MAGIO laboratory circulators

With the new MAGIO series, JULABO is expanding its product portfolio of high-end bridge mounted circulators, refrigerated and heating circulators – naturally all in the usual premium quality. The circulators operate in a working temperature range from -50 °C to +300 °C and with a heating capacity of up to 3 kW. Excellent heating/cooling performance guarantees very short heat-up and cool-down times.

MAGIO Circulators - an overview of the categories

MAGIO MS refrigerated / heating circulators

with extremely powerful pressure/suction pump and intuitive touch display

As with all circulators from the MAGIO range, the refrigerated circulators stand out thanks to their premium quality, high performance and intuitive operation. The devices offer extra strong pressure and suction pumps, thus fulfilling the highest demands for temperature control of external applications. Whether in basic research, material testing or technical systems – the MAGIO refrigerated circulators offer high-tech solutions for high customer requirements.

Model
Add to compare
MAGIO MS-310F
Add to compare
MAGIO MS-449F
Add to compare
MAGIO MS-450F
Add to compare
MAGIO MS-600F
Working temperature range (°C) -30 ... +200 -30 ... +200 -30 ... +200 -35 ... +200
Temperature stability (°C) ±0.01 ±0.01 ±0.01 ±0.01
Cooling capacity (kW) 0.33 0.46 0.46 0.6
Heating capacity (kW) 2 2 2 2
Pump capacity flow pressure (l/min) 16 ... 31 16 ... 31 16 ... 31 16 ... 31
Circulation capacity pressure (bar) 0.24 ... 0.92 0.24 ... 0.92 0.24 ... 0.92 0.24 ... 0.92
Model
Add to compare
MAGIO MS-601F
Add to compare
MAGIO MS-800F
Add to compare
MAGIO MS-1000F
Add to compare
MAGIO MS-1000FW
Working temperature range (°C) -35 ... +200 -40 ... +200 -50 ... +200 -50 ... +200
Temperature stability (°C) ±0.01 ±0.01 ±0.01 ±0.01
Cooling capacity (kW) 0.6 0.86 1 1
Heating capacity (kW) 2 2 2 2
Pump capacity flow pressure (l/min) 16 ... 31 16 ... 31 16 ... 31 16 ... 31
Circulation capacity pressure (bar) 0.24 ... 0.92 0.24 ... 0.92 0.24 ... 0.92 0.24 ... 0.92
Model
Add to compare
MAGIO MS-1200F
Add to compare
MAGIO MS-1200FW
Working temperature range (°C) -50 ... +200 -50 ... +200
Temperature stability (°C) ±0.01 ±0.01
Cooling capacity (kW) 1.26 1.26
Heating capacity (kW) 2 2
Pump capacity flow pressure (l/min) 16 ... 31 16 ... 31
Circulation capacity pressure (bar) 0.24 ... 0.92 0.24 ... 0.92

MAGIO MS and MX bridge mounted circulators

with extremely powerful pump and intuitive touch display

MAGIO bridge mounted circulators combine high temperature control performance with maximum flexibility. The adjustable bridge means that the circulators can be used with bath tanks up to a filling volume of 100 liters.

Model
Add to compare
MAGIO MS-Z
Add to compare
MAGIO MX-Z
Working temperature range (°C) +20 ... +300 +20 ... +300
Temperature stability (°C) ±0.01 ±0.01
Heating capacity (kW) 2 3
Pump capacity flow pressure (l/min) 16 ... 31 16 ... 31
Circulation capacity pressure (bar) 0.24 ... 0.92 0.24 ... 0.92

MAGIO MS / MX heating circulators

with extremely powerful pumps, intuitive touchscreen displays

Like all circulators in the MAGIO range, the heating circulators are characterised by premium quality and high performance combined with intuitive usability. The devices offer extra powerful pressure and suction pumps to meet the most challenging demands for temperature control of external applications. Samples can also be temperature controlled in the internal bath of the high-quality, insulated and closed bath tank.

Model
Add to compare
MAGIO MS-BC4
Add to compare
MAGIO MX-BC6
Add to compare
MAGIO MX-BC12
Add to compare
MAGIO MX-BC26
Working temperature range (°C) +20 ... +300 +20 ... +300 +20 ... +300 +20 ... +300
Temperature stability (°C) ±0.01 ±0.01 ±0.01 ±0.01
Heating capacity (kW) 2 3 3 3
Pump capacity flow pressure (l/min) 16 ... 31 16 ... 31 16 ... 31 16 ... 31
Circulation capacity pressure (bar) 0.24 ... 0.92 0.24 ... 0.92 0.24 ... 0.92 0.24 ... 0.92