JULABO - Innovative Temperature Technology

Contact  |  Sitemap  |  News  |  Search  |  International  |  Imprint

 
  ü Home         Company   |   Products    |   Services
Product search
 

 

Company
  News
  Contact
  Company History
  Subsidiaries
  Distributors
  Exhibitions
  Guests & Visitors
  Quality
  Environment
  Career at JULABO
  Customer Survey
  Legal
   
Products
Services
   
 
 
 
 

 



News

August 7, 2009  New JULABO 2010 Catalog available
JULABO is releasing the new 2010 Catalog 'Temperature Control Solutions for Science, Research and Industry'. The completely revised 136 page catalog covers the entire product range for temperature control technology and highlighting new products and extensive services. Call 800-458-5226 or click here to obtain the temperature control catalog.
 

Catalog request form
Catalog as PDF Download

 

August 3, 2009  Showing leadership in environmental protection
Being green is nothing new at JULABO, but now the company has received official recognition for its policies. In early 2008 Managing Director Markus Juchheim accepted the EMAS certificate from Tanja Goenner, Environmental Minister of the German state of Baden-Württemberg. By participating in EMAS, JULABO voluntarily agrees to inspections by environmental specialists who evaluate the company’s dedication to environmental protection. Participating firms must also commit to long-term goals related to environmental management. The EMAS certificate simultaneously indicates fulfillment of the globally recognized EN ISO 14001 environmental standard. EMAS is the highest European recognition for systematic environmental protection in a company's operations. JULABO is a family-run corporation that has practiced a culture of responsibility towards its stakeholders and the natural environment since its founding. Innovation, efficiency, and environmental stewardship are three pillars of the organization. JULABO’s commitment to the environment starts with development and production of its products. These products provide scientists with ecological solutions to laboratory requirements. At the end of the product lifecycle, JULABO instruments can be effectively recycled, making the company a pioneer in the temperature-control industry. By investing in a photovoltaic system and an innovative geothermal heating system, the company has found a way to significantly reduce future energy expenses while simultaneously reducing its CO2 emissions.


August 3, 2009  Think Green
Currently many areas of the United States are faced with severe water shortages! Lakes and rivers are drying up; crops and livestock are in jeopardy, yet in many labs water is being wasted as it has been done for the past decades. From a simple rotary evaporator to a large laser system, much of the lab equipment is still connected to tap water for cooling purposes. The loss of water from the tap to the drain impacts the environment as well as overhead with the increasing cost of water. JULABO Chillers are in any application will help conserve our precious water and the cost of one of these chillers or recirculators can often be recouped in one year! At the same time a precise temperature control is already part of the package. There are many different types of circulators, baths and chillers that can perform in multiple operations of different tasks. JULABO celebrated its 40th anniversary in 2007 and continues maintaining the same two key deeds of innovation and customer service. Contact your local JULABO representative for further details.
 

May 11, 2009  JULABO’s New Circulator Program
JULABO is pleased to introduce its new program of heating and refrigerated circulators. The three categories Economy, TopTech and HighTech offer solutions for every temperature control application in research and industry. A selection of 120 models for working temperatures from -95 to 400 °C is available. The broad product range allows users to select models specific to their application requirements; from economic models for routine applications to powerful units with top-level features for highly demanding purposes. All models are equipped with a new, intuitive operating interface with user guidance. The new design allows users to interface with the circulators using fewer keys affording an easy, consistent operation across the model range. Users will also notice the displays – they are extra bright and can be easily read from a long distance, at an angle and in very bright surroundings. The configuration menus have descriptive scrolling text making it easy to set the various functions. More improvements have been implemented internally including: temperature calibration and a timer on the economic EH models; temperature display with a resolution of 0.01 °C on the „TopTech“ series; warning and error messages reveal additional help text; and a gradient function (preset increase) in the integrated programmer of the „HighTech“ series. In addition the units feature innovative functions including; early warning systems for low liquid level and temperature limits, adjustable pump capacities, temperature calibration and much more. The new program includes two new sensors for pressure and flow measurements. Measurement data is displayed directly on the circulator or can be read and processed via a RS232 interface. JULABO takes environmental responsibility seriously and is pleased to announce the availability of refrigerated circulators with natural refrigerants.


May 11, 2009  Highly Dynamic Temperature Control Systems
JULABO’s new product series „Presto PLUS“ offers highly dynamic temperature control systems for demanding, external temperature control. „Presto PLUS“ systems are used primarily for the temperature control of jacketed reaction vessels, autoclaves and reactor systems. The large heating and cooling capacities combined with state-of-the-art control technology and small liquid volumes provide short heat-up and cool-down times for fast compensation of exothermic and endothermic reactions. The closed-system design permits a wide range of working temperatures without changing the bath fluid while at the same time preventing fumes and odors. The closed-system prevents the oxidation of bath fluid resulting in a prolonged bath fluid lifetime when compared with open air circulators. This feature also prevents condensation and ice build-up at low working temperatures. The „Presto PLUS“ series includes 6 models in different performance classes with cooling capacities up to 7 kW, heating capacities up to 6 kW and pump capacities up to 30 l/min. Working temperatures range from -80 to 250 °C depending on the model. All models feature a removable control which enables remote operation of units under fume hoods. In addition the units offer extensive features with analog and digital interfaces, automatic filling and degassing functions, pull-out handles, wheels and numerous warning, protection and monitoring functions.


