL -50 ... +200 ±0.01 0.9 2 22-26 5.8-10.2
9312651 FPW50-HL -50 ... +200 ±0.01 0.9 1 22-26 5.8-10.2