Print
CORIO CD-201F Refrigerated/Heating Circulator New
The new generation of laboratory circulators for routine work and standard tasks
Refrigerated / Heating Circulators of the new CORIO™ series distinguish themselves with a great price-to-performance ratio. They are ideal for all standard tasks and routine work in laboratories and industry.
Your advantages
- Models for internal and external applications
- Bright, white, easy to read display
- Very quiet
- Easy pump change-over (internal and external circulation)
- External pump connections (M16x1)
- USB connection
- Space-saving cooling coil design yields more usable space in the bath tank
- Bath lid and drain tap included
- Removable ventilation grid
- Refrigeration unit without side vents
- Class III (FL) according to DIN 12876-1
Technical Data
| Order No. | 9012702 | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Model series | CORIO | ||||||||
| Category | Refrigerated - Heating Circulators | ||||||||
| Working temperature range (°C) | -20 ... +150 | ||||||||
| Temperature control | PID | ||||||||
| Temperature stability (°C) | ±0.03 | ||||||||
| Setting / display resolution | 0.01 – 0-1 °C | ||||||||
| Temperature Display | LED | ||||||||
| Heating capacity (kW) | 1 | ||||||||
| Cooling capacity (Medium Ethanol) |
|
||||||||
| Pump capacity flow rate (l/min) | 15 | ||||||||
| Pump capacity flow pressure (psi) | 5.08 | ||||||||
| Bath opening / bath depth (W x L / D inch) | 5.1 x 5.9 / 5.9 | ||||||||
| Pump connections | M16x1 | ||||||||
| Barbed fittings diameter (inner dia. / mm) | 8 / 12 | ||||||||
| Filling volume (liters) | 3 ... 4 | ||||||||
| Refrigerant stage 1 | R134a | ||||||||
| Filling volume refrigerant stage 1 (g) | 70 | ||||||||
| Global Warming Potential for | 1430 | ||||||||
| Carbon dioxide equivalent stage 1 (t) | 0.1 | ||||||||
| Ambient temperature | 5...40 °C | ||||||||
| Dimensions W x L x H (inch) | 17.4 x 16.2 x 17.4 | ||||||||
| Weight (LBS) | 55.2 | ||||||||
| Included with each unit | 2 each barbed fitting for tubing 8 and 12 mm inner dia. (pump connections M16x1 male) | ||||||||
| Bath tank | Stainless steel | ||||||||
| Bath cover | integrated | ||||||||
| Cooling of compressor | Air |
100% Checked.
100% testing. 100% quality. Each CORIO undergoes thorough quality testing before leaving the factory.
100% testing. 100% quality. Each CORIO undergoes thorough quality testing before leaving the factory.
ATC.
Absolute Temperature Calibration, 1-point calibration (CD).
Absolute Temperature Calibration, 1-point calibration (CD).
Brilliant.
Bright display with strong illumination can be viewed easily from a long distance.
Bright display with strong illumination can be viewed easily from a long distance.
Click.
One for all. Control the circulator and the refrigeration unit with only one power switch.
One for all. Control the circulator and the refrigeration unit with only one power switch.
Condensation protection.
Superb design solution. Integrated ventilation directs air over the bath lid and minimizes condensation.
Superb design solution. Integrated ventilation directs air over the bath lid and minimizes condensation.
Connection. Easy.
Inclined pump connections (M16x1) facilitate the connection of applications. Each unit includes 2 barbed fittings of 8/12 mm diameter each.
Inclined pump connections (M16x1) facilitate the connection of applications. Each unit includes 2 barbed fittings of 8/12 mm diameter each.
Everything at the front.
All operating controls and safety functions are accessed easily and comfortably from the front.
All operating controls and safety functions are accessed easily and comfortably from the front.
Exact.
You can rely on it. PID1 control and 'Active Cooling Control' make the new CORIO precise and perfect.
You can rely on it. PID1 control and 'Active Cooling Control' make the new CORIO precise and perfect.
Green technology.
Development consistently applied environmentally friendly materials and technologies.
Development consistently applied environmentally friendly materials and technologies.
Handle with ease.
Makes day-to-day work easy. Comfortably move your CORIO around by using the ergonomic handles (front and rear).
Makes day-to-day work easy. Comfortably move your CORIO around by using the ergonomic handles (front and rear).
