JULABO - Innovative Temperature Technology

Contact  |  Sitemap  |  News  |  Search  |  International  |  Imprint

 
  ü Home         Company   |   Products    |   Services
Product search
 

 

Company
Products
  Product Selection
  Product News
  Product Search
  Product Comparison
  Refurbished Units
  Accessories
   
Services
 
 
 
 

 




 
Product News
 

New F250 EcoChiller
The new F250 EcoChiller by JULABO is a very compact, budget-priced and user-friendly recirculating cooler designed especially for routine application in day-to-day laboratory work. The unit cools with a closed circuit and uses only between one and 2 liters of refrigerant. The working temperatures range from +5°C to +40°C with a temperature stability of ±0.5°C (PID-control). The easily adjustable pump has a pressure capacity of 0.35 bar with a minimum flow rate of 15 l/min. Additional features include a splash-proof keypad, LED temperature display, filling nozzle on top of the unit as well as a filling level indicator. Thanks to its small foot print and the frontal vents the unit is ideal for flexible laboratory applications and provides optimal process stability.
 
The F250 cools efficiently, reduces operational costs and protects the environment by saving expensive tap water. Due to its low purchase price the unit will amortize itself in no time.

 
 

JULABO’s New Circulator Program
JULABO is pleased to introduce its new program of heating and refrigerated circulators. The three categories Economy, TopTech and HighTech offer solutions for every temperature control application in research and industry. A selection of 120 models for working temperatures from -95 to 400 °C is available. The broad product range allows users to select models specific to their application requirements; from economic models for routine applications to powerful units with top-level features for highly demanding purposes. All models are equipped with a new, intuitive operating interface with user guidance. The new design allows users to interface with the circulators using fewer keys affording an easy, consistent operation across the model range. Users will also notice the displays – they are extra bright and can be easily read from a long distance, at an angle and in very bright surroundings. The configuration menus have descriptive scrolling text making it easy to set the various functions. More improvements have been implemented internally including: temperature calibration and a timer on the economic EH models; temperature display with a resolution of 0.01 °C on the „TopTech“ series; warning and error messages reveal additional help text; and a gradient function (preset increase) in the integrated programmer of the „HighTech“ series. In addition the units feature innovative functions including; early warning systems for low liquid level and temperature limits, adjustable pump capacities, temperature calibration and much more. The new program includes two new sensors for pressure and flow measurements. Measurement data is displayed directly on the circulator or can be read and processed via a RS232 interface. JULABO takes environmental responsibility seriously and is pleased to announce the availability of refrigerated circulators with natural refrigerants.



Highly Dynamic Temperature Control Systems
JULABO’s new product series „Presto PLUS“ offers highly dynamic temperature control systems for demanding, external temperature control. „Presto PLUS“ systems are used primarily for the temperature control of jacketed reaction vessels, autoclaves and reactor systems. The large heating and cooling capacities combined with state-of-the-art control technology and small liquid volumes provide short heat-up and cool-down times for fast compensation of exothermic and endothermic reactions. The closed-system design permits a wide range of working temperatures without changing the bath fluid while at the same time preventing fumes and odors. The closed-system prevents the oxidation of bath fluid resulting in a prolonged bath fluid lifetime when compared with open air circulators. This feature also prevents condensation and ice build-up at low working temperatures. The „Presto PLUS“ series includes 6 models in different performance classes with cooling capacities up to 7 kW, heating capacities up to 6 kW and pump capacities up to 30 l/min. Working temperatures range from -80 to 250 °C depending on the model. All models feature a removable control which enables remote operation of units under fume hoods. In addition the units offer extensive features with analog and digital interfaces, automatic filling and degassing functions, pull-out handles, wheels and numerous warning, protection and monitoring functions.


 

New Services at JULABO
JULABO is pleased to announce additional service products. When purchasing new temperature control equipment, the customer can now choose additional services including maintenance contracts, IQ/OQ documentations, user training, calibration certificates as well as rental equipment and various on-site services. We provide world-wide post sales support through a network of divisions and service partners. Our team of expert technicians and JULABO-certified repair specialists know your product and provide advice and quality repair services using genuine JULABO replacement parts. Contact JULABO today to compile your individual full-service-package.

 

 

EasyTEMP Software: Version 3.0 now available
A new version of the JULABO Software EasyTEMP is now available. The new software program controls and monitors JULABO temperature control instruments via PC. The software offers varied functions to view and record temperature, and time dependant processes. The new version (3.0) was completely revised. The connection to laboratory instruments can be established not only via RS232/RS485 and profibus but also wirelessly. The EasyTEMP ‘Professional’ software supports the new WirelessTEMP products. Wireless communication can be easily established with the USB stick inserted into the PC and a transmitter connected to the JULABO instrument. The operating interface of the software was improved. Now each connected instrument has its own window with individual settings and its own diagram function for graphic display of measurement values. If required the measurement values can be saved and evaluated, for example in Microsoft Excel™. The programmer for temperature profiles can be set down to the second and supports the realization in an endless loop. The behavior characteristics of each unit after the run of a profile can now be set individually. As an additional improvement temperatures now can be changed from Celsius (°C) to Fahrenheit (°F) independently from the connected equipment. The EasyTEMP software is available in two version; the basic version of EasyTEMP supports applications with one JULABO unit and can be downloaded free of charge on www.julabo.de. The professional version “EasyTEMP Professional” features additional functions communicating with up to 24 units simultaneously interfacing other instruments, for example mixers, data loggers and various measurement instruments not to mention the wireless capabilities.


 

   
WirelessTEMP - The new Solution for Wireless Monitoring and Control of JULABO Temperature Control Instruments via PC or Remote Control
 
The 'WirelessTEMP' series of products gives you a variety of ways to communicate with up to eight JULABO temperature control instruments using a PC or the JULABO 'Remote Control'. 'WirelessTEMP' works with virtually all JULABO instruments equipped with an RS232 interface. Intelligent technology makes it easy to get started. Just switch on the system and connections will be established automatically. With 'WirelessTEMP Configurator' software, users can set up even complex networks with several separate, independent groups of instruments. This enables disturbance-free operation in neighboring laboratories.

More information about 'WirelessTEMP'...

 
 

    

 


Copyright © 2012 JULABO USA, Inc.

Company   |   Products   |   Services   |   Sitemap   |   Home