 

May 11, 2009  New Services at JULABO
JULABO is pleased to announce additional service products. When purchasing new temperature control equipment, the customer can now choose additional services including maintenance contracts, IQ/OQ documentations, user training, calibration certificates as well as rental equipment and various on-site services. We provide world-wide post sales support through a network of divisions and service partners. Our team of expert technicians and JULABO-certified repair specialists know your product and provide advice and quality repair services using genuine JULABO replacement parts. Contact JULABO today to compile your individual full-service-package.

 

 

May 11, 2009  EasyTEMP Software: Version 3.0 now available
A new version of the JULABO Software EasyTEMP is now available. The new software program controls and monitors JULABO temperature control instruments via PC. The software offers varied functions to view and record temperature, and time dependant processes. The new version (3.0) was completely revised. The connection to laboratory instruments can be established not only via RS232/RS485 and profibus but also wirelessly. The EasyTEMP ‘Professional’ software supports the new WirelessTEMP products. Wireless communication can be easily established with the USB stick inserted into the PC and a transmitter connected to the JULABO instrument. The operating interface of the software was improved. Now each connected instrument has its own window with individual settings and its own diagram function for graphic display of measurement values. If required the measurement values can be saved and evaluated, for example in Microsoft Excel™. The programmer for temperature profiles can be set down to the second and supports the realization in an endless loop. The behavior characteristics of each unit after the run of a profile can now be set individually. As an additional improvement temperatures now can be changed from Celsius (°C) to Fahrenheit (°F) independently from the connected equipment. The EasyTEMP software is available in two version; the basic version of EasyTEMP supports applications with one JULABO unit and can be downloaded free of charge on www.julabo.de. The professional version “EasyTEMP Professional” features additional functions communicating with up to 24 units simultaneously interfacing other instruments, for example mixers, data loggers and various measurement instruments not to mention the wireless capabilities.

 

March 26, 2008  New Product Series for wireless Monitoring and Control of JULABO instruments
The 'WirelessTEMP' series of products gives you a variety of ways to communicate with up to eight JULABO temperature control instruments using a PC or the JULABO 'Remote Control'. 'WirelessTEMP' works with virtually all JULABO instruments equipped with an RS232 interface. Intelligent technology makes it easy to get started. Just switch on the system and connections will be established automatically. With 'WirelessTEMP Configurator' software, users can set up even complex networks with several separate, independent groups of instruments.    read more...

February 14, 2008  New Catalog 'North America 2008/2009' including new products
The
new JULABO catalog 'North America 2008/2009' is now available and offers solutions for temperature applications ranging from -95...+400°C. The catalog contains every product within the JULABO range, including the new Recirculating Coolers of the 'FL‘ series and the new 'CF‘ series with four Cryo-Compact Circulators. Additionally the catalog contains the complete range with Heating and Refrigerated Circulators, Calibration Baths, High Dynamic Temperature Control Systems, Immersion Circulators, Water Baths and Shaking Water Baths, Laboratory Temperature Controllers, Programmers as well as the ‘EasyTemp‘ software solutions and a variety of useful accessories. Further sections showing products for special applications, background information and useful ideas concerning applications.
Order form  
JULABO North America 2008/2009 (PDF, 4.9 MB)

October 9, 2006  JULABO – Now from Coast to Coast
JULABO USA, Inc. announced today that it is expanding from coast to coast. The company has launched a BRAND NEW facility on the United States west coast, JULABO West, located in Vista, California. The current facility, JULABO USA, Inc. located in Allentown, Pennsylvania, will now be recognized as JULABO East.
 
Due to considerable demand, JULABO has invested in this new facility which will increase production by an additional 15,000 sq. ft. This Southern Californian facility is the new Presto factory. The building is already fully staffed with experienced sales, customer service, technical service, production, QA and engineering departments.
 
Establishing this additional factory will allow JULABO to focus on their largest asset – the customer. JULABO will continue to provide their high quality equipment, maintain and improve their already superior customer support and service, increase available stock, and shorter delivery times.


New facility located in Vista, California
 
 
JULABO - the innovator of liquid temperature control equipment ranging from -95°C to +350°C strongly focuses on the customers’ individual needs. With the current growth and demand, JULABO will be able to continue to provide temperature solutions to all industries while continuing to strengthen its presence from… 'Coast to Coast… When Temperature Matters... The Most'!
 
