CP-BC12
Order No. 9 013 512
Working temperature range +20 ... +200 °C
Temperature stability ±0.02 °C
Heating capacity 1 kW
Pump capacity flow pressure 8 ... 27 l/min
Circulation capacity pressure 1.5 ... 10.2 psi
Usable bath opening
(W x L / D)
8.7 x 5.9 / 7.9 in.
Filling volume 8.5 ... 12 l
Dimensions
(W × L × H)
13 x 19.3 x 18.5 in.
Arrange callback

Product Features

  • Models for internal and external applications
  • Bright, white, easy to read display
  • Very quiet
  • easy switching between internal and external circulation
  • powerful and infinitely adjustable pressure pump
  • USB connection
  • RS232 interface for online communication
  • High-quality bath tanks made of stainless steel with bath lid and drain tap
  • Integrated pump connection M16×1
  • Integrated cooling coil for counter-cooling
  • Easy operation

Technical data for CORIO CP-BC12

Dimensions and volumes
Dimensions
(W × L × H)
13 x 19.3 x 18.5 in.
Filling volume 8.5 ... 12 l
Weight 26.5 lbs
Pump connections M16x1 male
Barbed fittings inner diameter 8/12 mm
Temperature values
Working temperature range +20 ... +200 °C
Temperature stability ±0.02 °C
Setting the resolution of the temperature display 0.1 °C
Temperature display resolution 0.01 ... 0.1 °C
Ambient temperature 1 +5 ... +40 °C

1 For applications near or below ambient temperature: use a cooling coil or JULABO immersion cooler.

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Heating capacity 1 kW
Pump capacity flow pressure 8 ... 27 l/min
Circulation capacity pressure 1.5 ... 10.2 psi
Viscosity max. 50 cSt
Power consumption 10 A
Bath
Bath tank Stainless steel
Bath cover integrated
Usable bath opening
(W x L / D)
8.7 x 5.9 / 7.9 in.
Other
Classification
according to DIN12876-1
Classification III (FL)
Pump function Pressure Pump
Pump type Immersion Pump
Electronics
Interfaces RS232 / USB
Temperature control PID1
Absolute temperature calibration 3 Point Calibration
Temperature display LED
Temperature setting Keypad
Electronic Timer
h:min
0 ... 999
Available voltage versions
9013512.33 200-230V/50-60Hz (Schuko Plug - CEE 7/4 Plug Type F)
9013512.33.chn 200-230V/50-60Hz (CN Plug)
9013512.04 200-230V/50-60Hz (UK Plug Type BS1363A)
9013512.05 200-230V/50-60Hz (CH Plug Type SEV 1011)
9013512.22 100-115V/50-60Hz (Nema N5-15 Plug)
Included in delivery
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male)
Contact expert

Pump capacity

Medium: Water

Accessory for CORIO CP-BC12

Downloads for CORIO CP-BC12

We would also be happy to send you our printed catalogs and brochures by post.

Request brochure

CORIO CP-BC12 Benefits

Brilliant.

Very bright display makes it easy to read even from a distance.

Switch on. And off you go.

Intelligent operating concept. Ready for operation with just a few quick and easy steps.

Timer. Integrated.

CORIO circulators include an integrated timer function. When the set time has elapsed, a signal sounds and the device switches off. Setting range: 0 ... 999 minutes.

Everything at the front.

All operating controls and safety functions are accessed easily and comfortably from the front.