PRESTO W40 Process system

Compact process systems down to -45 °C

JULABO's water-cooled PRESTO W40 process system combines high performance and a very compact design with all the advantages of the PRESTO series for a working temperature range from -40 °C to +250 °C.

The highly dynamic temperature control systems PRESTO are designed for high-precision temperature control for a wide range of applications such as reactor vessels or material stress tests. Moreover, by using efficient components, the process systems can compensate exothermic and endothermic reactions exceptionally fast. Permanent internal monitoring and self-lubricating pumps ensure a long life-time. In addition, numerous interfaces offer many remote control possibilities across networks or for integration into higher-level control systems.

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
W40
Order No. see refrigerant variants
Working temperature range -40 ... +250 °C
Temperature stability ±0.01 ... ±0.05 °C
Heating capacity 2.7 kW
Cooling capacity
Refrigerant variant
Order No. 9421401.33
Cooling capacity 1 Medium: Ethanol
°C 20 0 -10 -20 -30 -40
kW 1 1.2 1 0.8 0.55 0.3 0.07
Cooling capacity 2 Medium: Ethanol
°C 20 0 -10 -20 -30
kW 1 1.2 1 0.8 0.4 0.12
Refrigerant R449A
Global Warming Potential 1397
Filling weight 380 g
Carbon dioxide equivalent 0.53086 t
Refrigerant variant
Order No. 9421401.33
Medium: Ethanol
°C 20 0 -10 -20 -30 -40
kW 1 1.2 1 0.8 0.55 0.3 0.07
Refrigerant R507
Global Warming Potential 3985
Filling weight 430 g
Carbon dioxide equivalent 1.71355 t

1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.
Cooling capacity 1 = capacity at minimum pump level, cooling capacity 2 = capacity at maximum pump level

Pump capacity flow pressure 0 ... 40 l/min
Circulation capacity pressure 0.1 ... 1.7 bar
Dimensions
(W × L × H)
33 x 59 x 67 cm
Arrange callback

Product Features

  • Heating capacity up to 2.7 kW
  • Temperature stability ±0.01 °C ... ±0.05 °C
  • Alarm output
  • Built-in 5.7’’ industrial color touchscreen
  • External Pt100 sensor connection
  • Second external Pt100 sensor connection (accessory)
  • Connections for USB, Ethernet, RS232, and Alarm output
  • Analog connections, RS485, Profibus DP (accessory)
  • Pump pressure up to 1.7 bar, max. flow rate 40 l/min
  • RS232
  • RS485 (Accessory)
  • Profibus DP (Accessory)
  • Cooling capacity up to 1.2 kW

Technical data for PRESTO W40

Dimensions and volumes
Dimensions
(W × L × H)
33 x 59 x 67 cm
Internal usable expansion volume 2.7 l
Minimal process volume 3.5 l
Active heat exchanger volume 1.7 l
Weight 78 kg
Pump connections M24x1.5 male
Cooling Water Connection G¾ in
Temperature values
Working temperature range -40 ... +250 °C
Temperature stability ±0.01 ... ±0.05 °C
Setting the resolution of the temperature display 0.01 °C
Temperature display resolution 0.01 °C
Ambient temperature +5 ... +40 °C

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Heating capacity 2.7 kW
Cooling capacity
Refrigerant variant
Order No. 9421401.33
Cooling capacity 1 Medium: Ethanol
°C 20 0 -10 -20 -30 -40
kW 1 1.2 1 0.8 0.55 0.3 0.07
Cooling capacity 2 Medium: Ethanol
°C 20 0 -10 -20 -30
kW 1 1.2 1 0.8 0.4 0.12
Refrigerant R449A
Global Warming Potential 1397
Filling weight 380 g
Carbon dioxide equivalent 0.53086 t
Refrigerant variant
Order No. 9421401.33
Medium: Ethanol
°C 20 0 -10 -20 -30 -40
kW 1 1.2 1 0.8 0.55 0.3 0.07
Refrigerant R507
Global Warming Potential 3985
Filling weight 430 g
Carbon dioxide equivalent 1.71355 t

1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.
Cooling capacity 1 = capacity at minimum pump level, cooling capacity 2 = capacity at maximum pump level

Pump capacity flow pressure 0 ... 40 l/min
Circulation capacity pressure 0.1 ... 1.7 bar
Viscosity max. 50 cSt
Power consumption 16 A
Cooling
Cooling of compressor 1-stage Water
Cooling water pressure max. 6 bar

Recommended cooling water properties
to provide full cooling capacity according to catalog values
Cooling water temperature range 35 °C
Cooling water difference pressure 0.5 bar
Cooling water consumption 2 1 l/min

2 Cooling water consumption may vary outside recommended cooling water properties.

Other
Sound pressure level 53 dbA
Classification
according to DIN12876-1
Classification III (FL)
IP Code
according to IEC 60529
IP 21
Pump type Centrifugal Pump (Magnetically coupled)
Electronics
Interfaces Alarm output / Ethernet / Modbus / Profibus optional / REG/EPROG optional / RS232 / RS485 optional / SD memory card / Standby-Input optional / USB
External pt100 sensor connection integrated
2nd external Pt100 sensor connection accessory
Integrated programmer 8x60 steps
Temperature control ICC
Absolute temperature calibration 3 Point Calibration
Temperature display 5.7" TFT Touchscreen
Temperature setting Touchscreen
Available voltage versions
9421401.33 200-230V/50-60Hz (Schuko Plug - CEE 7/4 Plug Type F) (R449A)
9421401.04 230V/50-60Hz (UK Plug Type BS1363A) (R449A)
9421401.05 230V/50-60Hz (CH Plug Type SEV 1011) (R449A)
9421401.14 208V/60Hz (Nema N6-20 Plug) (R449A)
Contact expert

Cool-down time

Medium: Thermal HL

Heat-up time

Medium: Thermal HL

Pump capacity

Accessory for PRESTO W40

Downloads for PRESTO W40

We would also be happy to send you our printed catalogs and brochures by post.

Request brochure

PRESTO W40 Benefits

Convenience for several users

Administrator level for customizing instrument settings, user levels with limited permissions for fast and safe defined access, password protection, all levels adjustable

100 % Cooling capacity

‘Active Cooling Control’ for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures

Intelligent temperature control.

Intelligent cascade control - automatic and self-optimizing adaptation of the PID control parameters with external stability of +/- 0.05 °C.

Full control

‘Temperature Control Features’, for individual optimization, access to all important control parameters, additional settings for band limit, limits, co-speedfactor etc.

Show all 21 benefits