Description
Cryo-Compact Circulator for internal and external temperature applications
 
The new CF series offers compact refrigerated/heating circulators. With small overall dimensions the units can even be placed on a very small surface or within a complex installation. All models offer a heating capacity of 2 kW and classification 3 according to DIN12876-1. The maximum ambient temperature of +40°C as well as a ventilation air cooling allow installing the units very closely side by side with other units or directly under a fume hood. Furthermore all the models feature pump connections for external temperature applications and a bath opening for temperature control of small objects directly in the circulator bath. Wetted parts are made of high quality stainless steel or plastic. The instruments provide a reliable Microprocessor electronics with high temperature stability as well as warning and safety functions. 
 
Advantages
o Ergonomic design and easy operation
o Small overall dimensions for lowest space requirement
o Splash-proof keypad
o Bright VFD display and interactive LCD dialog display
o Highly precise ICC cascade temperature control
o RS232/RS485 interface for PC connection
o Electronically adjustable pump stages
o External Pt100 sensor connection
o Integrated programmer with 6x60 program steps
o Early warning system for low liquid level
o 3-point calibration
o TCF Temperature Control Features
o Adjustable high temperature cut-off
o Classification 3 according to DIN12876-1
o Pump connections for external temperature applications
o Bath opening for temperature control of small objects in the bath
o Front drain
 
Technical Specifications
Working temperature range -30 ... 200 °C   
Temperature control ICC 
Temperature stability ±0.02 °C
Display VFD + LCD    
Display resolution 0.01 °C
Integrated programmer available 
Heater capacity 2000 W   
Cooling capacity
20   0   -20             °C
320   250   150             W
Refrigerant R134a 
Pump capacity Pressure:   10.2 psi   
Suction:   5.8 psi
Flow rate: 22-26 l/min
Digital interfaces RS232, RS485 
External Pt100 sensor connection available
Bath opening / bath depth (W x L / D) 6.3 x 1.2 / 5.5 inches
Filling volume 3.5 Liters
Dimensions (W x L x H) 9.5 x 18.1 x 15.8 inches
Weight 77 lbs
Ambient temperature 5…40 °C
Classification according to DIN 12876-1 3 (FL) 
 
Miscellaneous
Included: 2 each barbed fittingsfor tubing 8 and 12 mm inner dia. (pump connections M16x1 male)