MAGIO MS-900F Refrigerated / Heating circulator
with extremely powerful pressure/suction pump and intuitive touch display
As with all circulators from the MAGIO range, the refrigerated circulators stand out thanks to their premium quality, high performance and intuitive operation. The devices offer extra strong pressure and suction pumps, thus fulfilling the highest demands for temperature control of external applications. Whether in basic research, material testing or technical systems – the MAGIO refrigerated circulators offer high-tech solutions for high customer requirements.
Request a quoteHigh resolution TFT touch display
The modern TFT touch display gives you all the important information at a glance. Three large, predefined main screens clearly display data and graphics with various application priorities. Menu navigation is self-explanatory, arranged by relevance to daily operations and easy to operate with the touch of a finger. The in-built help function provides detailed support in case of additional questions.
Order No. | 9 032 706.02 | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +200.0 °C | |||||||||||||||||
Temperature stability | +/-0.01 °C | |||||||||||||||||
Heating capacity | 1 kW | |||||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||||
|
||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | |||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | |||||||||||||||||
Usable bath opening (W x L / D) |
10.2 x 13.8 / 7.9 in. | |||||||||||||||||
Filling volume | 21 ... 30 l | |||||||||||||||||
Dimensions (W × L × H) |
15.4 x 24.4 x 29.5 in. |
Order No. | 9 032 706.05 | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +200.0 °C | |||||||||||||||||
Temperature stability | +/-0.01 °C | |||||||||||||||||
Heating capacity | 1.6 kW | |||||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||||
|
||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | |||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | |||||||||||||||||
Usable bath opening (W x L / D) |
10.2 x 13.8 / 7.9 in. | |||||||||||||||||
Filling volume | 21 ... 30 l | |||||||||||||||||
Dimensions (W × L × H) |
15.4 x 24.4 x 29.5 in. |
Order No. | 9 032 706.05 | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +200.0 °C | |||||||||||||||||
Temperature stability | +/-0.01 °C | |||||||||||||||||
Heating capacity | 1.6 kW | |||||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||||
|
||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | |||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | |||||||||||||||||
Usable bath opening (W x L / D) |
10.2 x 13.8 / 7.9 in. | |||||||||||||||||
Filling volume | 21 ... 30 l | |||||||||||||||||
Dimensions (W × L × H) |
15.4 x 24.4 x 29.5 in. |
Order No. | 9 032 706.05 | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +200.0 °C | |||||||||||||||||
Temperature stability | +/-0.01 °C | |||||||||||||||||
Heating capacity | 2 kW | |||||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||||
|
||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | |||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | |||||||||||||||||
Usable bath opening (W x L / D) |
10.2 x 13.8 / 7.9 in. | |||||||||||||||||
Filling volume | 21 ... 30 l | |||||||||||||||||
Dimensions (W × L × H) |
15.4 x 24.4 x 29.5 in. |
Order No. | 9 032 706.05 | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +200.0 °C | |||||||||||||||||
Temperature stability | +/-0.01 °C | |||||||||||||||||
Heating capacity | 2 kW | |||||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||||
|
||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | |||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | |||||||||||||||||
Usable bath opening (W x L / D) |
10.2 x 13.8 / 7.9 in. | |||||||||||||||||
Filling volume | 21 ... 30 l | |||||||||||||||||
Dimensions (W × L × H) |
15.4 x 24.4 x 29.5 in. |
Order No. | 9 032 706.04 | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +200.0 °C | |||||||||||||||||
Temperature stability | +/-0.01 °C | |||||||||||||||||
Heating capacity | 1.6 kW | |||||||||||||||||
Cooling capacity |
|
|
||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||||
|
||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | |||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | |||||||||||||||||
Usable bath opening (W x L / D) |
10.2 x 13.8 / 7.9 in. | |||||||||||||||||
Filling volume | 21 ... 30 l | |||||||||||||||||
Dimensions (W × L × H) |
15.4 x 24.4 x 29.5 in. |
Order No. | 9 032 706.04 | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +200.0 °C | |||||||||||||||||
Temperature stability | +/-0.01 °C | |||||||||||||||||
Heating capacity | 1.6 kW | |||||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||||
|
||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | |||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | |||||||||||||||||
Usable bath opening (W x L / D) |
10.2 x 13.8 / 7.9 in. | |||||||||||||||||
Filling volume | 21 ... 30 l | |||||||||||||||||
Dimensions (W × L × H) |
15.4 x 24.4 x 29.5 in. |
Order No. | 9 032 706.04 | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +200.0 °C | |||||||||||||||||
Temperature stability | +/-0.01 °C | |||||||||||||||||
