FP51-SL Ultra-Low Refrigerated / Heating Circulator

low temperatures below -50 °C for internal and external applications

The Ultra-Low Refrigerated Circulators of the HighTech Series with HL or SL circulator feature powerful pressure and suction pumps. The instruments provide the entire variety of functions of the professional HighTech Series of circulators.

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
FP51-SL
Order No. 9352751.16
Working temperature range -51 ... +200 °C
Temperature stability ±0.05 °C
Heating capacity 3 kW
Cooling capacity
Medium: Ethanol
°C 20 0 -20 -40
kW 1 2 1.5 1 0.26
Refrigerant R507
Global Warming Potential 3985
Filling weight 830 g
Carbon dioxide equivalent 3.30755 t

1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.

Pump capacity flow pressure 22 ... 26 l/min
Circulation capacity pressure 5.8 ... 10.2 psi
Usable bath opening
(W x L / D)
7.1 x 4.7 / 7.9 in.
Filling volume 7.5 ... 12 l
Dimensions
(W × L × H)
18.1 x 21.7 x 35 in.
Arrange callback

Product Features

  • VFD COMFORT DISPLAY
  • LCD DIALOG DISPLAY backlit for convenient interactive operation
  • Keypad for setpoints, warning/safety values and menu functions
  • ICC (Intelligent Cascade Control), self-optimizing temperature control
  • TCF Temperature Control Features to optimize the control behavior
  • ATC3 3-Point-Calibration
  • Pt100 External sensor connection for measurement and control
  • SMART PUMP, electronically adjustable pump stages
  • Unique early warning system for low liquid level
  • Adjustable high temperature cut-out, visible via display
  • RS232/RS485 interface for online communication
  • Integrated programmer for 6 x 60 program steps
  • Connections for solenoid valve and HSP booster pump
  • Proportional cooling control
  • Active Cooling Control

Technical data for FP51-SL

Dimensions and volumes
Dimensions
(W × L × H)
18.1 x 21.7 x 35 in.
Filling volume 7.5 ... 12 l
Weight 198.4 lbs
Pump connections M16x1 male
Temperature values
Working temperature range -51 ... +200 °C
Temperature stability ±0.05 °C
Setting the resolution of the temperature display 0.01 °C
Temperature display resolution 0.01 °C
Ambient temperature +5 ... +40 °C

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Heating capacity 3 kW
Cooling capacity
Medium: Ethanol
°C 20 0 -20 -40
kW 1 2 1.5 1 0.26
Refrigerant R507
Global Warming Potential 3985
Filling weight 830 g
Carbon dioxide equivalent 3.30755 t

1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.

Pump capacity flow pressure 22 ... 26 l/min
Circulation capacity pressure 5.8 ... 10.2 psi
Maximum suction 2.9 ... 5.8 psi
Viscosity max. 70 cSt
Power consumption 16 A
Bath
Bath cover integrated
Usable bath opening
(W x L / D)
7.1 x 4.7 / 7.9 in.
Cooling
Cooling of compressor 1-stage Air
Other
Sound pressure level 63 dbA
Classification
according to DIN12876-1
Classification III (FL)
IP Code
according to IEC 60529
IP 21
Electronics
Interfaces Profibus optional
External pt100 sensor connection integrated
Integrated programmer 6x60 steps
Temperature control ICC
Absolute temperature calibration 3 Point Calibration
Temperature display VFD
Temperature setting Keypad
Available voltage versions
9352751.06 230V/3PPE/50Hz (Without Plug) (R507)
9352751.07 400V/3PNPE/50Hz (Plug 16A CEE) (R507)
9352751.S1.07 400V/3PNPE/50Hz (Plug 16A CEE) (R449A)
9352751.16 208V/3PPE/60Hz (Without Plug) (R507)
Included in delivery
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male)
Contact expert

Cool-down time

Medium: Ethanol

Heat-up time

Medium: Thermal

Pump capacity

Medium: Water

Accessory for FP51-SL

Downloads for FP51-SL

We would also be happy to send you our printed catalogs and brochures by post.

Request brochure

FP51-SL Benefits

For flammable bath fluid

Classification III (FL) according to DIN 12876-1

ATC3. Calibration.

‘Absolute Temperature Calibration’ for compensating a physically caused temperature difference, 3-point calibration.

Process. Under control.

Full control of the dynamic, access to all important control parameters for individual process optimization.

100 % Cooling capacity

‘Active Cooling Control’ for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures

Show all 17 benefits