Heating Circulators

for external and internal temperature applications up to +300 °C with stainless steel bath tanks and pump connections

JULABO circulators with stainless steel bath tanks are suitable for both internal and external temperature control. They have greater power for larger and open systems, making them ideal for external temperature control. Smaller objects may be inserted directly into the circulator's bath at the same time. Models are available with a variety of bath sizes and other functional characteristics. Accessories like Pt100 sensors, heat transfer liquid, tubing, and adapters are available to facilitate connection to external systems. An integrated cooling coil enables temperature control below or near the ambient temperature.

Product overview


CORIO new
Order No. Model Working temperature
range (°C)
Temperature stability
(°C)
Heating capacity (kW) Pump capacity flow rate (l/min) Pump pressure (psi) Comparison
9012504 CORIO CD-BC4 +20 ... +150 ±0.03 1 15 5.08
9012506 CORIO CD-BC6 +20 ... +150 ±0.03 1 15 5.08
9012512 CORIO CD-BC12 +20 ... +150 ±0.03 1 15 5.08
9012526 CORIO CD-BC26 +20 ... +150 ±0.03 1 15 5.08

TopTech
Order No. Model Working temperature
range (°C)
Temperature stability
(°C)
Heating capacity (kW) Pump capacity flow rate (l/min) Pump pressure (psi) Comparison
9153504 MA-4 +20 ... +200 ±0.01 1 11-16 3.3-6.5
9153506 MA-6 +20 ... +200 ±0.01 1 11-16 3.3-6.5
9153512 MA-12 +20 ... +200 ±0.01 1 11-16 3.3-6.5
9153526 MA-26 +20 ... +200 ±0.01 1 11-16 3.3-6.5
9162504 ME-4 +20 ... +200 ±0.01 1 11-16 3.3-6.5
9162506 ME-6 +20 ... +200 ±0.01 1 11-16 3.3-6.5
9162512 ME-12 +20 ... +200 ±0.01 1 11-16 3.3-6.5
9162526 ME-26 +20 ... +200 ±0.01 1 11-16 3.3-6.5

HighTech
Order No. Model Working temperature
range (°C)
Temperature stability
(°C)
Heating capacity (kW) Pump capacity flow rate (l/min) Pump pressure (psi) Comparison
9212504 HE-4 +20 ... +250 ±0.01 1 22-26 5.8-10.2
9252506 SE-6 +20 ... +300 ±0.01 3 22-26 5.8-10.2
9252512 SE-12 +20 ... +300 ±0.01 3 22-26 5.8-10.2
9252526 SE-26 +20 ... +300 ±0.01 3 22-26 5.8-10.2
9312504 HL-4 +20 ... +250 ±0.01 1 22-26 5.8-10.2
9352506 SL-6 +20 ... +300 ±0.01 3 22-26 5.8-10.2
9352512 SL-12 +20 ... +300 ±0.01 3 22-26 5.8-10.2
9352526 SL-26 +20 ... +300 ±0.01 3 22-26 5.8-10.2