Heating capacity | 2 kW | |||||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||||
|
||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | |||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | |||||||||||||||||
Usable bath opening (W x L / D) |
10.2 x 13.8 / 7.9 in. | |||||||||||||||||
Filling volume | 21 ... 30 l | |||||||||||||||||
Dimensions (W × L × H) |
15.4 x 24.4 x 29.5 in. |
Order No. | 9 032 706.04 | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +200.0 °C | |||||||||||||||||
Temperature stability | +/-0.01 °C | |||||||||||||||||
Heating capacity | 2 kW | |||||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||||
|
||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | |||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | |||||||||||||||||
Usable bath opening (W x L / D) |
10.2 x 13.8 / 7.9 in. | |||||||||||||||||
Filling volume | 21 ... 30 l | |||||||||||||||||
Dimensions (W × L × H) |
15.4 x 24.4 x 29.5 in. |
Order No. | 9 032 706.33 | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +200.0 °C | |||||||||||||||||
Temperature stability | +/-0.01 °C | |||||||||||||||||
Heating capacity | 1.6 kW | |||||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||||
|
||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | |||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | |||||||||||||||||
Usable bath opening (W x L / D) |
10.2 x 13.8 / 7.9 in. | |||||||||||||||||
Filling volume | 21 ... 30 l | |||||||||||||||||
Dimensions (W × L × H) |
15.4 x 24.4 x 29.5 in. |
Order No. | 9 032 706.33 | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +200.0 °C | |||||||||||||||||
Temperature stability | +/-0.01 °C | |||||||||||||||||
Heating capacity | 1.6 kW | |||||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||||
|
||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | |||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | |||||||||||||||||
Usable bath opening (W x L / D) |
10.2 x 13.8 / 7.9 in. | |||||||||||||||||
Filling volume | 21 ... 30 l | |||||||||||||||||
Dimensions (W × L × H) |
15.4 x 24.4 x 29.5 in. |
Order No. | 9 032 706.33 | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +200.0 °C | |||||||||||||||||||
Temperature stability | +/-0.01 °C | |||||||||||||||||||
Heating capacity | 2 kW | |||||||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||||||
|
||||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | |||||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | |||||||||||||||||||
Usable bath opening (W x L / D) |
10.2 x 13.8 / 7.9 in. | |||||||||||||||||||
Filling volume | 21 ... 30 l | |||||||||||||||||||
Dimensions (W × L × H) |
15.4 x 24.4 x 29.5 in. |
Order No. | 9 032 706.33 | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +200.0 °C | |||||||||||||||||
Temperature stability | +/-0.01 °C | |||||||||||||||||
Heating capacity | 2 kW | |||||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||||
|
||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | |||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | |||||||||||||||||
Usable bath opening (W x L / D) |
10.2 x 13.8 / 7.9 in. | |||||||||||||||||
Filling volume | 21 ... 30 l | |||||||||||||||||
Dimensions (W × L × H) |
15.4 x 24.4 x 29.5 in. |
Order No. | 9 032 706.33.chn | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +200.0 °C | |||||||||||||||||
Temperature stability | +/-0.01 °C | |||||||||||||||||
Heating capacity | 1.6 kW | |||||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||||
|
||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | |||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | |||||||||||||||||
Usable bath opening (W x L / D) |
10.2 x 13.8 / 7.9 in. | |||||||||||||||||
Filling volume | 21 ... 30 l | |||||||||||||||||
Dimensions (W × L × H) |
15.4 x 24.4 x 29.5 in. |
Order No. | 9 032 706.33.chn | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +200.0 °C | |||||||||||||||||
Temperature stability | +/-0.01 °C | |||||||||||||||||
Heating capacity | 1.6 kW | |||||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||||
|
||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | |||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | |||||||||||||||||
Usable bath opening (W x L / D) |
10.2 x 13.8 / 7.9 in. | |||||||||||||||||
Filling volume | 21 ... 30 l | |||||||||||||||||
Dimensions (W × L × H) |
15.4 x 24.4 x 29.5 in. |
Order No. | 9 032 706.33.chn | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +200.0 °C | |||||||||||||||||
Temperature stability | +/-0.01 °C | |||||||||||||||||
Heating capacity | 2 kW | |||||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||||
|
||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | |||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | |||||||||||||||||
Usable bath opening (W x L / D) |
10.2 x 13.8 / 7.9 in. | |||||||||||||||||
Filling volume | 21 ... 30 l | |||||||||||||||||
Dimensions (W × L × H) |
15.4 x 24.4 x 29.5 in. |
Order No. | 9 032 706.33.chn | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -38 ... +200.0 °C | |||||||||||||||||
Temperature stability | +/-0.01 °C | |||||||||||||||||
Heating capacity | 2 kW | |||||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||||
|
