The compact recirculating coolers in the F Series are economic models for routine applications in laboratories. The instruments cool in a temperature range of -10 or 0 °C to +40 °C and achieve a stability of ±0.5°C. The space saving design and lack of side vents allow flexible positioning even in small laboratories. Their high efficiency mean that the coolers in the F Series are an economic and environmentally friendly alternative to cooling with tap water. Low acquisition costs mean that they pay for themselves within a very short time.

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
F250
Order No. 9620025.02
Working temperature range -10 ... +40 °C
Temperature stability ±0.5 °C
Cooling capacity
Medium: Water Glycol
°C 20 15 10 5 0 -5 -10
kW 1 0.25 0.24 0.22 0.21 0.18 0.09 0.06
Refrigerant R134a
Global Warming Potential 1430
Filling weight 113 g
Carbon dioxide equivalent 0.16159 t

1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.

Pump capacity flow pressure 15 l/min
Circulation capacity pressure 5.1 psi
Filling volume 1.7 ... 2.6 l
Dimensions
(W × L × H)
9.4 x 15.7 x 20.5 in.
Arrange callback

Product Features

  • Environmentally friendly operation with low energy consumption
  • No side vents, instruments can be placed right next to other equipment
  • All wetted parts made of stainless steel or high grade plastic (except FC-T models)
  • Large, bright LED display
  • Compact design
  • Splash-proof keypad
  • Easy filling and Drain tap easily accessible

Technical data for F250

Dimensions and volumes
Dimensions
(W × L × H)
9.4 x 15.7 x 20.5 in.
Filling volume 1.7 ... 2.6 l
Weight 59.5 lbs
Pump connections M10x1 female
Barbed fittings inner diameter 8/10 mm
Temperature values
Working temperature range -10 ... +40 °C
Temperature stability ±0.5 °C
Setting the resolution of the temperature display 0.1 °C
Temperature display resolution 0.1 °C
Ambient temperature +5 ... +40 °C
Return flow temperature max. +80 °C

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Cooling capacity
Medium: Water Glycol
°C 20 15 10 5 0 -5 -10
kW 1 0.25 0.24 0.22 0.21 0.18 0.09 0.06
Refrigerant R134a
Global Warming Potential 1430
Filling weight 113 g
Carbon dioxide equivalent 0.16159 t

1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.

Pump capacity flow pressure 15 l/min
Circulation capacity pressure 5.1 psi
Power consumption 4 A
Bath
Bath tank Stainless steel
Cooling
Cooling of compressor 1-stage Air
Other
Sound pressure level 59 dbA
Classification
according to DIN12876-1
Classification I (NFL)
IP Code
according to IEC 60529
IP 20
Pump type Centrifugal Pump
Electronics
Temperature control PID1
Temperature display LED
Temperature setting Keypad
Available voltage versions
9620025.01 100V/50-60Hz (Nema N5-15 Plug) (R134a)
9620025.02 115V/60Hz (Nema N5-15 Plug) (R134a)
9620025.03 230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F) (R134a)
9620025.04 230V/50Hz (UK Plug Type BS1363A) (R134a)
9620025.05 230V/50Hz (CH Plug Type SEV 1011) (R134a)
9620025.12 200V/50-60Hz (Schuko Plug - CEE 7/4 Plug Type F) (R134a)
9620025.13 230V/60Hz (Schuko Plug - CEE 7/4 Plug Type F) (R134a)
Included in delivery
2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female)

Accessory for F250

Downloads for F250

We would also be happy to send you our printed catalogs and brochures by post.

Request brochure

F250 Benefits

100% Checked.

100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.

Green technology.

Development consistently applied environmentally friendly materials and technologies.

JULABO. Quality.

Highest standards of quality for a long product life.

Quick start.

Individual JULABO consultation and comprehensive manuals at your disposal.

Show all 7 benefits