Print












FP35-MA Refrigerated/Heating Circulator
The general all-rounder for a broad spectrum of requirements
JULABO Refrigerated & Heating Circulators for heating and cooling are suitable for external temperature tasks and for temperature applications directly in the bath. A model from three different series’ with different capacities can be selected. Powerful circulating pump systems and high heating and cooling capacities guarantee short heat-up and cool-down times. The inevitable dust accumulation that occurs in refrigeration systems is solved by means of an easily removed venting grid, which allows for easy cleaning. Depending on the model, the units are equipped with handles or castors for an easy transportation. All models have a drain screw on the front allowing the fluid to be drained easily. The compact assembly of each unit enables space to be saved in the laboratory.
Your advantages
- MULTI-DISPLAY (LED) for actual and setpoint values, warning/safety functions and pump stage
- Keypad for setpoints, warning/safety values and menu functions
- PID2 temperature control with drift compensation
- ATC3 3-Point-Calibration
- Early warning system for low liquid level (DBGM 203 06 059.8)
- Adjustable high temperature cut-out, visible via display
- RS232 interface for online communication
- SMART PUMP electronically adjustable pump stages
- Active Cooling Control
Technical Data
| Order No. | 9153618 | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Model series | TopTech | ||||||||
| Category | Refrigerated - Heating Circulators | ||||||||
| Working temperature range (°C) | -35 ... +150 | ||||||||
| Temperature control | PID | ||||||||
| Temperature stability (°C) | ±0.02 | ||||||||
| Setting / display resolution | 0.01 (-9.99...99.99) / 0.1 °C | ||||||||
| Temperature Display | LED | ||||||||
| Heating capacity (kW) | 1 | ||||||||
| Cooling capacity (Medium Ethanol) |
|
||||||||
| Pump capacity flow rate (l/min) | 11-16 | ||||||||
| Pump capacity flow pressure (psi) | 3.3-6.5 | ||||||||
| Bath opening / bath depth (W x L / D inch) | 7.1 x 4.7 / -- | ||||||||
| Pump connections | M10x1 | ||||||||
| Barbed fittings diameter (inner dia. / mm) | 8 / 10 | ||||||||
| Filling volume (liters) | 2.5 | ||||||||
| Refrigerant stage 1 | R134a | ||||||||
| Filling volume refrigerant stage 1 (g) | 190 | ||||||||
| Global Warming Potential for | 1430 | ||||||||
| Carbon dioxide equivalent stage 1 (t) | 0.272 | ||||||||
| Digital interfaces |
RS232 Optional Profibus |
||||||||
| Ambient temperature | 5...40 °C | ||||||||
| Dimensions W x L x H (inch) | 12.2 x 16.5 x 25.2 | ||||||||
| Weight (LBS) | 81 | ||||||||
| Classification according to DIN12876-1 | Classification III (FL) | ||||||||
| Included with each unit | 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) | ||||||||
| Cooling of compressor | Air | ||||||||
| Power requirement V / Hz / A | 115/60/14 Additional voltage versions available |
Characteristics
Display
Several values at a glance
Large Multi-Display (LED), easy to read across the room, for actual value and up to 3 setpoints, warning functions, high temperature cut-off, selected pump stages (resolution 0.01/0.1 °C)
Large Multi-Display (LED), easy to read across the room, for actual value and up to 3 setpoints, warning functions, high temperature cut-off, selected pump stages (resolution 0.01/0.1 °C)
Operation
Comfortable and detailed
Comfortable keypad with additional menu functions for pump stages, calibration, control parameters, programmer, warnings, etc.
Comfortable keypad with additional menu functions for pump stages, calibration, control parameters, programmer, warnings, etc.
Temperature Control
Highly precise
PID Temperature control with drift compensation and adjustable control parameters, temperature stability ±0.01...±0.02 °C
PID Temperature control with drift compensation and adjustable control parameters, temperature stability ±0.01...±0.02 °C
Highest measuring accuracy
‘Absolute Temperature Calibration’ for manual compensation of a temperature difference, 3-point calibration
‘Absolute Temperature Calibration’ for manual compensation of a temperature difference, 3-point calibration
Refrigeration Technology
Energy saving cooling
Proportional cooling control for automatic adjustment of cooling power or temporary switch-off of compressor as needed to save up to 90 % energy in comparison to unregulated cooling machines
Proportional cooling control for automatic adjustment of cooling power or temporary switch-off of compressor as needed to save up to 90 % energy in comparison to unregulated cooling machines
Consistent cooling capacity
Easily removable venting grid for quick and easy cleaning
Easily removable venting grid for quick and easy cleaning
100 % Cooling capacity
‘Active Cooling Control’ for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures
‘Active Cooling Control’ for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures
Technical Features
Clever pump system
Reliable and consistent pump capacity, electronically adjustable pump stages
Reliable and consistent pump capacity, electronically adjustable pump stages
Serial connection
RS232 interface for PC connection, e.g. for data communication and recording of measured values
RS232 interface for PC connection, e.g. for data communication and recording of measured values
Warning & Safety Functions
Early warning system for low liquid level
Maximum safety for applications, optical and audible alarm, allows user to refill bath fluid before the unit shuts down
Maximum safety for applications, optical and audible alarm, allows user to refill bath fluid before the unit shuts down
Early warning system for high/low temperature limits
Maximum safety for applications, optical and audible alarm, convertible to automated cut-off function
Maximum safety for applications, optical and audible alarm, convertible to automated cut-off function
Enhanced protective functions
Maximum safety, adjustable high temperature cut-off or dry-running protection, additional display of setpoints permits easy and precise adjustments
Maximum safety, adjustable high temperature cut-off or dry-running protection, additional display of setpoints permits easy and precise adjustments
For flammable bath fluids
Classification III (FL) according to DIN 12876-1
Classification III (FL) according to DIN 12876-1
Other characteristics
Removable venting grid for convenient cleaning to maintain cooling performance.
Technical changes without prior notification.
Images may deviate from the original.
We would be pleased to submit a non-binding offer for the selected product or answer all pertinent questions.
click here for quotation request FP35-MASearch
Contact
JULABO USA Inc.
884 Marcon Boulevard
Allentown, PA 18109
Phone: 610-231-0250
Phone: 800-458-5226
(Toll-Free)
sales@julabo.us
julabo.us
Contact form
Downloads
Download centerAvailable voltage versions
Model: FP35-MA
Order No.: 9153618
230 V / 50 Hz
115 V / 60 Hz
100 V / 50-60 Hz
Order No.: 9153618
230 V / 50 Hz
115 V / 60 Hz
100 V / 50-60 Hz

