Print














F25-ME Refrigerated/Heating Circulator
The advanced all-rounder with a Pt100 external sensor connection
JULABO Refrigerated and Heating Circulators are suitable for temperature application to external systems with simultaneous operation in the bath tank. Models in different performance classes are available. The units provide high heating/cooling capacities to ensure rapid heat-up and cool-down times. With ‚Active Cooling Control' to +200 °C (not on ED models). ‚FP‘ models offer proportional cooling control to ensure energy-saving performance and to reduce heat generation to the environment. Convenient cleaning of dust by removable venting grid. Some models have a handle or castors to allow easy transport. All models provide a drain port on the front for conveniently draining the bath fluid. Typical applications: Temperature applications to external, closed systems, such as for example photometers, refractometers, viscometers, etc. For simultaneous application to small objects in the circulator bath.
Your advantages
- VFD COMFORT DISPLAY
- Keypad for setpoints, warning/safety values and menu functions
- PID3 cascade temperature control
- ATC3 3-Point-Calibration
- Pt100 External sensor connection for measurement and control
- SMART PUMP, electronically adjustable pump stages
- Early warning system for low liquid level (DBGM 203 06 059.8)
- Adjustable high temperature cut-out, visible via display
- RS232 interface for online communication
- Integrated programmer for 10 program steps
- Active Cooling Control
Technical Data
| Order No. | 9162625 | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Model series | TopTech | ||||||||
| Category | Refrigerated - Heating Circulators | ||||||||
| Working temperature range (°C) | -28 ... +200 | ||||||||
| Temperature control | PID, cascade | ||||||||
| Temperature stability (°C) | ±0.01 | ||||||||
| Setting / display resolution | 0.01 °C | ||||||||
| Integrated programmer | 1x10 steps | ||||||||
| Temperature Display | VFD | ||||||||
| Heating capacity (kW) | 1 | ||||||||
| Cooling capacity (Medium Ethanol) |
|
||||||||
| Pump capacity flow rate (l/min) | 11-16 | ||||||||
| Pump capacity flow pressure (psi) | 3.3-6.5 | ||||||||
| Bath opening / bath depth (W x L / D inch) | 4.7 x 5.5 / 5.5 | ||||||||
| Pump connections | M10x1 | ||||||||
| Barbed fittings diameter (inner dia. / mm) | 8 / 10 | ||||||||
| Filling volume (liters) | 4.5 | ||||||||
| Refrigerant stage 1 | R134a | ||||||||
| Filling volume refrigerant stage 1 (g) | 84 | ||||||||
| Global Warming Potential for | 1430 | ||||||||
| Carbon dioxide equivalent stage 1 (t) | 0.12 | ||||||||
| External Pt100 sensor connection | integrated | ||||||||
| Digital interfaces |
RS232 Optional Profibus |
||||||||
| Ambient temperature | 5...40 °C | ||||||||
| Dimensions W x L x H (inch) | 9.1 x 16.5 x 24 | ||||||||
| Weight (LBS) | 68 | ||||||||
| Classification according to DIN12876-1 | Classification III (FL) | ||||||||
| Included with each unit | 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) | ||||||||
| Cooling of compressor | Air | ||||||||
| Power requirement V / Hz / A | 115/60/13 Additional voltage versions available |
Characteristics
Display
A perfect view
Ample, easy to read VFD Comfort display for simultaneous display of 3 values, warning functions, high temperature cut-off, pump stages (resolution 0.01 °C)
Ample, easy to read VFD Comfort display for simultaneous display of 3 values, warning functions, high temperature cut-off, pump stages (resolution 0.01 °C)
Pump stage and liquid level
Backlit indicator for selected pump stages and filling volume on Presto® PLUS, Magnum 91 & Forte HT
Backlit indicator for selected pump stages and filling volume on Presto® PLUS, Magnum 91 & Forte HT
Operation
Comfortable and detailed
Comfortable keypad with additional menu functions for pump stages, calibration, control parameters, programmer, warnings, etc.
Comfortable keypad with additional menu functions for pump stages, calibration, control parameters, programmer, warnings, etc.
Temperature Control
For higher demands
PID Temperature control with drift compensation and adjustable parameters, improved temperature stability for external applications, temperature stability ±0.01 °C internal, <±0.1 °C external
PID Temperature control with drift compensation and adjustable parameters, improved temperature stability for external applications, temperature stability ±0.01 °C internal, <±0.1 °C external
Highest measuring accuracy
‘Absolute Temperature Calibration’ for manual compensation of a temperature difference, 3-point calibration
‘Absolute Temperature Calibration’ for manual compensation of a temperature difference, 3-point calibration
Refrigeration Technology
Consistent cooling capacity
Easily removable venting grid for quick and easy cleaning
Easily removable venting grid for quick and easy cleaning
100 % Cooling capacity
‘Active Cooling Control’ for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures
‘Active Cooling Control’ for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures
Technical Features
Clever pump system
Reliable and consistent pump capacity, electronically adjustable pump stages
Reliable and consistent pump capacity, electronically adjustable pump stages
Control from the external application
External Pt100 sensor connection for precise measurement and control directly in the external application
External Pt100 sensor connection for precise measurement and control directly in the external application
Serial connection
RS232 interface for PC connection, e.g. for data communication and recording of measured values
RS232 interface for PC connection, e.g. for data communication and recording of measured values
Easy program control
Integrated programmer for the execution of time and temperature dependant profiles, 1 temperature profile with 10 steps max., with real time clock
Integrated programmer for the execution of time and temperature dependant profiles, 1 temperature profile with 10 steps max., with real time clock
Warning & Safety Functions
Early warning system for low liquid level
Maximum safety for applications, optical and audible alarm, allows user to refill bath fluid before the unit shuts down
Maximum safety for applications, optical and audible alarm, allows user to refill bath fluid before the unit shuts down
Early warning system for high/low temperature limits
Maximum safety for applications, optical and audible alarm, convertible to automated cut-off function
Maximum safety for applications, optical and audible alarm, convertible to automated cut-off function
Enhanced protective functions
Maximum safety, adjustable high temperature cut-off or dry-running protection, additional display of setpoints permits easy and precise adjustments
Maximum safety, adjustable high temperature cut-off or dry-running protection, additional display of setpoints permits easy and precise adjustments
For flammable bath fluids
Classification III (FL) according to DIN 12876-1
Classification III (FL) according to DIN 12876-1
Other characteristics
Removable venting grid for convenient cleaning to maintain cooling performance.
Technical changes without prior notification.
Images may deviate from the original.
We would be pleased to submit a non-binding offer for the selected product or answer all pertinent questions.
click here for quotation request F25-MESearch
Contact
JULABO USA Inc.
884 Marcon Boulevard
Allentown, PA 18109
Phone: 610-231-0250
Phone: 800-458-5226
(Toll-Free)
sales@julabo.us
julabo.us
Contact form
Downloads
Download centerAvailable voltage versions
Model: F25-ME
Order No.: 9162625
230 V / 50 Hz
115 V / 60 Hz
100 V / 50-60 Hz
230 V / 60 Hz
Order No.: 9162625
230 V / 50 Hz
115 V / 60 Hz
100 V / 50-60 Hz
230 V / 60 Hz



