SE-Z SE-Z bridge mounted circulator

with extendable bridge for bath tanks up to 100 liters filling volume

JULABO bridge mounted circulator with extendable bridge made of stainless steel for any bath tanks. For internal and external temperature applications. The model offers high pump and heating capacities for temperature control of large baths up to 100 liters. Including a built-in cooling coil for counter-cooling with tap water.

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
SE-Z
Order No. 9 252 218
Working temperature range +20 ... +300 °C
Temperature stability +/-0.01 °C
Heating capacity 3 kW
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 0.4 ... 0.7 bar
Dimensions
(W × L × H)
32 x 17 x 41 cm
Arrange callback Accessory

Product Features

  • Integrated cooling coil for counter-cooling
  • Unique early warning system for low liquid level
  • VFD COMFORT DISPLAY
  • Keypad for setpoints, warning/safety values and menu functions
  • ATC3 3-Point-Calibration
  • Pt100 External sensor connection for measurement and control
  • SMART PUMP, electronically adjustable pump stages
  • Adjustable high temperature cut-out, visible via display
  • ICC (Intelligent Cascade Control), self-optimizing temperature control
  • Expandable bridge from 31 to 66 cm
Dimensions and volumes
Dimensions
(W × L × H)
32 x 17 x 41 cm
Weight 8 kg
Pump connections M16x1 male
Temperature values
Working temperature range +20 ... +300 °C
Temperature stability +/-0.01 °C
Setting the resolution of the temperature display 0.01 °C
Temperature display resolution 0.01 °C
Ambient temperature +5 ... +40.0 °C

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Heating capacity 3 kW
Pump capacity flow rate 22 ... 26 l/min
Pump capacity flow pressure 0.4 ... 0.7 bar
Maximum suction 0.2 ... 0.4 bar
Viscosity max. 50 cST
Power 14 A
Cooling
Cooling coil integrated
Other
Classification
according to DIN12876-1
Classification III (FL)
IP Code
according to IEC 60529
IP 21
Electronics
External pt100 sensor connection integrated
Integrated programmer 6x60 steps
Temperature control ICC
Absolute temperature calibration 3 Point Calibration
Temperature display VFD
Temperature setting Keypad
Available voltage versions
9252218.33 230V/50-60Hz (Schuko Plug - CEE 7/4 Plug Type F)
Included in delivery
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male)

Accessory for SE-Z

Contact expert

We would also be happy to send you our printed catalogs and brochures by post.


Request brochure

Benefits

  • Made in Germany
    JULABO. Quality.
    Highest standards of quality for a long product life.
  • Blatt wächst in einer Glühbirne
    Green technology.
    Development consistently applied environmentally friendly materials and technologies.
  • network
    Satisfied customers.
    11 subsidiaries and more than 100 partners worldwide guarantee fast and qualified JULABO support.
  • 100% geprüft
    100% Checked.
    100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.