JULABO would like to sincerely thank all of their loyal customers for being supportive during the expansion!

JULABO EAST
754 Roble Road, Suite 180
Allentown, PA 18109
 
            JULABO WEST
2575 Pioneer Avenue, Suite 102
Vista, CA 92081
Phone:     610-231-0250
Phone:   800-458-5226 (Toll-Free)
Fax:   610-231-0260
 
Phone:     760-842-8010
Phone:   888-274-3998 (Toll-free)
Fax:   760-842-8015

 


May 10, 2006  New Recirculating Coolers/Chillers ‚FL Series‘
At Achema JULABO will introduce the FL line, the latest generation of chillers for routine cooling applications in laboratories and industry. 20 different models with numerous features and air or water cooled options offer the ideal solution for any application. Compact chillers with cooling capacities up to 1.7 kW are ideal for typical lab applications as they can be placed under or on top of the lab bench. More powerful models with up to 11 kW of cooling capacity are designed with small footprints. The working temperature range covers –20°C to +40°C, the PID controller enables a temperature stability of ±0.5°C. Four different pump types with flow rates of up to 60 l/min respectively and 6 bar pressure will meet any requirement. All units have an LED temperature display integrated into a splash water proof keypad for easy cleaning. An RS232 interface as well as an analog alarm output are located on the front panel and the lift-up cover placed on the top gives easy access to the filling port. An additional hinged tray serves as a compartment for the operating manual and other documents. The removable venting grid allows for easy cleaning of the condenser. All models include an easily visible level indicator. Models with a pump pressure of more than 1 bar additionally display the pump pressure on a gauge and feature a pump pressure bypass to adjust the pump capacity. Venting slots are exclusively located on the front and back and therefore allow placing the units directly next to each other. 
read more...

May 10, 2006  New Cryo-Compact Circulators ‚CF Series‘
With the new CF series JULABO presents four compact refrigerated/heating circulators. With dimensions of only 24 x 46 x 40 cm and 28 x 46 x 46 cm (W x L x H) the units can even be placed on a very small surface or within a complex installation. Depending on the model cooling capacities of up to 470 Watt can be reached. The working temperature range reaches from –40°C to +200°C. The ‚HighTech‘ models CF31 and CF41 utilize an intelligent and self-optimizing ICC cascade temperature control with a stability of ±0.02°C. These models also feature an electronically adjustable pump capacity with a flow rate of 22-26 l/min respectively a pressure/suction capacity of 1.1 bar. Further features are a VFD display and an interactive LCD display with user guide, 3-point calibration, connection for Pt100 external sensor, RS232/485 interface, integrated programmer as well as early warning system for low liquid level. The CF30 and CF40 models of the ,Economy‘ series are provided with a PID temperature control, reaching a stability of ±0.03°C. The temperature is indicated on an LED display. The pressure pump capacity of the ‚Economy‘ series is 15 l/min respectively 0.35 bar. All four models offer a heating capacity of 2 kW and safety class 3 according to DIN12876-1. The maximum ambient temperature of +40°C as well as a ventilation air cooling allow installing the units very closely side by side with other units or directly under a fume hood. Furthermore all the models feature pump connections for external temperature applications and a bath opening for temperature control of small objects directly in the circulator bath. 
read more...

March 27, 2006  New powerful Highly Dynamic Temperature Control System 'Magnum 91'
With the new ,Magnum 91‘ JULABO offers a powerful highly dynamic temperature control system for demanding external temperature applications, like e.g. temperature control of reactors up to 50 litres. The advantages are rapid heat-up and cool-down within the working temperature range from –91 to +250°C as well as an immediate control of exothermic and endothermic reactions. The typical applications include control of jacketed reactor vessels, reactor systems, pilot plants and reaction blocks as well as polymerization, polycondensation, distillation and synthesis chemistry. The water-cooled unit offers a heating capacity of 6 kW as well as a cooling capacity of 5 kW at +20°C, 4 kW at 40°C, 2.5 kW at –60°C and 0.6 kW at –80°C. The circulation pump is electronically adjustable and reaches a flow rate of 24 to 35 l/min resp. a pressure of 0.8 to 2.2 bar. With the intelligent ICC cascade temperature control rapid results with high precision are reached. The temperature stability is between +/-0.05 and +/-0.2°C. For time and temperature depending processes there is an integrated programmer with 6x60 program steps. Additionally the system has a closed tempering circuit, here the advantages are a reduced oxidation and a longer lifetime of the bath fluid – unpleasant odors and vapors do not get outside. Further features are an RS232/RS485 interface, a connection for external Pt100 sensor, an early warning system for temperature limit values as well as a keypad, which is divided into two, with VFD- and LCD display for user input. 
read more...

 
 

Copyright © 2010 JULABO USA, Inc.

Company   |   Products   |   Services   |   Sitemap   |   Home