with an enhanced pump performance and a temperature range up to +200 °C
Refrigerated circulators from the CORIO CP range are suitable for applications with a temperature range up to +200°C. The enhanced pump performance ensures they are suitable for easy temperature control tasks in combination with external applications.
Overview
Technical data
Accessory & Services
Downloads
Performance data depends on the mains voltage in the country of use. Please select:
Country of use | Mains voltage | Plug | JULABO voltage version code
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.
Pump capacity flow rate
8 ... 27 l/min
Pump capacity flow pressure
0.1 ... 0.7 bar
Viscosity max.
50 cSt
Power consumption
13 A
Bath
Bath tank
Stainless steel
Bath cover
integrated
Usable bath opening (W x L / D)
18 x 13 / 15 cm
Cooling
Cooling of compressor
1-stage Water
Cooling water pressure max.
6 bar
Recommended cooling water properties
to provide full cooling capacity according to catalog values
Cooling water temperature range
30 °C
Cooling water difference pressure
0.3 bar
Cooling water consumption
1.1 l/min
Other
Classification according to DIN12876-1
Classification III (FL)
Pump function
Pressure Pump
Pump type
Immersion Pump
Electronics
Interfaces
RS232 / USB
Temperature control
PID1
Absolute temperature calibration
3 Point Calibration
Temperature display
LED
Temperature setting
Keypad
Electronic Timer h:min
0 ... 999
Available voltage versions
9013727.02
115V/60Hz (Nema N5-20 Plug) (R449A)
9013727.04
200-230V/50-60Hz (UK Plug Type BS1363A) (R449A)
9013727.05
200-230V/50-60Hz (CH Plug Type SEV 1011) (R449A)
9013727.33
200-230V/50-60Hz (Schuko Plug - CEE 7/4 Plug Type F) (R449A)
9013727.33.chn
200-230V/50-60Hz (CN Plug) (R449A)
Included in delivery
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male)
Very bright display makes it easy to read even from a distance.
Switch on. And off you go.
Intelligent operating concept. Ready for operation with just a few quick and easy steps.
Timer. Integrated.
CORIO circulators include an integrated timer function. When the set time has elapsed, a signal sounds and the device switches off. Setting range: 0 ... 999 minutes.
Everything at the front.
All operating controls and safety functions are accessed easily and comfortably from the front.