Refrigerated - Heating Circulators

F26-ED Refrigerated/Heating Circulator

The Base for routine laboratory applications.

JULABO Refrigerated & Heating Circulators for heating and cooling are suitable for external temperature tasks and for temperature applications directly in the bath. A model from three different series’ with different capacities can be selected. Powerful circulating pump systems and high heating and cooling capacities guarantee short heat-up and cool-down times. The inevitable dust accumulation that occurs in refrigeration systems is solved by means of an easily removed venting grill, which allows for easy cleaning. Depending on the model, the units are equipped with handles or castors for an easy transportation. All models have a drain screw on the front allowing the fluid to be drained easily. The compact assembly of each unit enables a space to be saved in the laboratory. 

Your advantages

  • Bright LED temperature display, resolution 0.1 °C
  • Keypad for setpoint, switches automatically to the actual value
  • PID1 temperature control
  • Adjustable high temperature cut-out / dry-running protection

Technical Data

Order No. 9116626
Model series Economy
Category Refrigerated - Heating Circulators
Working temperature range (°C) -28 ... 100
Temperature control PID
Temperature stability (°C) ±0.03
Setting / display resolution 0.1 °C
Temperature Display LED
Heating capacity (kW) 1
Cooling capacity (Medium Ethanol)
20°C 0.26 kW
0°C 0.2 kW
-20°C 0.06 kW
Pump capacity flow rate (l/min) 15
Pump capacity flow pressure (psi) 5.1
Bath opening / bath depth (W x L / D inch) 4.7 x 5.5 / 5.5
Pump connections M10x1
Barbed fittings diameter (inner dia. / mm) 8 / 10
Filling volume (liters) 4.5
Refrigerant R134a
Ambient temperature 5...40 °C
Dimensions W x L x H (inch) 16.5 x 16.5 x 16.5
Weight (LBS) 66
Classification according to DIN12876-1 Classification I (NFL) according to DIN 12876-1
Included with each unit 2 barbed fittings 8 and 10mm inner dia. (pump connections M10x1 male)
Cooling of compressor Air
Power requirement V / Hz / A 230/50/12 Additional voltage versions available
Alarm signal optical

Characteristics

Easy to read
Large LED temperature display for actual value and setpoint (resolution 0.1 °C)
Clear and simple
3-key operation for easy setpoint adjustment
Precise
PID Temperature control with set control parameters, temperature stability ±0.02...±0.2 °C
Protective functions
Adjustable high temperature cut-off or dry-running protection
Only for non-flammable bath fluids
Classification I (NFL) according to DIN 12876-1
Consistent cooling capacity
Easily removable venting grid for quick and easy cleaning
100 % Cooling capacity
Active Cooling Control’ for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures

Other characteristics

Removable venting grid for quick and easy cleaning, to maintain cooling performance.

Technical changes without prior notification.
Images may deviate from the original.

We would be pleased to submit a non-binding offer for the selected product or answer all pertinent questions.

> click here for quotation request F26-ED

Order catalog

Order our new Catalog.

Contact

JULABO USA Inc.
884 Marcon Boulevard
Allentown, PA 18109
Phone: 610-231-0250
Phone: 800-458-5226
(Toll-Free)
info@julabo.com
www.julabo.com

Contact form

Accessories

Related models

F12-ED F25-ED F25-EH F34-ED

Available voltage versions

Model: F26-ED
Order No.: 9116626
Refrigerated - Heating Circulators

230V / 50 Hz 115V / 60 Hz 100V / 50-60 Hz