Print

Water Bath

The PURA water bath from JULABO sets new standards of performance with innovative technologies that leave conventional water baths behind. Users enjoy numerous benefits in their daily work. JULABO engineers prioritized innovative functionality, a cutting-edge design, and the use of completely novel technologies as early as the conceptualization phase of development. The results are nothing short of brilliant. A PURA water bath will streamline the daily routines in your laboratory with innovative functionality.
All PURA water baths have an integrated drain tap. Enameled and glass-hard parts in the bath itself are highly durable and - most importantly - hygienically clean. Polycarbonate sidewalls have better insulating properties than stainless steel and are less conductive, but are equal to stainless steel in terms of cleanliness and hygiene. Operating the water bath is very straightforward and the bright, white LED display is easy to read, even from a distance. USB data communication is a standard feature.
Enameled surfaces provide optimal hygienic protection because bacteria and other microorganisms are unable to breed in the water bath. Biofilm never has a chance to get a foothold. The enameled surfaces are as hard as glass and highly scratch resistant, giving them a long service life. Dirt does not adhere to the surfaces, so cleaning the water baths is very easy.

Strong Benefits

  • Working temperature range from +18 °C to +99.9 °C
  • Models with filling volumes from 4.8 to 30 L
  • Temperature stability of ± 0.2 °C
  • Heating capacity up to 2 kW
  • Bright display
  • Mains switch is protected against spray water
  • Integrated protection against running dry

Product overview


PURA new
Order No. Model Working temperature
range (°C)
Temperature stability
(°C)
Heating capacity (kW) Füllvolumen (l) Bath opening Comparison
9550404 PURA 4 +18 ... +99.9 ±0.2 0.8 0.4 ... 4.8 12 x 27 / 17
9550410 PURA 10 +18 ... +99.9 ±0.2 1.3 1 ... 10 22 x 27 / 17
9550414 PURA 14 +18 ... +99.9 ±0.2 1.3 1 ... 14 30 x 27 / 17
9550422 PURA 22 +18 ... +99.9 ±0.2 2 2 ... 22 54 x 27 / 17
9550430 PURA 30 +18 ... +99.9 ±0.2 2 2 ... 30 76 x 27 / 17

TW Series - water baths (Discontinued model)
Order No. Model Working temperature
range (°C)
Temperature stability
(°C)
Heating capacity (kW) Füllvolumen (l) Bath opening Comparison
9550102 TW2 +20 ... +99.9 ±0.2 1 1 ... 2 15 x 13 / 11
9550108 TW8 +20 ... +99.9 ±0.2 2 3 ... 8 23 x 27 /14
9550112 TW12 +20 ... +99.9 ±0.2 2 5 ... 14 35 x 27 / 14
9550120 TW20 +20 ... +99.9 ±0.2 2 8 ... 26 50 x 30 / 18

Contact

JULABO GmbH
Gerhard-Juchheim-Strasse 1
77960 Seelbach / Germany
Tel: +49 (0) 7823 / 510
info.de@julabo.com
www.julabo.com
Contact form