CORIO CD-1200FW Refrigerated / heating circulator new
The new generation of laboratory circulators for routine work and standard tasks
Refrigerated / heating circulators of the CORIO CD series distinguish themselves with a great price-to-performance ratio. Durable and dependable, they are suitable for a wide range of standard and routine work in both laboratories and industrial environments.
Despite its very compact design, the water-cooled Refrigerated / heating circulator CORIO CD-1200FW, which has a working temperature range of -40 ... +150 °C, delivers a powerful cooling capacity of 1.25 kW at 20°C. Water-cooled systems are normally more efficient than air-cooled systems, as water has a higher specific heat capacity than air. In addition, they introduce far less waste heat into the environment, which helps create a pleasant working climate.
This cooling machine works with natural, environmentally-friendly refrigerant and was developed with a focus on energy efficiency. This means significant savings up to 70% on the operating costs for numerous applications, which also means rapid amortization of the procurement cost. At the same time, the lower energy consumption positively contributes to climate protection.
Overview
Technical data
Accessory & Services
Downloads
Performance data depends on the mains voltage in the country of use. Please select:
Country of use | Mains voltage | Plug | JULABO voltage version code
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.
Pump capacity flow pressure
15 l/min
Circulation capacity pressure
0.35 bar
Viscosity max.
50 cSt
Power consumption
11 A
Bath
Bath tank
Stainless steel
Bath cover
integrated
Usable bath opening (W x L / D)
18 x 13 / 15 cm
Cooling
Cooling of compressor
1-stage Water
Cooling water pressure max.
6 bar
Recommended cooling water properties
to provide full cooling capacity according to catalog values
Cooling water temperature range
30 °C
Cooling water difference pressure
0.3 bar
Cooling water consumption
1.1 l/min
Other
Classification according to DIN12876-1
Classification III (FL)
IP Code according to IEC 60529
IP 21
Pump function
Pressure Pump
Pump type
Immersion Pump
Electronics
Interfaces
USB
Temperature control
PID1
Absolute temperature calibration
1 Point Calibration
Temperature display
LED
Temperature setting
Keypad
Available voltage versions
9012728.N1.12
200V/50-60Hz (Nema N6-20 Plug) (R1270)
9012728.N1.03
230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F) (R1270)
9012728.N1.01
100V/50-60Hz (Nema N5-20 Plug) (R1270)
9012728.N1.05
230V/50Hz (CH Plug Type SEV 1011) (R1270)
9012728.N1.04
230V/50Hz (UK Plug Type BS1363A) (R1270)
9012728.N1.03.chn
230V/50Hz (CN Plug) (R1270)
9012728.N1.13
230V/60Hz (Nema N6-20 Plug) (R1270)
9012728.N1.02
115V/60Hz (Nema N5-20 Plug) (R1270)
Included in delivery
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male)
Very bright display makes it easy to read even from a distance.
Switch on. And off you go.
Intelligent operating concept. Ready for operation with just a few quick and easy steps.
Timer. Integrated.
CORIO circulators include an integrated timer function. When the set time has elapsed, a signal sounds and the device switches off. Setting range: 0 ... 999 minutes.
Everything at the front.
All operating controls and safety functions are accessed easily and comfortably from the front.