Internal. External.
The pump is controlled via a lever located directly below the display. Easily change between internal and external circulation.
The pump is controlled via a lever located directly below the display. Easily change between internal and external circulation.
JULABO. Quality.
Highest standards of quality for a long product life.
Highest standards of quality for a long product life.
Locked in.
The lockable power plug guarantees safe connection. More process safety.
The lockable power plug guarantees safe connection. More process safety.
Mobile.
Extra easy handling. Integrated castors for easy repositioning of refrigerated circulators. (CD-600F, CD-601F, CD-900F, CD-1000F, CD-1001F)
Extra easy handling. Integrated castors for easy repositioning of refrigerated circulators. (CD-600F, CD-601F, CD-900F, CD-1000F, CD-1001F)
Modern. Reliable.
Every JULABO Circulator is equipped with high-grade components like i.e. platinum sensors, proven motor technology, CAN-Bus communication and much more.
Every JULABO Circulator is equipped with high-grade components like i.e. platinum sensors, proven motor technology, CAN-Bus communication and much more.
More bath.
Designed for more comfort. Thanks to the recessed cooling coil, the internal bath provides more space.
Designed for more comfort. Thanks to the recessed cooling coil, the internal bath provides more space.
Quick start.
Individual JULABO consultation and comprehensive manuals at your disposal.
Individual JULABO consultation and comprehensive manuals at your disposal.
Safety.
CORIO CD complies with Class III (FL) according to DIN 12876-1 and switches off automatically in case of high temperature or low liquid level alarm.
CORIO CD complies with Class III (FL) according to DIN 12876-1 and switches off automatically in case of high temperature or low liquid level alarm.
Satisfied customers.
11 subsidiaries and more than 100 partners worldwide guarantee fast and qualified JULABO support.
11 subsidiaries and more than 100 partners worldwide guarantee fast and qualified JULABO support.
Services 24/7.
Around the clock availability. You can find suitable accessories, data sheets, manuals, case studies, and more at www.julabo.com.
Around the clock availability. You can find suitable accessories, data sheets, manuals, case studies, and more at www.julabo.com.
Solid.
Minimized energy loss through high-quality insulation.
Minimized energy loss through high-quality insulation.
Space saving. Free up space.
Place your JULABO Circulator right next to an application, another unit, or wall. That saves space. This is made possible by eliminating vents and connections on the sides.
Place your JULABO Circulator right next to an application, another unit, or wall. That saves space. This is made possible by eliminating vents and connections on the sides.
Stable.
Rubber feet allow for a secured footing of your CORIO to prevent damage to your laboratory equipment.
Rubber feet allow for a secured footing of your CORIO to prevent damage to your laboratory equipment.
Switch on. And off you go.
Intelligent operating concept. Ready for operation with just a few quick and easy steps.
Intelligent operating concept. Ready for operation with just a few quick and easy steps.
Tidy.
The special drain tap for easy draining of bath fluids without tools.
The special drain tap for easy draining of bath fluids without tools.
Touching permitted.
Optimum safety. The ergonomic plastic handle protects your fingers from hot surfaces.
Optimum safety. The ergonomic plastic handle protects your fingers from hot surfaces.
Unique.
Specially designed pyramids ensure that the condensed liquid drips directly back into the bath.
Specially designed pyramids ensure that the condensed liquid drips directly back into the bath.
USB.
Remote control made easy. CORIO CD circulators feature a USB connection.
Remote control made easy. CORIO CD circulators feature a USB connection.
Technical changes without prior notification.
Images may deviate from the original.
We would be pleased to submit a non-binding offer for the selected product or answer all pertinent questions.
click here for quotation request CORIO CD-201FSearch
Contact
JULABO USA Inc.
884 Marcon Boulevard
Allentown, PA 18109
Phone: 610-231-0250
Phone: 800-458-5226
(Toll-Free)
sales@julabo.us
julabo.us
Contact form
Available voltage versions
Model: CORIO CD-201F
Order No.: 9012702
230 V / 50 Hz
208 V - 230 V / 60 Hz
115 V / 60 Hz
100 V / 50-60 Hz
Order No.: 9012702
230 V / 50 Hz
208 V - 230 V / 60 Hz
115 V / 60 Hz
100 V / 50-60 Hz