||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | |||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | |||||||||||||||||
Usable bath opening (W x L / D) |
10.2 x 13.8 / 7.9 in. | |||||||||||||||||
Filling volume | 21 ... 30 l | |||||||||||||||||
Dimensions (W × L × H) |
15.4 x 24.4 x 29.5 in. |
Product Features
- Ideal for demanding external applications
- Simple control of complex applications
- Continuously adjustable, extremely powerful pressure / suction pump
- Flow rate 16 ... 31 l / min, pressure 0.24 ... 0.92 bar, suction 0.03 ... 0.4 bar
- Large, high-resolution TFT touch display with multilingual user interface
- Parts being in contact with the medium made of stainless steel
- Integrated programmer
- Integrated external Pt100 connection
- USB connection
- RS232 interface for online communication
- Ethernet
- analog interfaces (accessory)
- Class III (FL) according to DIN 12876-1
- Modbus
- Profibus DP (Accessory)
- RS232/RS485 interface for online communication
Dimensions (W × L × H) |
15.4 x 24.4 x 29.5 in. |
---|---|
Filling volume | 21 ... 30 l |
Weight | 121 lbs |
Pump connections | M16x1 male |
Pump connections | M16x1 male |
Working temperature range | -38 ... +200.0 °C |
---|---|
Temperature stability | +/-0.01 °C |
Setting the resolution of the temperature display | 0.01 °C |
Temperature display resolution | 0.01 °C |
Ambient temperature | +10.0 ... +40.0 °C |
Heating capacity | 1 kW | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||||
|
|||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | ||||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | ||||||||||||||||||
Maximum suction | -0.4 ... -5.8 psi | ||||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||||
Filling volume | 220 g | ||||||||||||||||||
Carbon dioxide equivalent | 0.307 t | ||||||||||||||||||
Power | 16 A |
Heating capacity | 1.6 kW | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||||
|
|||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | ||||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | ||||||||||||||||||
Maximum suction | -0.4 ... -5.8 psi | ||||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||||
Filling volume | 220 g | ||||||||||||||||||
Carbon dioxide equivalent | 0.307 t | ||||||||||||||||||
Power | 10 A |
Heating capacity | 1.6 kW | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||||
|
|||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | ||||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | ||||||||||||||||||
Maximum suction | -0.4 ... -5.8 psi | ||||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||||
Filling volume | 220 g | ||||||||||||||||||
Carbon dioxide equivalent | 0.307 t | ||||||||||||||||||
Power | 10 A |
Heating capacity | 2 kW | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||||
|
|||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | ||||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | ||||||||||||||||||
Maximum suction | -0.4 ... -5.8 psi | ||||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||||
Filling volume | 220 g | ||||||||||||||||||
Carbon dioxide equivalent | 0.307 t | ||||||||||||||||||
Power | 10 A |
Heating capacity | 2 kW | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||||
|
|||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | ||||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | ||||||||||||||||||
Maximum suction | -0.4 ... -5.8 psi | ||||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||||
Filling volume | 220 g | ||||||||||||||||||
Carbon dioxide equivalent | 0.307 t | ||||||||||||||||||
Power | 10 A |
Heating capacity | 1.6 kW | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity |
|
|
|||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||||
|
|||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | ||||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | ||||||||||||||||||
Maximum suction | -0.4 ... -5.8 psi | ||||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||||
Filling volume | 220 g | ||||||||||||||||||
Carbon dioxide equivalent | 0.307 t | ||||||||||||||||||
Power | 12 A |
Heating capacity | 1.6 kW | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||||
|
|||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | ||||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | ||||||||||||||||||
Maximum suction | -0.4 ... -5.8 psi | ||||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||||
Filling volume | 220 g | ||||||||||||||||||
Carbon dioxide equivalent | 0.307 t | ||||||||||||||||||
Power | 12 A |
Heating capacity | 2 kW | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||||
|
|||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | ||||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | ||||||||||||||||||
Maximum suction | -0.4 ... -5.8 psi | ||||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||||
Filling volume | 220 g | ||||||||||||||||||
Carbon dioxide equivalent | 0.307 t | ||||||||||||||||||
Power | 13 A |
Heating capacity | 2 kW | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||||
|
|||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | ||||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | ||||||||||||||||||
