Print

MA-12 Heating Circulator

Middle class for a broad range of applications +20°C...200°C

Heating Circulator for internal and external temperature applications.
 
JULABO circulators with stainless steel bath tanks are suitable for both internal and external temperature control. They are designed primarily for external temperature control. They have elevated performance for controlling the temperature of large or open systems. Smaller objects may be inserted directly into the circulator's bath at the same time. Models of the TopTech and HighTech series are available with a variety of bath sizes and functional characteristics. Bath covers and a variety of bath inserts for laboratory glassware are available as accessories.

Your advantages

  • MULTI-DISPLAY (LED) for actual and setpoint values, warning/safety functions and pump stage
  • Keypad for setpoints, warning/safety values and menu functions
  • PID2 temperature control with drift compensation
  • ATC3 3-Point-Calibration
  • Early warning system for low liquid level (DBGM 203 06 059.8)
  • Adjustable high temperature cut-out, visible via display
  • RS232 interface for online communication
  • SMART PUMP, electronically adjustable pump stages

Technical Data

Order No. 9153512
Model series TopTech
Category Heating Circulators
Working temperature range (°C) +20 ... +200
Temperature stability (°C) ±0.01
Setting / display resolution 0.01 (-9.99...99.99) / 0.1 °C
Temperature Display VFD
Heating capacity (kW) 1
Pump capacity flow rate (l/min) 11-16
Pump capacity flow pressure (psi) 3.3-6.5
Bath opening / bath depth (W x L / D inch) 8.7 x 5.9 x 7.9
Pump connections M10x1
Barbed fittings diameter (inner dia. / mm) 8 / 10
Filling volume (liters) 12
Digital interfaces RS232
Optional Profibus
Ambient temperature 5...40 °C
Dimensions W x L x H (inch) 11.8 x 16.9 x 17.7
Weight (LBS) 28.6
Classification according to DIN12876-1 Classification III (FL)
Description Built-in cooling coil for tap water connection for temperature applications below or near ambient temperatures are integrated.
Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female)
Cooling coil integrated
Bath tank Stainless steel
Power requirement V / Hz / A 115/60/9 Additional voltage versions available

Characteristics

Display 
Several values at a glance
Several values at a glance
Large Multi-Display (LED), easy to read across the room, for actual value and up to 3 setpoints, warning functions, high temperature cut-off, selected pump stages (resolution 0.01/0.1 °C)
Operation 
Comfortable and detailed
Comfortable and detailed
Comfortable keypad with additional menu functions for pump stages, calibration, control parameters, programmer, warnings, etc.
Temperature Control
Highly precise
Highly precise
PID Temperature control with drift compensation and adjustable control parameters, temperature stability ±0.01...±0.02 °C
Highest measuring accuracy
Highest measuring accuracy
Absolute Temperature Calibration’ for manual compensation of a temperature difference, 3-point calibration
Technical Features
Clever pump system
Clever pump system
Reliable and consistent pump capacity, electronically adjustable pump stages
Serial connection
Serial connection
RS232 interface for PC connection, e.g. for data communication and recording of measured values
Warning & Safety Functions
Early warning system for low liquid level
Early warning system for low liquid level
Maximum safety for applications, optical and audible alarm, allows user to refill bath fluid before the unit shuts down
Early warning system for high/low temperature limits
Early warning system for high/low temperature limits
Maximum safety for applications, optical and audible alarm, convertible to automated cut-off function
Enhanced protective functions 
Enhanced protective functions 
Maximum safety, adjustable high temperature cut-off or dry-running protection, additional display of setpoints permits easy and precise adjustments
For flammable bath fluids
For flammable bath fluids
Classification III (FL) according to DIN 12876-1

Other characteristics

For temperature applications near or below ambient temperature: use a cooling coil or JULABO immersion cooler. Low tap water consumption using the MVS controller and solenoid valve (accessories).

Technical changes without prior notification.
Images may deviate from the original.

We would be pleased to submit a non-binding offer for the selected product or answer all pertinent questions.

click here for quotation request MA-12
 

Contact

JULABO USA Inc.
884 Marcon Boulevard
Allentown, PA 18109
Phone: 610-231-0250
Phone: 800-458-5226
(Toll-Free)
sales@julabo.us
www.julabo.com

Contact form

Accessories

Available voltage versions

Model: MA-12
Order No.: 9153512
Heating Circulators

230 V / 50-60 Hz
100-115 V / 50-60 Hz
 

Order catalog

Catalog request
Order our new Catalog.
Catalog request