ME-18V Visco Bath
Visco Bath for internal temperature applications
JULABO Visco Baths are used for precise temperature applications with capillary viscometers and density meters within the bath tank. The units offer high temperature accuracy and optimal temperature distribution throughout the bath. An integral cooling coil for cooling water is provided for temperature applications below or near ambient temperatures. The units are equipped with a holder for thermometers and therefore offer very good options for temperature calibration procedures and comparisons with accredited thermometers.
Your advantages
- VFD COMFORT DISPLAY
- Keypad for setpoints, warning/safety values and menu functions
- PID3 cascade temperature control
- ATC3 3-Point-Calibration
- Pt100 External sensor connection for measurement and control
- SMART PUMP, electronically adjustable pump stages
- Early warning system for low liquid level (DBGM 203 06 059.8)
- Adjustable high temperature cut-out, visible via display
- RS232 interface for online communication
- Integrated programmer for 10 program steps
- Instruments can be used according to ASTM standard D445
Technical Data
| Order No. | 9162518 |
|---|---|
| Model series | TopTech |
| Category | Visco Baths |
| Working temperature range (°C) | +20 ... +150 |
| Temperature stability (°C) | ±0.01 |
| Setting / display resolution | 0.01 °C |
| Integrated programmer | 1x10 steps |
| Temperature Display | VFD |
| Heating capacity (kW) | 2 |
| Pump capacity flow rate (l/min) | 11-16 |
| Pump capacity flow pressure (psi) | 3.34...6.53 |
| Bath opening / bath depth (W x L / D inch) | 3.5 x 3.5 (2x) / 14.6 |
| Filling volume (liters) | 18 |
| External Pt100 sensor connection | integrated |
| Digital interfaces |
RS232 Optional Profibus |
| Ambient temperature | 5...40 °C |
| Dimensions W x L x H (inch) | 14.2 x 9.4 x 21.3 |
| Weight (LBS) | 37 |
| Classification according to DIN12876-1 | Classification III (FL) |
| Cooling coil | integrated |
| Bath tank | Stainless steel |
| Power requirement V / Hz / A | 115/60/9 Additional voltage versions available |
| Number of viscometers | 2 |
Characteristics
Ample, easy to read VFD Comfort display for simultaneous display of 3 values, warning functions, high temperature cut-off, pump stages (resolution 0.01 °C)
Backlit indicator for selected pump stages and filling volume on Presto® PLUS, Magnum 91 & Forte HT
Comfortable keypad with additional menu functions for pump stages, calibration, control parameters, programmer, warnings, etc.
PID Temperature control with drift compensation and adjustable parameters, improved temperature stability for external applications, temperature stability ±0.01 °C internal, <±0.1 °C external
‘Absolute Temperature Calibration’ for manual compensation of a temperature difference, 3-point calibration
Easily removable venting grid for quick and easy cleaning
‘Active Cooling Control’ for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures
Reliable and consistent pump capacity, electronically adjustable pump stages
External Pt100 sensor connection for precise measurement and control directly in the external application
RS232 interface for PC connection, e.g. for data communication and recording of measured values
Integrated programmer for the execution of time and temperature dependant profiles, 1 temperature profile with 10 steps max., with real time clock
Maximum safety for applications, optical and audible alarm, allows user to refill bath fluid before the unit shuts down
Maximum safety for applications, optical and audible alarm, convertible to automated cut-off function
Maximum safety, adjustable high temperature cut-off or dry-running protection, additional display of setpoints permits easy and precise adjustments
Classification III (FL) according to DIN 12876-1
Other characteristics
Bath cover with 4 round openings 51 mm dia. available as accessory (order no. 8 970 294).
Technical changes without prior notification.
Images may deviate from the original.
We would be pleased to submit a non-binding offer for the selected product or answer all pertinent questions.
click here for quotation request ME-18VSearch
Contact
JULABO USA Inc.
884 Marcon Boulevard
Allentown, PA 18109
Phone: 610-231-0250
Phone: 800-458-5226
(Toll-Free)
sales@julabo.us
julabo.us
Contact form
Downloads
Download centerAvailable voltage versions
Order No.: 9162518
208 - 230 V / 50 - 60 Hz
100 - 115 V / 50 - 60 Hz