MAGIO MX-1800F Refrigerated / heating circulator new
Our most powerful laboratory circulators with the highest cooling and heating capacity
As with all circulators from the MAGIO range, the refrigerated circulators stand out thanks to their premium quality, high performance and intuitive operation. These devices provide extra powerful pressure and suction pumps and have an incredibly high heating output of 3 kW, enabling even more dynamic temperature control for external applications.
With a working temperature range of -50 ... +200 °C, the Refrigerated / heating circulator MAGIO MX-1800F delivers an outstanding cooling capacity of 1.87 kW at 20 °C despite its compact design.
This cooling machine works with natural, environmentally-friendly refrigerant and was developed with a focus on energy efficiency. This means significant savings on the operating costs for numerous applications, which also means rapid amortization of the procurement cost. At the same time, the lower energy consumption positively contributes to climate protection.
High resolution TFT touch display
The modern TFT touch display gives you all the important information at a glance. Three large, predefined main screens clearly display data and graphics with various application priorities. Menu navigation is self-explanatory, arranged by relevance to daily operations and easy to operate with the touch of a finger. The in-built help function provides detailed support in case of additional questions.
Order No. | 9033751.N1.33 | ||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -50 ... +200 °C | ||||||||||||||||||||||||||||||||||||
Temperature stability | ±0.01 °C | ||||||||||||||||||||||||||||||||||||
Heating capacity | 3 kW | ||||||||||||||||||||||||||||||||||||
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
|||||||||||||||||||||||||||||||||||||
Pump capacity flow pressure | 16 ... 31 l/min | ||||||||||||||||||||||||||||||||||||
Circulation capacity pressure | 3.5 ... 13.3 psi | ||||||||||||||||||||||||||||||||||||
Usable bath opening (W x L / D) |
7.1 x 5.1 / 7.9 in. | ||||||||||||||||||||||||||||||||||||
Filling volume | 6.5 ... 11 l | ||||||||||||||||||||||||||||||||||||
Dimensions
(W × L × H) |
15.7 x 19.7 x 33.9 in. |
Product Features
- USB connection
- Class III (FL) according to DIN 12876-1
- RS232 interface for online communication
- Integrated programmer
- Integrated external Pt100 connection
- Ethernet
- analog interfaces (accessory)
- Ideal for demanding external applications
- Simple control of complex applications
- Flow rate 16 ... 31 l / min, pressure 0.24 ... 0.92 bar, suction 0.03 ... 0.4 bar
- Continuously adjustable, extremely powerful pressure / suction pump
- Large, high-resolution TFT touch display with multilingual user interface
- Parts being in contact with the medium made of stainless steel
- Connections for solenoid valve
- Integrated pump connection M16×1
Technical data for MAGIO MX-1800F
Dimensions (W × L × H) |
15.7 x 19.7 x 33.9 in. |
---|---|
Filling volume | 6.5 ... 11 l |
Weight | 134.5 lbs |
Pump connections | M16x1 male |
Working temperature range | -50 ... +200 °C |
---|---|
Temperature stability | ±0.01 °C |
Setting the resolution of the temperature display | 0.01 °C |
Temperature display resolution | 0.01 °C |
Ambient temperature | +5 ... +40 °C |
Heating capacity | 3 kW | ||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
|||||||||||||||||||||||||||||||||||||
Pump capacity flow pressure | 16 ... 31 l/min | ||||||||||||||||||||||||||||||||||||
Circulation capacity pressure | 3.5 ... 13.3 psi | ||||||||||||||||||||||||||||||||||||
Maximum suction | -0.4 ... -5.8 psi | ||||||||||||||||||||||||||||||||||||
Viscosity max. | 70 cSt | ||||||||||||||||||||||||||||||||||||
Power consumption | 15 A |
Bath tank | Stainless steel |
---|---|
Bath cover | integrated |
Usable bath opening (W x L / D) |
7.1 x 5.1 / 7.9 in. |
Cooling of compressor | 1-stage Air |
---|
Classification according to DIN12876-1 |
Classification III (FL) |
---|---|
IP Code according to IEC 60529 |
IP 20 |
Pump function | Pressure Suction Pump |
Pump type | Immersion Pump |
User Interface Language | Chinese / Czech / Dutch / English / French / German / Italian / Japanese / Korean / Polish / Portuguese / Russian / Spanish / Turkish |
Interfaces | Ethernet / Modbus / RS232 / RS485 / Stakei / USB |
---|---|
External pt100 sensor connection | integrated |
Integrated programmer | 8x60 steps |
Temperature control | ICC |
Absolute temperature calibration | 10 Point Calibration |
Temperature display | 7" TFT Touchscreen |
Temperature setting | Touchscreen |
Electronic Timer h:min |
00:00 ... 99:59 |
9033751.N1.33 | 200-230V/50-60Hz (Nema N6-20 Plug) (R1270) |
---|
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male) |
Accessory for MAGIO MX-1800F
Downloads for MAGIO MX-1800F
We would also be happy to send you our printed catalogs and brochures by post.
Request brochureMAGIO MX-1800F Benefits
Intelligent temperature control.
Intelligent cascade control - automatic and self-optimizing adaptation of the PID control parameters with external stability of +/- 0.05 °C.
Many interfaces.
Straight-forward remote control, data management, and integration into process structures. USB, Ethernet, RS232, SD card, and alarm off are permanently integrated. Further interfaces available as accessories.
Touch display. Perfect operation.
With the touch display, the user always has an overview of all values and functions. The intuitive and multilingual menu structure enables perfect control.
Maximum safety.
Classification III according to DIN12876-1 enables safe operation, even with flammable fluids. Automatic switch-off in the event of high temperature or low liquid level.