FL4003
Order No. 9663040.16
Working temperature range -20 ... +40 °C
Temperature stability ±0.5 °C
Cooling capacity
Medium: Ethanol
°C 20 10 0 -10 -20
kW 1 4 3.4 2.4 1.5 0.6
Refrigerant R449A
Global Warming Potential 1397
Filling weight 1800 g
Carbon dioxide equivalent 2.5146 t

1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.

Pump capacity flow pressure 40 l/min
Circulation capacity pressure 7.3 ... 43.5 psi
Filling volume 24 ... 30 l
Dimensions
(W × L × H)
23.6 x 29.9 x 45.3 in.
Arrange callback

Product Features

  • Ergonomic design and easy operation
  • Splash-proof keypad
  • Large, bright LED display
  • Reliable Microprocessor PID temperature control
  • Precise PID temperature control
  • Powerful immersion pumps, suitable for continuous operation
  • Permissible temperature in return line +80°C
  • Easy filling from the top with hinged protective lid
  • Low liquid level protection with optical and audible alarm signal
  • Integrated stainless steel bath tanks
  • Front drain
  • No side vents, instruments can be placed right next to other equipment
  • RS232 interface for PC connection
  • IP class according to IEC 60529: 21
  • Alarm output, potential-free change-over contact (max. 30 VA)
  • Pressure Indicator

Technical data for FL4003

Dimensions and volumes
Dimensions
(W × L × H)
23.6 x 29.9 x 45.3 in.
Filling volume 24 ... 30 l
Weight 326.3 lbs
Pump connections G¾" male
Barbed fittings inner diameter ¾"
Temperature values
Working temperature range -20 ... +40 °C
Temperature stability ±0.5 °C
Setting the resolution of the temperature display 0.1 °C
Temperature display resolution 0.1 °C
Ambient temperature +5 ... +40 °C
Return flow temperature max. 80 °C

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Cooling capacity
Medium: Ethanol
°C 20 10 0 -10 -20
kW 1 4 3.4 2.4 1.5 0.6
Refrigerant R449A
Global Warming Potential 1397
Filling weight 1800 g
Carbon dioxide equivalent 2.5146 t

1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.

Pump capacity flow pressure 40 l/min
Circulation capacity pressure 7.3 ... 43.5 psi
Power consumption 11 A
Bath
Bath tank Stainless steel
Cooling
Cooling of compressor 1-stage Air
Other
Sound pressure level 67 dbA
Classification
according to DIN12876-1
Classification I (NFL)
IP Code
according to IEC 60529
IP 21
Pump type Immersion Pump
Electronics
Interfaces Alarm output / RS232 / Stakei
Temperature control PID1
Temperature display LED
Temperature setting Keypad
Available voltage versions
9663040.16 230V/3PPE/60Hz (Without Plug) (R449A)
9663040.07 400V/3PNPE/50Hz (Plug 16A CEE) (R452A)

Accessory for FL4003

Downloads for FL4003

We would also be happy to send you our printed catalogs and brochures by post.

Request brochure

FL4003 Benefits

100% Checked.

100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.

Green technology.

Development consistently applied environmentally friendly materials and technologies.

JULABO. Quality.

Highest standards of quality for a long product life.

Quick start.

Individual JULABO consultation and comprehensive manuals at your disposal.

Show all 8 benefits