Working temperature range -40 ... +30 °C
Cooling capacity
Medium: Ethanol
°C 20 10 0 -20 -40
kW 1 0.45 0.36 0.3 0.14 0.03
Refrigerant R449A
Global Warming Potential 1397
Filling weight 112 g
Carbon dioxide equivalent 0.156464 t

1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.

Dimensions
(W × L × H)
7.9 x 11.8 x 16.9 in.
Arrange callback

Product Features

  • Rapid cooling of liquids down to low temperatures
  • Counter-cooling of liquids in combination with heating circulators
  • Preventing the use of precious tap water for cooling
  • Compact design, small footprint
  • Ease of operation
  • Dry ice substitution

Technical data for FT400

Dimensions and volumes
Dimensions
(W × L × H)
7.9 x 11.8 x 16.9 in.
Weight 52.9 lbs
Temperature values
Working temperature range -40 ... +30 °C
Ambient temperature +5 ... +35 °C

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Cooling capacity
Medium: Ethanol
°C 20 10 0 -20 -40
kW 1 0.45 0.36 0.3 0.14 0.03
Refrigerant R449A
Global Warming Potential 1397
Filling weight 112 g
Carbon dioxide equivalent 0.156464 t

1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.

Power consumption 4 A
Cooling
Cooling of compressor 1-stage Air
Other
Sound pressure level 61 dbA
IP Code
according to IEC 60529
IP 21
Immersion cooler
Immersion probe type inflexible
Dimensions immersion probe cylindrical
(L x Ø)
4.7 x 2 in.
Available voltage versions
9650840.02 115V/60Hz (Nema N5-15 Plug) (R449A)
9650840.03 230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F) (R452A)
9650840.04 230V/50Hz (UK Plug Type BS1363A) (R452A)
9650840.05 230V/50Hz (CH Plug Type SEV 1011) (R452A)

Accessory for FT400

Downloads for FT400

We would also be happy to send you our printed catalogs and brochures by post.

Request brochure

FT400 Benefits

100% Checked.

100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.

Green technology.

Development consistently applied environmentally friendly materials and technologies.

JULABO. Quality.

Highest standards of quality for a long product life.

Quick start.

Individual JULABO consultation and comprehensive manuals at your disposal.

Show all 6 benefits