Maximum suction | -0.4 ... -5.8 psi | ||||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||||
Filling volume | 220 g | ||||||||||||||||||
Carbon dioxide equivalent | 0.307 t | ||||||||||||||||||
Power | 13 A |
Heating capacity | 1.6 kW | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||||
|
|||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | ||||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | ||||||||||||||||||
Maximum suction | -0.4 ... -5.8 psi | ||||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||||
Filling volume | 220 g | ||||||||||||||||||
Carbon dioxide equivalent | 0.307 t | ||||||||||||||||||
Power | 15 A |
Heating capacity | 1.6 kW | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||||
|
|||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | ||||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | ||||||||||||||||||
Maximum suction | -0.4 ... -5.8 psi | ||||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||||
Filling volume | 220 g | ||||||||||||||||||
Carbon dioxide equivalent | 0.307 t | ||||||||||||||||||
Power | 15 A |
Heating capacity | 2 kW | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||||||
|
|||||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | ||||||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | ||||||||||||||||||||
Maximum suction | -0.4 ... -5.8 psi | ||||||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||||||
Filling volume | 220 g | ||||||||||||||||||||
Carbon dioxide equivalent | 0.307 t | ||||||||||||||||||||
Power | 16 A |
Heating capacity | 2 kW | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||||
|
|||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | ||||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | ||||||||||||||||||
Maximum suction | -0.4 ... -5.8 psi | ||||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||||
Filling volume | 220 g | ||||||||||||||||||
Carbon dioxide equivalent | 0.307 t | ||||||||||||||||||
Power | 16 A |
Heating capacity | 1.6 kW | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||||
|
|||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | ||||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | ||||||||||||||||||
Maximum suction | -0.4 ... -5.8 psi | ||||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||||
Filling volume | 220 g | ||||||||||||||||||
Carbon dioxide equivalent | 0.307 t | ||||||||||||||||||
Power | 13 A |
Heating capacity | 1.6 kW | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||||
|
|||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | ||||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | ||||||||||||||||||
Maximum suction | -0.4 ... -5.8 psi | ||||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||||
Filling volume | 220 g | ||||||||||||||||||
Carbon dioxide equivalent | 0.307 t | ||||||||||||||||||
Power | 13 A |
Heating capacity | 2 kW | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||||
|
|||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | ||||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | ||||||||||||||||||
Maximum suction | -0.4 ... -5.8 psi | ||||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||||
Filling volume | 220 g | ||||||||||||||||||
Carbon dioxide equivalent | 0.307 t | ||||||||||||||||||
Power | 14 A |
Heating capacity | 2 kW | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||||
|
|||||||||||||||||||
Pump capacity flow rate | 16 ... 31 l/min | ||||||||||||||||||
Pump capacity flow pressure | 3.5 ... 13.3 psi | ||||||||||||||||||
Maximum suction | -0.4 ... -5.8 psi | ||||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||||||
Filling volume | 220 g | ||||||||||||||||||
Carbon dioxide equivalent | 0.307 t | ||||||||||||||||||
Power | 14 A |
Bath tank | Stainless steel |
---|---|
Bath cover | integrated |
Usable bath opening (W x L / D) |
10.2 x 13.8 / 7.9 in. |
Cooling of compressor | 1-stage Air |
---|
Classification according to DIN12876-1 |
Classification III (FL) |
---|---|
IP Code according to IEC 60529 |
IP 21 |
Pump function | Pressure Suction Pump |
Pump type | Immersion Pump |
External pt100 sensor connection | integrated |
---|---|
Integrated programmer | 8x60 steps |
Temperature control | ICC |
Absolute temperature calibration | 3 Point Calibration |
Temperature displayTemperature display | 7" TFT Touchscreen |
Temperature settingTemperature setting | Touchscreen |
Electronic Timer hr:min |
00:00 ... 00:00 |
115V/60Hz Nema N5-20 Plug | 9032706.02 |
---|---|
200-230V/50-60Hz CH Plug Type SEV 1011 | 9032706.05 |
200-230V/50-60Hz UK Plug Type BS1363A | 9032706.04 |
200-230V/50-60Hz Schuko Plug - CEE 7/4 Plug Type F | 9032706.33 |
200-230V/50-60Hz CN Plug | 9032706.33.chn |
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male) |
Accessory for MAGIO MS-900F
Benefits
-
100% Checked.
100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory. -
Green technology.
Development consistently applied environmentally friendly materials and technologies. -
Intelligent temperature control.
Intelligent cascade control - automatic and self-optimizing adaptation of the PID control parameters with external stability of +/- 0.05 °C. -
JULABO. Quality.
Highest standards of quality for a long product life.